Some models may support this function. Take 16 CH alarm inputs and 1 CH alarm output for 
example. 
Alarm Input: 
Alarm IN 1~16 are 16 CH alarm input interfaces. There are no type requirements for sensors. 
NO type and NC type are both available.   
The way to connect sensor and the device is as shown below: 
The alarm input is an open/closed relay. If the input is not an open/closed relay, please refer to 
the following connection diagram: 
Alarm Output: 
The way to connect alarm output device: 
Pull out the green terminal blocks and loosen the screws in the alarm-out port. Then insert the 
signal  wires of  the  alarm output  devices into  the  port  of NO  and  COM  separately.  Finally, 
tighten the screws. Provided that the external alarm output devices need power supply, you can 
connect the power supply as per the following figures. 