User`s manual
  Installing under OS/400 
AX3000 - User's Manual  133 
b) Advanced Settings 
Within the Prt5250 box select "Enhanced Parameters" and press <Space>. The 
following dialog box is displayed: 
These parameters are: 
- TCP Port: OS/400 telnet port. Generally 23. 
- TERM Value: terminal capabilities. Default value is IBM-3477-FC. 
- Auto-Connection: if this parameter is set to 'yes', the connection will be 
automatically established when the AX3000 is powered. Otherwise, the 
user can press <Alt><Fx> to establish the connection. 
- Auto-Reconnection: if this parameter is set to 'yes', a new connection is 
automatically established after a disconnection. Otherwise, the user can 
press <Alt><Fx> to establish a new connection. 
- Enhanced Parameters: see Appendix A.10.3. 
- Transparent Mode: this mode allows ASCII data to be sent to printer 
session port. The possible values are: 
- No  
- Yes: data can be encoded in decimal and hexadecimal notations 
- Yes, hexa: data is encoded only in hexadecimal notation. 
- On/Off ASCII Sequence: start and stop transparent mode sequence. For 
more information see Chapter 6.2.5. 
c) Using the Printer 
The Prt5250 service is a client service. This means that each Prt5250 auxiliary 
port opens a connection to the AS/400 when the AX3000 is powered-on. From 
the AS/400, a printer is available once the associated Prt5250 connection is 
established. 