8.7.2 24V auxiliary supply (X4)
— External 24V DC power supply, electrically isolated, e.g. via an isolating transformer
— Required current rating ð p.19
— Integrated EMC filter for the 24V auxiliary supply
8.7.3 DC bus link (X8)
Terminals X8/1 (-DC) and X8/3 (+RBext). Can be connected in parallel, whereby the
regen power is divided between all the amplifiers that are connected to the same DC bus
link circuit.
Only servo amplifiers with mains supply from the same mains (identical mains
supply voltage) may be connected by the DC bus link.
40 SERVOSTAR
®
300 Product Manual
Electrical installation 09/2006 Kollmorgen
SERVOSTAR 300
SERVOSTAR 300
SERVOSTAR 300