PHONEX-D1 PHONEX-D2 User Manual 2 Line Digital Telephone Hybrid (Rev. 3.
ENG CONTENT 1 INTRODUCTION ......................................................................................................................................................... 4 1.1 MAIN FEATURES ...................................................................................................................................................... 4 1.2 USE OF THIS MANUAL ......................................................................................................................................
ENG 15.12 CONNECTION TO A NON-BROADCAST MIXING CONSOLE -1 ...................................................................................... 65 15.13 CONNECTION TO A NON-BROADCAST MIXING CONSOLE -2 ...................................................................................... 66 15.14 CONNECTION TO A DIGITAL LINE OR VOIP -1 ......................................................................................................... 67 15.14.1 What is a A.T.A device? .................................
ENG 1 INTRODUCTION PHONEX D1 - PHONE X D2 AVAILABLE VERSION CODE# ARTICLE A112100000 PHONEX D1 A112110000 PHONEX D2 MKII DESCRIPTION Digital studio telephone hybrid 1 line PSTN/POTS. Audio process DSP-Based, XLR analog and AES/EBU input and output.DTMF decoder and GPIN/GPOUT port. Graphic LCD display for TX and RX level monitoring. 1 GSM module for wireless operation (opz).USB and Serial port. 1u rack 19''space. Universal PSU. Digital studio telephone hybrid 2 lines PSTN/POTS.
ENG 1.3 PHONEX D1 AND PHONEX D2 – DEPLIANT AND BROCHURE PhoneX D1 PhoneX D2 BROADCAST SERIES DIGITAL TELEPHONE HYBRIDS HIGHLIGHTS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Digital Telephone hybrid based on DSP audio process Management of 1 or 2 pots/pstn line and GSM QuandBand Audio controls: AGC Stage, Echo canceller, De-Noiser, 2Band Eq, Ducking Hold and Attenuator features on calls Auto-answer and disconnection features Integrated DTMF dialer via software and webpage.
ENG MAIN DESCRIPTION PhoneX D1 and PhoneX D2 are telephone hybrid designed for Broadcast marketplace. The internal frameworks based on DSP (Digital Signal Processor) hit in realtime the highest audio performances, that sets PhoneX D1 and PhoneX D2 as state-of-art technology in telephone interface. As in Macrotel X1 and X2, the PhoneX D1 and D2 equipments allows to manage one or two landlines, shared with GSM QuadBand modem optionally improved, to place phone calls where wired lines are not available.
ENG TECH SPECS PhoneX D1 – PhoneX D2 General Features End User / Price List Lines Phone Line Set Line GSM Line Line Mode Telephone Set mode PhoneX D1 1.290 € 1 Pots/Pstn Line or 1 GSM Line (by option) 1x RJ11 6/4 1x RJ11 6/4 1x RJ10 PhoneX D2 1.700 € 2 Pots lines or 2 GSM lines (by option) or 1 Pots line + 1 GSM line (by option) 2x RJ11 6/4 2x RJ11 6/4 2x RJ10 Standard 2-Wire connection or GSM(by option) Worldwide, software setup Audio Features Audio process A.G.
ENG COMPARISON TABLE General Features Macrotel X1 Macrotel X2 PhoneX D1 PhoneX D2 End User / Price List Telephone Lines Configuration 1 Pots/Pstn line or 1 GSM line 2 Pots/Pstn lines or 2 GSM Lines or 1 Pots line + 1 GSM line 1 Pots/Pstn line or 1 GSM line 2 Pots/Pstn lines or 2 GSM Lines or 1 Pots line + 1 GSM line GSM Quad Band Module Line Mode Telephone Set mode 1x optional 2x optional 1x optional 2x optional Standard 2-Wire RJ11 6/4 connection or GSM (by option) Worldwide mode, software setu
ENG 1 SAFETY WARNINGS / ISTRUZIONI PER LA SICUREZZA SAFETY WARNINGS CONSIGNES DE SÉCURITÉ IMPORTANTES ISTRUZIONI IMPORTANTI PER LA SICUREZZA WICHTIGE SICHERHEITSHINWEISE INSTRUCCIONES IMPORTANTES DE SEGURIDAD (Rel. 2.0) 1.1 FOREWORD For your own safety and to avoid invalidation of the warranty all text marked with these Warning Symbols should be read carefully. Information in this manual is subject to change without notice and does not represent a commitment on the part of the vendor.
