8.3.3 Technical data for connecting cables
Further information on the chemical, mechanical and electrical characteristics of the
cables can be obtained from our customer service.
Observe the rules in the section "Conductor cross-sections" on page 22. To reach
the max. permitted cable length, you must use cable material that matches the
capacitance requirements listed below.
Insulation material
Sheathing PUR (polyurethane, code 11Y)
Core insulation PETP (polyesteraphthalate, code 12Y)
Capacitance
Motor cable less than 150 pF/m
Resolver/Encoder cable less than 120 pF/m
Technical data
The brackets in the core definition indicate the shielding.
All cables are suitable for use as trailing cables.
The technical data refer to use as moveable cables.
Operating life : 1 million bending cycles
Cores
[mm²]
max.
length
[m]
Use for
Operating
temp. range
[°C]
Outside
diameter
[mm]
Bending
radius
[mm]
(4x1.0) 50* motor / power -30 / +80 10 100
(4x1.5) 50* motor / power -30 / +80 10.5 105
(4x1.0+(2x0.75)) 50* motor incl. brake -30 / +80 10.5 105
(4x1.5+(2x0.75)) 50* motor incl. brake -30 / +80 11.5 120
(4x(2x0.25)) 100* Resolver -30 / +80 6.9 70
(7x(2x0.25)) 50* Encoder -30 / +80 7.7 90
* Danaher Motion North America supplies cables up to 39 meters
* Danaher Motion Europe supplies cables up to max. length.
Motor cables longer than 25m require the use of a motor choke 3YLN (see p.103).
SERVOSTAR
®
300 Product Manual 35
Kollmorgen 09/2006 Electrical installation