CARE OF YOUR MOTORHOME
12V TROUBLESHOOTING CHART (continued)
230V TROUBLESHOOTING CHART
Symptom Cause Remedy
230V system inoperative No site power Check site supply
RCD/MCB switches tripped out Reset circuit breakers
RCD/MCB keeps tripping Fault on 230V supply Check supply including polarity
out Faulty appliance Turn off all appliances, reset
circuit breakers, turn on
appliances until fault occurs.
Isolate faulty appliance
Overload on current 10A maximum available do not
consumption by appliance use appliance
Water heater does not No power Switch on MCB isolator switch
operate on 230V and check 6amp MCB is on
Water heater does not Overtemperature trip activated Reset thermal cut-out (refer to
operate on 230V operating instructions)
Battery charger does not Charger switched off Switch on MCB isolator switch
operate and check 6amp MCB is on
Refrigerator does not operate Switch on refrigerator Check position of thermostat
on 230V thermostat dial not ‘on’ dial
Element fault Refer to dealer
Cooker Hotplate Not heating up Make sure 230V is switched on.
at isolator
Check trip switch
Check 10amp MCB is on
Symptom Cause Remedy
Water Heater not Fuse 3 blown Find fault and replace fuse with
operating/cuts out same rating
Low battery charge Recharge battery
Unit fault Refer to dealer
Cooker ignition not operating Fuse 3 blown Find fault and replace fuse with
same rating
Spark unit fault Refer to dealer
Fault on cooker unit Refer to dealer
Fridge gas ignition not Fuse 3 blown Find fault and replace fuse with
operating same rating
Ignition control switch fault Refer to dealer
Fridge ignition switch flashes Fault on fridge unit Refer to dealer
but gas does not ignite
Ignition can be heard to be Faulty fridge ignition switch Refer to dealer
sparking but no flashing on
fridge switch
Fridge does not operate on Fuse 8 blown Find fault and replace fuse with
12V when engine is running same rating
Fault on fridge relay Refer to dealer
Fault on fridge unit Refer to dealer