ENG 2 SAFETY WARNINGS The installation and servicing instructions in this manual are for use by qualified personnel only. - Read All Instructions. All safety and operating instructions must be read before operating the product. They also must be retained for future reference, as it contains a number of useful hints for determining the best combination of equipment settings for Yr particular application. - Heed All Warnings.
ENG 3 CONSIGNES DE SÉCURITÉ IMPORTANTES - Lire ces consignes - Conserver ces consignes - Observer tous les avertissements - Suivre toutes les consignes - Ne pas utiliser cet appareil à proximité de l’eau - Ne pas obstruer les ouvertures de ventilation. Installer en respectant les consignes du fabricant - Ne pas installer à proximité d'une source de chaleur telle qu'un radiateur, une bouche de chaleur, un poêle ou d'autres appareils (dont les amplificateurs) produisant de la chaleur.
ENG 4 ISTRUZIONI IMPORTANTI PER LA SICUREZZA - Leggere le presenti istruzioni - Conservare queste istruzioni - Osservare tutte le avvertenze - Seguire scrupolosamente tutte le istruzioni - Non usare questo apparecchio in prossimità di acqua - Non ostruire alcuna apertura per il raffreddamento.
ENG 5 WICHTIGE SICHERHEITSHINWEISE - Diese Hinweise LESEN - Diese Hinweise AUFHEBEN - Alle Warnhinweise BEACHTEN - Alle Anweisungen BEFOLGEN - Dieses Gerät NICHT in der Nähe von Wasser verwenden - KEINE Lüftungsöffnungen verdecken. Gemäß den Anweisungen des Herstellers einbauen - Nicht in der Nähe von Wärmequellen, wie Heizkörpern, Raumheizungen, Herden oder anderen Geräten (einschließlich Verstärkern) installieren, die Wärme erzeugen - Die Schutzfunktion des Schukosteckers NICHT umgehen.
ENG Inpoliger Netzschalter. In Notfälle oder für Wartungsarbeiten Netzkabel trennen.
ENG 6 INSTRUCCIONES IMPORTANTES DE SEGURIDAD - LEA estas instrucciones - CONSERVE estas instrucciones - PRESTE ATENCION a todas las advertencias. - SIGA todas las instrucciones - NO utilice este aparato cerca del agua - NO obstruya ninguna de las aberturas de ventilación.
ENG El interruptor de alimentación es unipolar. En el caso de peligro, desconecte el cable de alimentación.
UNPACKING AND INSPECTION 7 UNPACKING AND INSPECTION Your equipment was packed carefully at the factory in a container designed to protect the unit during shipment. Nevertheless, we recommend making a careful inspection of the shipping carton and the contents for any signs of physical damage. Damage & Claims If damage is evident, do not discard the container or packing material. Contact your carrier immediately to file a claim for damages.
FIRST INSTALLATION RECOMMENDATIONS 8 FIRST INSTALLATION RECOMMENDATIONS 8.1 POWER SUPPLY CABLE A power supply cable of approx. 2 mt length is supplied with the device, which has a moulded IEC plug attached – this is a legal requirement. The type of plug for the power supply depends on the country in which it is delivered.
FIRST INSTALLATION RECOMMENDATIONS 8.3 FUSE REPLACEMENT The power supply socket has an integral fuse drawer containing the AC power fuse and a spare, both of the same value. BEFORE REPLACING THE POWER FUSE, MAKE SURE YOU HAVE THE RIGHT TYPE OF FUSE FOR THE VOLTAGE TO BE PROTECTED. USING WRONG FUSE TYPE WILL RESULT IN INSUFFICIENT PROTECTION. Make sure that the power is switched off and the power cable is disconnected from the equipment. a. Open the upper iron cover using a screwdriver. b.
FIRST INSTALLATION RECOMMENDATIONS Perform the set-up under static control conditions. Static charges are likely to completely destroy one or more of the CMOS semiconductors employed in the unit. Static damage will not be covered under warranty. Basic damage prevention consists of minimizing generation, discharging any accumulated static charge on your body and preventing that discharge from being sent to or through any electronic component.
