User's Manual

Table Of Contents
System Configuration Basics
© 2001, AXCESS Inc. 750.001.004 R0033 23
Receiving Antenna
RG-58 - 25 feet maximum
Receiver
Figure 8 Max distance between Receiver and receive antenna
Best results are achieved when the transmit antenna is no more than
50 feet from the Activator. However, distances of up to 100 feet are
possible with minimal degradation in performance. Contact Customer
Support for assistance with special installation needs.
Transmitting Antenna
RG-58 - 50 feet maximum
Activator
Figure 9 Max distance between Activator and transmit antenna
IMPORTANT!
System performance may be adversely affected if a
different cable is used, the cable length exceeds recommendations,
the cable is kinked, or the BNC connectors are improperly installed.
Basic Installation Steps
The following list shows the order in which the ActiveTag system
should be installed.
Step 1: IMPORTANT!
Bench test communications between the
ActiveTag system and the controller or device to which it
will be connected.
Step 2:
Configure the Activator – Give each Activator a unique ID
number if there will be multiple Activators on site.
Step 3:
Configure the output of the Receiver – for example, enable
Wiegand output if required. If there are multiple Activators,
program how the Receiver should respond to the Activator
ID(s).
Step 4:
Lay the entire ActiveTag system out and test the antenna
fields before permanently installing any piece of the
system.
Step 5:
Install the Activator and Receiver.
Step 6:
Install the transmit and receive antennas.