Product manual

Technical Data:
Regen circuit Supply voltage
Rated data Dim. 110 V 230 V 400 V 480 V
303
(S30361)
Switch-on (upper) threshold of regen circuit V 200 400
Overvoltage F02 V 235 455
Regen resistor (internal) Ohm 66 66
Continuous power in regen circuit (RBint) W 20 20
Pulse power in regen circuit (RBint max. 1s) kW 0,75 3
Regen resistor (external)* Ohm 66 66
Continuous power in regen circuit (RBext) max. kW 0,3 0,3
Pulse power in regen circuit (RBext max. 1s) kW 0,75 3
306 / 310
(S30661/S31061)
Switch-on (upper) threshold of regen circuit V 200 400
Overvoltage F02 V 235 455
Regen resistor (internal) Ohm 66 66
Continuous power in regen circuit (RBint) W 50 50
Pulse power in regen circuit (RBint max. 1s) kW 0,75 3
Regen resistor (external)* Ohm 66 66
Continuous power in regen circuit (RBext) max. kW 1 1
Pulse power in regen circuit (RBext max. 1s) kW 0,75 3
341
(S30101)
Switch-on (upper) threshold of regen circuit V
400 720 840
Overvoltage F02 V 455 800 900
Regen resistor (internal) Ohm 91 91 91
Continuous power in regen circuit (RBint) W 20 20 20
Pulse power in regen circuit (RBint max. 1s) kW 2,1 7 9
Regen resistor (external)* Ohm 91 91 91
Continuous power in regen circuit (RBext) max. kW 0,3 0,3 0,3
Pulse power in regen circuit (RBext max. 1s) kW 2,1 7 9
343 / 346
(S30301/S30601)
Switch-on (upper) threshold of regen circuit V
400 720 840
Overvoltage F02 V 455 800 900
Regen resistor (internal) Ohm 91 91 91
Continuous power in regen circuit (RBint) W 50 50 50
Pulse power in regen circuit (RBint max. 1s) kW 2,1 7 9
Regen resistor (external)* Ohm 91 91 91
Continuous power in regen circuit (RBext) max. kW 1,0 1,0 1,0
Pulse power in regen circuit (RBext max. 1s) kW 2,1 7 9
* Partially other resistance values are possible. Please ask our customer support.
SERVOSTAR
®
300 Product Manual 25
Kollmorgen 09/2006 Technical description