FIRST INSTALLATION RECOMMENDATIONS 8.5 VENTILATION The equipment will operate as a free-standing unit without requiring any special cooling arrangement. However, slots and openings in the product are provided for ventilation. They ensure reliable operation of the product, keeping it from overheating. These openings must not be blocked nor covered during operation. YOU MUST LEAVE AT A MINIMUM ONE RACK UNIT OF EMPTY SPACE ABOVE THE EQUIPMENT TO ENHANCE VENTILATION AND TO GET A LONGER EQUIPMENT LIFE.
PHONEX D1 AND PHONEX D2 GENERAL DESCRIPTION 9 PHONEX D1 AND PHONEX D2 GENERAL DESCRIPTION 9.1 N° PHONEX D1 FRONT PANEL NOME CONTROLLO FUNZIONE 1 DISPLAY LCD LCD Display that shows the status and operating mode of PhoneXD1. The technical parameters of each menu are displayed here 2 JOG-SHUTTLE Knob (or JogShuttle) to access the various navigation menus and make changes. Press the JogShuttle to confirm selection.
PHONEX D1 AND PHONEX D2 GENERAL DESCRIPTION 9.2 PHONEX D1 REAR PANEL N° NOME CONTROLLO FUNZIONE 1 DIGITAL I/O Digital AES3/EBU audio input on balanced XLR connector with 110Ω impedance. Digital AES3/EBU audio output on balanced XLR connector with 110Ω impedance. Connector 2D is disabled on PhoneX D1 2 “USB” PORT PhoneX D1 allows to be connected to PC via USB port.
PHONEX D1 AND PHONEX D2 GENERAL DESCRIPTION - GPI Status - GPO Status As regards the Opto Interface port pinout see the Appendix at the end of this manual. For the operation of each GPI and GPO see the specific section in the next pages of this manual. 5 ANALOG OUTPUT Electronically balanced analog audio output of the second hybrid, on Balanced XLR connector, Mono type. The two connectors presents the same-same signal in outputs.
PHONEX D1 AND PHONEX D2 GENERAL DESCRIPTION 9.3 N° PHONEX D2 FRONT PANEL NOME CONTROLLO FUNZIONE 1 DISPLAY LCD LCD Display that shows the status and operating mode of PhoneXD1. The technical parameters of each menu are displayed here 2 JOG-SHUTTLE Knob (or JogShuttle) to access the various navigation menus and make changes. Press the JogShuttle to confirm selection. 3 “ESC” BUTTON Press this key to delete the changes made or exit the selected menu 4 “HOOK-1” BUTTON Line hook/unhook key.
PHONEX D1 AND PHONEX D2 GENERAL DESCRIPTION 9.4 PHONEX D2 REAR PANEL N° 1 FUNZIONE NOME CONTROLLO DIGITAL I/O Digital AES3/EBU audio input on balanced XLR connector with 110Ω impedance. Digital AES3/EBU audio output on balanced XLR connector with 110Ω impedance, in PhoneX D2 the inputs are divided as following: 1C – Hybrid 1 Input 2D – Hybrid 2 Input 2 “USB” PORT + 3 PhoneX D2 allows to be connected to PC via USB port.
PHONEX D1 AND PHONEX D2 GENERAL DESCRIPTION 4 “GPIO” PORT Interface with 15 pin female HD SubD connector. Determines the PhoneX D2 logic status via the GPOut open collector, while it provides the PhoneX D2 command via GPIn, thanks to the opto couplers installed. The PhoneX D2 status is also visible from the software panel on the right section of the software: - GPI Status - GPO Status As regards the Opto Interface port pinout see the Appendix at the end of this manual.
INSTALLATION AND USE OF THE CONTROL SOFTWARE 10 INSTALLATION AND USE OF THE CONTROL SOFTWARE The installation procedure of the PhoneX D1 and PhoneX D2 control software is described below. The program runs on all Windows platforms, including Windows Xp sp3, Windows Vista and Windows 7 32-bit and Windows 7 64-bit and Windows 8 Pro 64bit. The control software must be installed before connecting the devices to the USB port.
INSTALLATION AND USE OF THE CONTROL SOFTWARE 5. Select a destination folder or leave folder unchanged, click NEXT and then INSTALL 6. The software will start the installation of the program on the PC; when complete the following page will be displayed 7. Click FINISH to end the installations; two new icons with the Falcon Three SDI TV picture will appear on the desktop and in the program list. The two icons refer to the programs: a. b. 8. Axel Telephone Hybrid Remoter v2.0.
