Operating instructions
3-2
To change a setting:
Action Key Duration Display
Enter basic programming SET P/R Will show day of week
Move to desired display UP and DOWN P/R Will increment through
arrows the displays
Enable setting to be changed SET P/R Display will fl ash
Change setting UP and DOWN P/R Value changes and
arrows continues to fl ash
Save setting SET P/R Display stops fl ashing
Return to operation REGEN P/R Normal operation display
This level of programming is accessible by pressing the SET button.
The UP and DOWN arrows will step through the settings.
Time of day
Day of week
Time of regeneration
Number of days between regeneration (99 day calendar override timer)
Amount of salt used per regeneration
System capacity
Hardness
To make changes:
• Time of day
When the Time of Day is displayed, push SET. The time will fl ash. Use the arrow buttons to increase/decrease
the time. Push SET to enter the selection.
• Days of the week
The day of the week does not have a default setting. It is entered at Power-up. To change the current day, push
SET when day of week is displayed. A fl ag will fl ash beneath the current day. Use the arrow buttons to change.
Push SET to enter the selection.
• Time of Regeneration
This is set for 2:00 AM as the default. The controller does not account for daylight savings time.
To change this setting, push SET. Use the arrow buttons to increase/decrease the time. Push SET to enter the
selection.