Interactive Set-Up   
40  TCP/IP AX3000 User's Manual 
To configure the telnet service for the chosen serial auxiliary port, select the 
[Configuration]→[Ports aux.]→[AUXx]  dialog and enter the following 
parameters: 
- Associated Service: select telnet. 
- Net Service Parameters: press <Space> to access the following dialog 
box: 
- Host: name of the host selected from a menu (see Chapter 3.1.2 
or 3.2.3). 
- TCP Port: numeric identifier of the telnet service on the target host. 
The TCP Port default value is 23. 
- TERM Value: the value of this variable is 'negotiated', between the 
host and the AX3000. 
- Auto-Connection: if this parameter is set to 'yes', the connection 
will be automatically established when the AX3000 is powered-up. 
Otherwise, the user can press any key on the serial terminal 
keyboard to establish the connection. 
- Auto-Reconnection: if this parameter is set to 'yes', a new 
connection is automatically established after a disconnection. 
Otherwise, the user can press any key on the serial terminal 
keyboard to establish a new connection. 
Note: the serial auxiliary port used must be configured for 'bi-directional' 
operating mode. 
3.5.5 - Connecting other Peripherals
The tty service provides bi-directional control of the device. 