Product manual

6.4.2 Technical data for 400/480 V (types S3_ _0_)
SERVOSTAR
Rated data DIM 341 343 346
Order Code S30101 S30301 S30601
Rated supply voltage
(grounded supply, phase to phase)
V~
3 x 208V
-10%
… 480V
+10%
, 50/60 Hz
Rated input power for S1 operation kVA 1.2 2,5 5
Max. DC bus link voltage V= 900
Rated output current (rms value, ± 3%)
at 3x208V Arms 2 5 6
at 3x230V Arms 2 5 6
at 3x400V Arms 1,5 4 6
at 3x480V Arms 1,5 3 6
Peak output current (max. approx. 5s, ± 3%)
at 3x208V Arms 4,5 7,5 12
at 3x230V Arms 4,5 7,5 12
at 3x400V Arms 4,5 7,5 12
at 3x480V Arms 4,5 7,5 12
Switching frequency of the output stage kHz 8 (16*)
Technical data for regen circuit ð p.24
Threshold for overvoltage switch-off VDC 455 / 800 / 900
Motor inductance min.
at 3x208V mH 7,7 4,6 2,9
at 3x230V mH 8,5 5,1 3,2
at 3x400V mH 14,8 8,9 5,6
at 3x480V mH 17,8 10,7 6,7
Motor inductance max. mH Consult our customer support
Form factor of the output current
(rated conditions, min. load inductance)
1.01
Bandwidth of subordinate current controller kHz > 1.2
Residual voltage drop at rated current V 5
Thermal dissipation, output stage disabled W 12
Thermal dissipation at rated current
(incl. PSU losses, without regen dissipation)
W40 60 90
Mechanical
Weight kg approx. 2,7
Height, without connectors mm 275 278
Width mm 70
Depth, without connectors mm 171
Depth, with connectors mm < 235
* at reduced current
20 SERVOSTAR
®
300 Product Manual
Technical description 09/2006 Kollmorgen