USE OF THE PHONEX ADDRESS MANAGER SOFTWARE 11 USE OF THE PHONEX ADDRESS MANAGER SOFTWARE The PhoneX Address Manager software assigns a TCP/IP address, the relevant Subnet Mask, a Gateway and a port to PhoneX. This is obtained using the PC’s serial port on which PhoneX Address Manager is installed and the SERIAL-1 port of the PhoneX device.
USE OF TELEPHONE HYBRID REMOTER 12 USE OF TELEPHONE HYBRID REMOTER Start window of the PhoneX control software 12.1 ACCESS VIA SERIAL CONNECTION To operate on the PhoneX, after having allocated the serial port and TCP/IP values it is necessary to use the PhoneX Remoter program by clicking the special icon. The window below shows the PhoneX and PC connection via Rs232 serial port. As can be seen, a USB connection is being used on the COM5 port of the PC in use.
USE OF TELEPHONE HYBRID REMOTER 12.2 ACCESS VIA TCP/IP CONNECTION To access and manage the device via TCP/IP follow the simple instructions below. Unlike a serial connection, a TCP/IP connection is extremely useful when more than one unit must be managed. In this way it is possible to connect to PhoneX devices and manage each one in remote mode from one single point. 1. Click “Remote Connection” 2. Click “EDIT” 3.
MANAGE PHONEX D1 AND PHONEX D2 VIA SOFTWARE 13 MANAGE PHONEX D1 AND PHONEX D2 VIA SOFTWARE Axel Telephone Hybrid Remoter is a program to manage and control PhoneX both locally (via serial connection) and remotely via TCP/IP connection. As regards the monitoring functions, the front panel also shows the Send and Receive levels and primary functions such as line hook, ducking, attenuation and hold.
MANAGE PHONEX D1 AND PHONEX D2 VIA SOFTWARE A Web Server is also available inside the device to display data via Web browser, such as Mozilla, Internet Explorer or Google Chrome.
TELEPHONE HYBRID REMOTER DETAIL 14 TELEPHONE HYBRID REMOTER DETAIL 14.1 PHONEX D1 CONTROL SOFTWARE DESCRIPTION The PhoneX D1 control software (Telephone Hybrid Remoter) is basically divided into 4 parts: 1. 2. 3. 4. Hybrid 1 section Levels section GPI / GPO status section Setup & Disconnect section 14.2 HYBRID 1 SECTION The “Hybrid 1 Section” features a series of operating and monitoring controls relating to the first telephone hybrid connected to a PSTN/POTS line.
TELEPHONE HYBRID REMOTER DETAIL ATTEN: when ATTEN is pressed via software or via GPIn connection, a dB reduction equal to the Ducking value set in the control software is applied to the Receive signal: HOLD: when HOLD is pressed via software the Receive volume is taken to –infinity without closing the call. DIAL: when DIAL is pressed the DTMF dialler opens. Dial the number using the numerical keyboard of your PC and then click ON HOOK.
TELEPHONE HYBRID REMOTER DETAIL 14.4 GPIO STATUS SECTION The GPI / GPO Status section shows the status of the General Purpose Input and Output status. The 25 pin female SubD port on the back of the device is used to connect the device; see the technical appendix for the connections and the pinout. 14.4.
TELEPHONE HYBRID REMOTER DETAIL 14.5.1 Hybrid 1 section In this section all the parameters relating to the Telephone Hybrid 1 (Hybrid 1) can be set INPUT SOURCE: This is the input of the Hybrid 1, i.e. what is sent (SEND) to the telephone interlocutor. The options available are: Analog, Digital Left, Digital Right and Microphone. The sensitivity levels of each input are shown at the side and are identified as follows. ANALOG SENSITIVITY: this is the sensitivity of the balanced analog input.
TELEPHONE HYBRID REMOTER DETAIL Echo Tail: this is the value in ms of the Echo that is eliminated by the PhoneX DSP. It is used together with the Echo Cancelling command that controls the cancellation speed of the Echo on the telephone line. This parameter acts on an automatic variation filter to cancel the echo. The operating parameters self-adapt to the status of the line, of the input and output levels.
