Manual

EMO3000
OperationandProgrammingManual
44

mAOutOffset
Usedtobiastheanalogoutputsignaltoapresetlevel .Any valuefr om0.00to20 .00mA’sisvalid.The
mostcommonis4.00mA’s.
UsehigheroffsetvaluesinPIDmode,particularlyifthecrackingpressureoftheregulatorishigherthan
normal.
USEDIN: PIDand
Monitormode
RELATEDVARIABLES: mAshifter,mAgain
HEXADDRESS: 0091HEX‐‐‐‐>SAMEADDRESSASINEMO2000
BYTES: 2BytesDEFAULT:819(4.00mA)
ASCformCOMMAND: reading=111;writing=511;EreturnsthemA’svalue;Nreturns
counts.
mAGainfactor
Usedtoscaletheanalogoutputtotheexpectedinputfrequency.Thisscalingfactoronlyappliesin
monitormodeanddoesnotaffectPID.Sincethetopfrequenciesareanywherefrom3Hzto2000Hz,
therehastobeascalingpo ssibility.Applythis formulatoscalethe
gainfactorcorrectly:
GAIN=mA’sx8350/freq
where
mA’srepresentstherequestedmA’outputatthefrequency
freqisthetopfrequencyexpectedat20mA’s
Thedefaultvalue167causestheinputfr equencyof1000Hztogeneratea20.0 0 mAoutput.
USEDIN: Monitormode
RELATEDVARIABLES: mAshifter,mAgain,mApointer
HEXADDRESS: 0091HEX‐‐‐‐>SAMEADDRESSASINEMO2000
BYTES: 2BytesDEFAULT:167
ASCformCOMMAND: reading=116;writing=516;EandNreturnanintegernumber.
Notice