Manual

EMO3000
OperationandProgrammingManual
32

CHA JOBTOTAL‐A JOBTOTAL‐B RATIO
01 XXXXX. XXXXX. XXX.XX
02 XXXXX. XXXXX. XXX.XX
03 XXXXX. XXXXX. XXX.XX
04 XXXXX. XXXXX. XXX.XX
05 XXXXX. XXXXX. XXX.XX
06 XXXXX. XXXXX. XXX.XX
F1=ESC F2=CHSWAP F3=DI+ F4=RES
F1=ESCreturnsyoutotheMainMenu
F2=CHSWAPshowsthenextsixchannels(712)
F3=DI+callsuptheRATESscreen
F4=RESresetstheJobTotals;theRatioresetsaccordingly
QuickProgramming
2QUICKPROGRAM
QuickProgrammingallowsyoutodisplay theFlowRatesandTotalsinthedesiredEngineeringUnits
withoutextensiveprogramming.YoucanselecttheFlowMeterandEngineeringUnitsfromame nuand
enterthemforeachchannel.
F1=ESCreturnsyoutoMainMenu
F2=MTRpagesMETERthroughthesechoices:
ZHM01
ZHM02/1
ZHM02
ZHM03
HPM15
HPM20
HPM30
***QUICKPROGRAMMING******
METER=ZHM 01 UNITS=CCM CHA=01

PRESSF5 TOENTER FORCHANNELA
PRESSF6 TOENTER FORCHANNELB
F1=ESC F2=MTR F3=UNITS F4=CHANNL
