User`s manual
Remote Administration   
214  AX3000 - User's Manual 
'setup_get' command (or 'setup_get_lite' command). This command sends a 
list of all AX3000 parameters to standard output. Example for Unix/Linux: 
# rsh axname setup_get > /tmp/file<CR> 
The message 'Load set-up in progress...' is displayed on the 
operator’s console when the rsh command is processing. If a connection 
problem occurs a time-out error message is displayed. 
When the set-up parameters have been loaded, the message '
OK,  set-up 
sent
' is displayed on the operator’s console. If other messages are displayed, 
refer to chapter 10.3.3. 
The configuration file lists each set-up parameter. Refer to Appendix A.5 for a 
detailed description of this file. 
10.3.3 - Error Messages
There are two types of error: 
- Fatal errors: numbered from 100 to 114, 
- Warning errors: numbered from 200 to 221. 
a) Fatal Errors 
Fatal errors stop the remote command. The following fatal errors may occur: 
ERR 101: header label expected. 
Command:  setup_send 
Cause:  the AXEL header label (BEGIN_AX_SETUP) is not the first 
line of the configuration file. 
Consequence:  the AX3000 set-up is not modified. 
Solution:  check the file. Replace it with a correct configuration file. 
ERR 102: bad header label protocol version. 
Command:  setup_send 
Cause:  the protocol version (included in the header label) cannot be 
processed by the current AX3000 firmware. 
Consequence:  the AX3000 set-up is not modified. 
Solution:  use a configuration file with a compatible protocol. 