Installation Manual

Reader Installation
28 750.001.003
Revised June 1999
© 1999 AXCESS
TM
Inc.
Connecting the Serial Gateway to the PC
Step 1: Connect the male DB9 end of the straight-through serial
cable to the female DB9 connector at the bottom of the
Reader.
Step 2: Connect the other end of the serial cable to the PC.
Step 3: The Serial Gateway has pads so that it can be placed on
top of or next to the PC.
Step 4: Configure the communications port settings on the PC as
follows:
Baud 2400
Data Bits 8
Parity None
Stop Bits 1
Flow Control None
The Serial Gateway is a DCE (Data Circuit-terminating
Equipment) device, and data is output through a DB9
female RS-232 connector. Only the following pin
assignments are used:
Transmitted Data (pin 2)
Received Data (pin 3)
Signal Ground (pin 5)
Connecting the Serial Gateway to an FTT Reader
Step 1: Prepare a sufficient length of twisted pair wire to connect
the first Reader to the Serial Gateway.
Step 2: Insert the twisted pair wire into the terminal block labeled
FTT in Figure 11 in the Serial Gateway and run it out the
conduit chase.
Step 3: Run the twisted pair through the conduit chase of the
Reader and insert the twisted pair wire into the FTT
terminal block. You can connect up to four Readers by the
FTT terminal block in the Serial Gateway; however, we
recommend connecting only one or two. You can network
up to thirty-one Readers together by twisted pair wire.
Connecting FTT Readers to Each Other
Step 1: Prepare a sufficient length of twisted pair wire to connect
the two Readers.