Operating instructions
10-8
CARE OF YOUR MOTORHOME
WATER TROUBLESHOOTING CHART
Symptom Cause Remedy
Continuous running of 1. No water 1. Fill tank
water pump 2. Major leak 2. Switch off immediately and
check system
Intermittent operation of water Minor leak in water system Check push fit joints
pump
Intermittent operation of water Water pump pressure release No action - part of pump design
pump 20 second cycle valve reasserting itself
(approx).
Water pump does not operate Fuse 4 blown Find fault and replace fuse with
same rating
Water gauge does not Probe fault Refer to dealer (check probe
operate connections)
No hot water (mains system) Water heater tripped Check and press re-set button
No hot water (gas system) Gas module not lighting Refer to dealer
No hot water (gas system) Igniter not working Check 12V switched on
Slow drainage from Blocked breathers in waste tank Drop tank and clear breathers
sink/shower tray
Tip-up handbasin slow to Blocked drain hole Remove basin and clear
drain
Unsatisfactory operation of Filter blocked Clean filter
water pump