User's Manual

Table Of Contents
Configuring the Receiver
36 750.001.004 R0033 © 2001 AXCESS Inc.
Setting up a Wiegand System
Responding to Activator IDs
By default, the Receiver will only output Wiegand data from Tags
activated by Activator ID 127. To change the Activator ID, type the
new Activator ID number followed by a capital W:
<number>W
<number>W<number>W
<number>W
This is known as a Wiegand ID. The default is to only output reads
corresponding with this Activator.
To enable the Receiver to respond to multiple Activator IDs, type:
33c
33c33c
33c
The Wiegand output of the Receiver will now include all tag reads
from Activators listed as valid Activator ID’s for serial output in
addition to the Wiegand ID. See
Responding to Activator IDs
,
page 38, for the list of Activator IDs and how to configure them.
To return the Wiegand output to the single the single Wiegand
Activator ID, type:
19c
Alarm Output
By default, the Receiver does not output Tag data containing alarm
codes from Panic or Tamper Tags via the Wiegand port. To enable
alarm data output, type:
26c
26c26c
26c
To disable alarm data output (default state), type:
12c
12c12c
12c
Setting up a Serial or LAN System
Setting the Baud Rate
The following commands are available for configuring the Receiver’s
serial port:
Command Action
23c
23c23c
23c
Set the baud rate to 4800.
24c
24c24c
24c
Set the baud rate to 9600. Default.
25c
25c25c
25c
Set the baud rate to 19200 for NIU connections.
Serial Output
The default format for Tag data sent out the serial port is:
R R R A A A F F F T T T T T LF CR
R R R A A A F F F T T T T T LF CRR R R A A A F F F T T T T T LF CR
R R R A A A F F F T T T T T LF CR