Step #5 Installing the Sensors 41
Installation Guide v2.3 – 5/10
Confidential and Proprietary ©2010, Awarepoint Corporation
Light Green - A FFD connected to any Bridge except the Bridge the Appliance
thinks it should be connected to. An examination of the network should reveal
why the particular Sensor(s) are attached to an "incorrect" Bridge.
Figure 59 – Sensors and Signal Strength
The lines between Sensors indicate the signal strength between them.
Green - A strong (-60 or stronger) connection. You should see very few of these
in any standard install.
Yellow - A moderate (-75 to -61) connection. Many parent-child connections
should be yellow, but few others should
Orange - A weak (-82 to -76) connection. There should be many of these
connections between non-connected sensors.
Note: You must be connected to the System Manager through the Local Network to
view this page. This page cannot be viewed when accessing System Manager through
the Network Operations Center.
Add/move Sensors until each Sensor has multiple paths back to the Bridge. The
example above shows a good mesh layout.
7.7 Deleting Unused Bridges and Sensors from System
1. Open the System Manager and login.
2. Click on the Device Management Tab.
3. Click on the Devices sub-tab.
4. Select either Bridges or Sensors.
5. To delete, highlight the appropriate MAC address and choose Delete at the
bottom of the screen. Multiple MAC addresses can be selected simultaneously
by holding the “Ctrl” key while clicking.
Use caution when purging from the system.