Manual

EMO3000
OperationandProgrammingManual
43

USEDIN: PIDmode.
RELATEDVARIABLES: A_KD/A_KP/A_KI
HEXADDRESS: 00DEHEX‐‐‐‐>SAMEAD DRESSASINEMO2000
BYTES: 2BytesDEFAULT:210
ASCformCOMMAND: reading=123;writing=523;EandNbothhavethesameeffect
value.Byadding/XXcr,whereXXiscolornumber(example:
#01E113/12cr),theGainfactorforthecolor12isreturned.
Omitting/XXreturns0.
mAScalerforPID
Themilliampsscalerisusedforscaling0‐20mAmpanalogsignalinput.Eachmilliampabovethemilli
ampsinoffsetrepresentsacertainamountofrequestedflowinengineeringunitsorHertz.
USEDIN: PIDmode.
RELATEDVARIABLES: mA’offset
HEXADDRESS: 01B3HEX‐‐‐‐>SAMEADDRESSASINEMO2000
BYTES: 2BytesDEFAULT:21cc/mpermA
ASCformCOMMAND: reading=126;writing=526;Ereturnstheengineering
units/mA;NreturnsHz/mA’s.
mAInOffset
Usedtoevenoutsourcesthatdonotdeliverexactly4.00mA’s.Inpractice,itreplacesaadjustment
potentiometer.
USEDIN: PIDmode.
RELATEDVARIABLES: mA’scaler
HEXADDRESS: 00E6HEX‐‐‐‐>NEWVARIABLE
BYTES: 2BytesDEFAULT:825(4.02mA)
ASCformCOMMAND: reading=124;writing=524;EreturnsthemA’svalue;Nreturns
counts.