User`s manual
Installing under OS/400   
110  TCP/IP AX3000 User's Manual 
Parameters of the RUNRMTCMD command: 
- AX_DOWNLOAD  : command for firmware downloading, 
- password  :  specify the password if the set-up is password-
protected, 
- /axfirm/ax3000  : path and name of the firmware file, 
- 192.168.1.180  : AS/400 IP address, 
- 192.168.1.241  : AX3000 IP address. 
Messages are displayed on the target AX3000 (See Chapter 11.4). 
6.4.6 - Editing AX3000 Statistics
Some AX3000 statistics can be obtained by invoking the following command: 
===> RUNRMTCMD CMD(AX_GETSTAT) RMTLOCNAME('192.168.1.241' *IP) 
Where: 
- AX_GETSTAT  : command for getting statistics, 
- 192.168.1.241  : AX3000 IP address. 
6.5 - FURTHER OPTIONS 
6.5.1 - Turning-Off the AX3000 
A careful check should be made before turning off the TCP/IP AX3000 (an 
operating system cannot detect a TCP/IP device being turned-off). 
To allow graceful terminal shutdown use the <Ctrl><Alt><Del> keystroke 
combination. 
6.5.2 - Reconnection Problem
If an AX3000 5250 session is set with a specific DEVNAME, problems can 
occur if it is not cleanly shutdown before being switched off (see Chapter 6.4.1) 
When a TCP/IP device is switched off (without closing current telnet session), 
the operating system (OS/400) cannot detect this and the OS/400 will refuse 