Quick Start Owner manual


Command Receiver code Responses
00 Command completed successfully
05 Value entered is out of bounds
06 Invalid or unknown command

A c t io n C o m m and
Set baud rate to 4800 23c
Set baud rate to 9600 24c
Set baud rate to 19200 (default) 25c



 
Action
Command
Turn off Receiver's Wiegand output
29c
Restore Wiegand output (default)
15c
35c
(If your installation does not require them)
Restore TTL output operations
20c
!"
3
34
70
103
13
44
72
105
14
47
75
106
21
52
80
113
22
55
83
114
24
57
93
124
27
58
94
127
33
69
100
#!"$
Action
Command
Delete unwanted ID(s) from Receiver's list
<number>-
Remove all accepted Activator IDs
37c
(Receiver will still pass default ID 127)
Add an Activator ID
<number>+
Reset the list to the valid Activator ID numbers
34c
Code
Reason
04
Trying to delete an ID that has not been programmed
03
Trying to delete all IDs. There must be at least one
02
Trying to enter more than 34 IDs - the maximum
TTL Output 1
TTL Output 2
Action
<number>D
<number>E
Set length of action signal
in seconds. Valid numbers are
000 - 255. Default: 005 seconds
10c
11c
Set output to go from Low to
High
16c
17c
Do not activate TTL output for
a valid Tag read. Default.
30c
31c
Activate TTL output for a valid
Tag read.
13c
14c
Do not activate TTL output
when alarm code received from
a Panic or Tamper Tag. Default.
27c
28c
Activate TTL output when alarm
code received from Panic or
Tamper Tag.
