User guide

DH Dual Hall Effect Pickup
Installation and Technical Data Guide
AW Gear Meters Franksville, WI Phone: (262) 884-9800 Fax: (262) 884-9810
Email: awinfo@aw-lake.com www.awgearmeters.com
Rev 06/10
Description:
The DH Dual Hall Effect Pickups are microprocessor-based sensors for use with the JV-CG and JV-KG series
of positive displacement flow meters. The DH sensors can detect both uni- and bi-directional flow. The sensors’
mode of operation is determined by an output selection switch located inside the housing. The DH detects the
rotation of the flow meter’s gears and emits a frequency signal proportional to flow. The output signal is a
square wave pulse which has a duty cycle of approximately 50%.
DH signal outputs are protected with a self-resetting fuse. This fuse has a 50mA nominal trip point. When a trip
occurs, turn off power to the sensor and remove output load to reset fuse. The sensor has two different output
configurations: sinking output and sourcing output.
The DH sensor circuit board is equipped with a red and green LED. The red LED is a status LED which, when
the sensor is operating properly, will flash once every 2 seconds. The green LED indicates the pulse of the
input signal. Note that signals above 20Hz will look as solid green.
Installation:
Ensure that the flowmeter sensor cavity is free of debris prior to installing pickup
Make sure the sensor mounting screws line up with the sensor mounting holes. If they do not, remove and
rotate the sensor 180°
Sensor is equipped with an output test feature for readouts before initial running of your system
TEST FEATURE:
Note: Power must be cycled for new setting to take effect
Switch setting 8 will cause the pick-up to output a 10 Hz (+/- 20%) Phase = +90 deg pulse output, simulating
low flow conditions without flow through your meter.
Switch setting 9 will cause the pick-up to output a 250 Hz (+/- 20%) Phase = -90 deg pulse output, simulat-
ing medium flow conditions without flow through your meter.
NOTE: WIRING SHOULD BE INSTALLED BY A QUALIFIED INSTRUMENTATION TECHNICIAN
Pin Number Wire Color
Signal 2: 2 Green
Signal 1: 4 White
Ground: 5 Black
Supply Voltage: 6 Red
Wiring Color Code
Pin Number DH-A / -AA DH-B / -BB
1 NC NC
2 Output 2 Output 2
3 NC NC
4 Output 1 Output 1
5 Ground Ground
6 Supply Supply
Electrical Connection for Pin Connector
1
2
3
5
6
4
Pinout looking at male
connector on sensor
Switch Output 1 Output 2
0 Direction Signal 2
1 Signal 1 Signal 2
2 Direction Signal 1 + 2 (2x frequency)
3 Signal 1 Signal 1 + 2 (2x frequency)
4 Signal 1 (both outputs in phase)
5 Signal 2 (both outputs in phase)
6 Signal 1 + 2 (both 2x frequency & both outputs in phase)
7 Reserved
8 Test: S1 & S2 == 10 Hz (+/- 20%) Phase = +90 deg.
9 Test: S1 & S2 == 250 Hz (+/- 20%) Phase = -90 deg.
DH Operating Modes
Top view of circuit board with
view of LED’s and switch
Note: Power must be cycled for new
setting to take effect