Configuring the Receiver
© 2001, AXCESS Inc. 750.001.004 R0033 37
Where
R R R
R R RR R R
R R R
is the Receiver ID,
A A A
A A AA A A
A A A
is the Activator ID,
F F F
F F FF F F
F F F
is
the facility code,
T T T T T
T T T T TT T T T T
T T T T T
is the Tag ID number,
CR
CRCR
CR
is Carriage
Return, and
LF
LFLF
LF
is Line Feed.
To make the Receiver backwards compatible with AXCESS NT132
systems, type:
36c
36c36c
36c
The serial output will now have the short format:
A A A F F F T T T T T LF CR
A A A F F F T T T T T LF CRA A A F F F T T T T T LF CR
A A A F F F T T T T T LF CR
To return to the long format out (default), type:
21c
Optimizing Serial Output
The speed at which the Receiver processes data can be maximized
by eliminating the extra steps required to output Wiegand data and
check TTL output control settings.
To optimize serial output, turn off the Receiver’s Wiegand output by
typing:
29c
29c29c
29c
To restore Wiegand output (default), type
15c
If your installation does not require TTL outputs, it can be further
optimized by disabling TTL outputs with the following command:
35c
35c35c
35c
Note: This command will also disable Wiegand ouputs.
To restore TTL output operations, type:
20c
Note: When the Network Receiver is sending data via the serial port,
the LED labeled DATA TX will alternately flash from red to green.
Observing this LED on the front of the unit will help in verifying proper
operation of a Network Receiver.