Product manual

6.4 Technical data
6.4.1 Technical data for 110/230 V (types S3_ _6_)
SERVOSTAR
Rated data DIM 303 306 310
Order Code S30361 S30661 S31061
Rated supply voltage
(grounded supply, phase to phase)
V~
1 x 110V
-10%
… 1 x 230V
+10%
3 x 110V
-10%
… 3 x 230V
+10%
50/60 Hz
Rated input power for S1 operation kVA 1.1 2,4 4
Max. DC bus link voltage V= 450
Rated output current (rms value, ± 3%)
at 1x110V Arms 3 3 3
at 3x115V Arms 3,5 8 10
at 3x230V Arms 3 6 10
at 1x230/240V Arms 3 4 4
Peak output current (rated current x 2 for approx. 5s, ± 3%)
at 1x110V Arms 5 5 5
at 3x115V Arms 9 15 20
at 3x230V Arms 9 15 20
at 1x230/240V Arms 9 9 9
Switching frequency of the output stage kHz 8 (16*)
Technical data for regen circuit ð p.24
Threshold for overvoltage switch-off VDC 235 / 455
Motor inductance min.
at 1x110V mH 3,7 3,7 3,7
at 3x115V mH 2,1 1,3 1,0
at 3x230V mH 4,3 2,6 1,9
at 1x230/240V mH 4,3 4,3 4,3
Motor inductance max. mH Consult our customer support
Form factor of the output current
(rated conditions, min. load inductance)
1.01
Bandwidth of current controller kHz > 1.2
Residual voltage drop at rated current V 4
Thermal dissipation, output stage disabled W 12
Thermal dissipation at rated current
(incl. PSU losses, without regen dissipation)
W35 60 90
Mechanical
Weight kg approx. 2,6
Height, without connectors mm 275 279
Width mm 70
Depth, without connectors mm 171
Depth, with connectors mm < 200
* at reduced current
SERVOSTAR
®
300 Product Manual 19
Kollmorgen 09/2006 Technical description