TELEPHONE HYBRID REMOTER DETAIL Ducking & Attenuation: In this section the attenuation values can be adjusted from 1dB to 30dB. This section includes the ducking function (with On/Off action), which attenuates the input signal from the line of the value set in the Attenuation parameter, when the input level to the line is higher than the threshold set. Attenuation can be enabled or the interlocutor can be placed on “HOLD”, which takes attenuation to -∞.
TELEPHONE HYBRID REMOTER DETAIL DIGITAL OUTPUT Nominal Output Level: This parameter changes the nominal level of the AES/EBU output. Range of allowed values: from -24.0 dBFs to a maximum of -5.0 dBFs. This parameter can be used to change the digital output of Hybrid 1 and Hybrid 2. Frequency: output frequency of the AES/EBU digital signal. Values allowed: 32kHz, 44.1kHz, 48kHz, 64kHz, 88.2kHz, 96kHz. Resolution: parameter used to set the resolution of the AES/EBU output digital signal.
TELEPHONE HYBRID REMOTER DETAIL 14.5.3 Program Settings Section The Program Settings section shows all the functions of the PhoneX Remoter Control Software and of the PhoneX D1 device. Visualisation and Program Features: The “Show peak meter” checkbox offers the possibility to see the peak meter on the levels section of the two Hybrids. Setup Password: This field is used to enter an alphanumeric Password of maximum 8 digits, which is required to access the device Setup section.
TELEPHONE HYBRID REMOTER DETAIL Serial2 Setup: this setup allows the PhoneX D1 to use the Serial -2 as a common Serial port or a port where the GSM module can be connected. In any case ASCII parser data can be sent to the PhoneX D1. UNDO: press UNDO to reset the values set in the whole Hybrid 1 and Outputs section to the values set on the device before the opening of the control panel. The Disconnect key disconnects the device from the control software.
TELEPHONE HYBRID REMOTER DETAIL 14.6 PHONEX CONTROL SOFTWARE DESCRIPTION Phonex control software description The PhoneX control software (PhoneX Remoter) is basically divided into 5 parts: 5. 6. 7. 8. 9. Hybrid 1 section Hybrid 2 section Levels section GPI / GPO status section Setup & Disconnect section 14.7 HYBRID 1 SECTION The “Hybrid 1 Section” features a series of operating and monitoring controls relating to the first telephone hybrid connected to a PSTN/POTS line.
TELEPHONE HYBRID REMOTER DETAIL DIAL: when DIAL is pressed the DTMF dialler opens. Dial the number using the numerical keyboard of your PC and then click ON HOOK. In this way the DTMF dials the number to be called on the telephone line. The Latest 10 Calls section displays the last ten calls; click SAVE to permanently save a telephone number. To recall a number double click on it.
TELEPHONE HYBRID REMOTER DETAIL 14.10.1 GPI status function HOOK 1: this is used to hook, by means of a stable contact, the telephone line of Hybrid 1; it is usually connected to the TELCO (N-1) modules of the Broadcast Mixing consoles that feature a GPO contact to answer incoming calls directly from the telephone fader.
TELEPHONE HYBRID REMOTER DETAIL INPUT SOURCE: This is the input of the Hybrid 1, i.e. what is sent (SEND) to the telephone interlocutor. The options available are: Analog, Digital Left, Digital Right and Microphone. The sensitivity levels of each input are shown at the side and are identified as follows. ANALOG SENSITIVITY: this is the sensitivity of the balanced analog input. Range of allowed values: from -12.0 dBu to a maximum of +12.0 dBu in 0.1 dBu steps.
TELEPHONE HYBRID REMOTER DETAIL Echo Tail: this is the value in ms of the Echo that is eliminated by the PhoneX DSP. It is used together with the Echo Cancelling command that controls the cancellation speed of the Echo on the telephone line. This parameter acts on an automatic variation filter to cancel the echo. The operating parameters self-adapt to the status of the line, of the input and output levels.
TELEPHONE HYBRID REMOTER DETAIL Ducking & Attenuation: In this section the attenuation values can be adjusted from 1dB to 30dB. This section includes the ducking function (with On/Off action), which attenuates the input signal from the line of the value set in the Attenuation parameter, when the input level to the line is higher than the threshold set. Attenuation can be enabled or the interlocutor can be placed on “HOLD”, which takes attenuation to -∞.
