User's Manual Part 2

Control and Monitoring Module
The control and monitoring module interfaces with all other modules. Refer to the tables on
the following pages for specific details about the functions of this module.
ACTV - green LED that is dim during microprocessor
boot up and bright when active.
CTRS LCD - potentiometer that adjusts
level of contrast on the front panel LCD
POWER - potentiometers that set power levels
FWD - Forward power should be set to approx 100%
REFL - Reflected power should be less than 10%
EXT F- External forward power should be set to approx 100%
EXT R - external reflected power should be less than 10%
DO NOT make any adjustmens to these pots, they are set to a reference point
at the factory.
NORM and AUX - these are for future expansion and
presently not used
DIP SWITCH
1 - EXT AMP - place in on position when an external amplifier is used
2 - INT MOD - place in on position when an internal modulator is used
3- EXT IF TO MOD - external IF carrier option
4-6 spares
7-8 LANGUAGE - sets up the language of the LCD display
00 = English
01 = Portugese
10= Spanish
11=
Reset switch must be pushed anytime
dip switch settings are changed.