34

F2clearsthevaluefortheselectedFluidNumber.F6entersthevaluefortheselectedFluidNumber.
VariableDescription
Thefollowingpagesdescribeeachoftheprogrammablevariables.Alsoincludedisinformationfor
programmingviatheRS232serialportwithaPCorPLC.Seepage47fordetailsonSerial
Communicationprogramming.
FlowrateAmellow
ThisistheflowrateforchannelAwithadigital
filterapplied.Theinputforthissignalispin4 onthe
terminalstrip.
USEDIN: Allmodes.
RELATEDVARIABLES: SampleamountA/engineeringunitsforRate.
HEXADDRESS: 0020HEX‐‐‐‐‐‐>sameaddressusedinEMO2000.
BYTES: 4BytesDEFAULT =xxx
ASCform
COMMAND:
reading=100;writing=500;Eisengi neeringunits;Eisin
selectedengineeringunitswith unitsattached.Nis
normalizedunitsinHertzdownto1/100
th
.
FlowrateAinstantaneous
Thisisthe“raw”frequencyappliedtotheinputpin4onthebackplaneconnector.Thereisno
manipulatingtaking placetoderiveattheratevalue.Itisquitecommontousethisvaluefortheanalog
outputreflection.
USEDIN: Allmodes.
RELATEDVARIABLES: KFRA/EngineeringunitsforRate.
HEXADDRESS: 001CHEX‐‐‐‐‐‐>sameaddressusedinEMO2000.
BYTES: 4BytesDEFAULT: xxx
ASCform
COMMAND:
reading=130;writing=530;Eisengi neeringunits;Eisinselected
engineeringunitswithunitsattached.Nisnormalizedunitsin Hertz
downto1/100
th
.
TotalizerforA
ThisisthetotalizedamountA.Theinputforthissignalispin4ontheterminalstrip.