Installation Manual

Configuring 3.x Reader Firmware
38 750.001.003
Revised June 1999
© 1999 AXCESS
TM
Inc.
Data Bits 8
Parity None
Stop Bits 1
Flow Control None
Step 7: Click the OK button. If you are connecting to a Serial
Reader, the HyperTerminal’s main window will display the
five-digit ID numbers for any Tags in the field. Wiegand
and FTT Readers will not output anything to the screen
unless they are placed in diagnostics mode (See the
section Toggling Between Default and Diagnostic Modes,
page 42.)
Reader Commands
The following is a list of commands that can be sent to the Reader
via the terminal application.
Code Action
* Changes the Tag version that the Reader reads.
This should be checked to ensure that the Reader is
reading the correct version of Tag. A Reader can only read
2.0 Tags or 3.x Tags; it cannot read both.
# Changes the Reader ID to eliminate the potential of cross
talk.
& Turns on/off diagnostic mode.
$ Allows the Reader to act on a 254 code in addition to its
own ID number. This is only available for Wiegand
Readers.