TELEPHONE HYBRID REMOTER DETAIL 14.11.2 Hybrid 2 section In this section all the parameters relating to the Telephone Hybrid 2 (Hybrid 2) can be set INPUT SOURCE: This is the input of the Hybrid 2, i.e. what is sent (SEND) to the telephone interlocutor. The options available are: Analog, Digital Left, Digital Right and Microphone. The sensitivity levels of each input are shown at the side and are identified as follows. ANALOG SENSITIVITY: this is the sensitivity of the balanced analog input.
TELEPHONE HYBRID REMOTER DETAIL Echo Tail: this is the value in ms of the Echo that is eliminated by the PhoneX DSP. It is used together with the Echo Cancelling command that controls the cancellation speed of the Echo on the telephone line. This parameter acts on an automatic variation filter to cancel the echo. The operating parameters self-adapt to the status of the line, of the input and output levels.
TELEPHONE HYBRID REMOTER DETAIL Ducking & Attenuation: In this section the attenuation values can be adjusted from 1dB a 30dB. This section includes the ducking function (with On/Off action), which attenuates the input signal from the line of the value set in the Attenuation parameter, when the input level to the line is higher than the threshold set. Attenuation can be enabled or the interlocutor can be placed on “HOLD”, which takes attenuation to-∞.
TELEPHONE HYBRID REMOTER DETAIL 14.11.3 Outputs Section This section includes the parameters to change the output operating mode. It is divided into two sections: Digital Output and Analog Output DIGITAL OUTPUT Nominal Output Level: This parameter changes the nominal level of the AES/EBU output. Range of allowed values: from -24.0 dBFs to a maximum of -5.0 dBFs. This parameter can be used to change the digital output of Hybrid 1 and Hybrid 2. Frequency: output frequency of the AES/EBU digital signal.
TELEPHONE HYBRID REMOTER DETAIL 14.11.4 Program Settings Section The Program Settings section shows all the functions of the PhoneX Remoter Control Software and of the PhoneX device. Visualisation and Program Features: The “Show peak meter” checkbox offers the possibility to see the peak meter on the levels section of the two Hybrids. Setup Password: This field is used to enter an alphanumeric Password of maximum 8 digits, which is required to access the device Setup section.
PHONEX CONNECTIONS 15 PHONEX CONNECTIONS 15.1 TELEPHONE HYBRID CONCEPT The hybrid phone is a device capable of interfacing with a telephone line of audio lines. In practice, the audio signals sent toward the hybrid are received from the phone, and vice versa. The telephone hybrid is widely used in radio and television, as it allows you to create simple audio connections with remote locations in a very low cost. The signal coming from the telephone hybrid is run like a normal audio source.
PHONEX CONNECTIONS 15.3 CONNECTION TO THE POTS / PSTN TELEPHONE LINE CHECK that this device is connected to POTS / PSTN lines (analog) DO NOT CONNECT this device to digital telephone lines DO NOT CONNECT this device to ADSL lines, even if fitted with filter. To avoid any type of hum at 50 Hz and to comply with EMC requirements, the device must be connected to earth by means of the earthing screw on the rear panel or via the power supply cable.
PHONEX CONNECTIONS If the unit has operating problems caused by lightening or over voltage, disconnect it immediately from the telephone line and electric power supply; do not reconnect it until the device has been duly checked. If in doubt contact the technical assistance service. Make sure also that your system is fitted with adequate lightening protection. If this is not the case, we recommend disconnecting all connectors during thunderstorms or if the device is not used for long periods of time.
PHONEX CONNECTIONS 15.4 GSM MODULE 1 AND GSM MODULE 2 WIRELESS CONNECTION Up to two GSM devices can be connected to PhoneX with mutual exchange between the POTS line and the GSM line. See the LINE TYPE section for the mute exchange of this line. The image below shows how to connect the GSM-1 AND GSM-2 modules. They can also be connected at the same time. The cable A-1 (Cable A-1) it’s a audio cable,with a RJ10 side directly connected to the “GSM” port LINE 1 in PhoneX D1.
PHONEX CONNECTIONS 15.5 GSM MODULE 1 AND 2 POTS LINES CONNECTION Is it possible to connects to a PhoneX D2 one single GSM module and 2 POTS Lines. In any case, via software some configurations must be done.
PHONEX CONNECTIONS 15.6 AUDIO CONNECTION TO AND FROM PHONEX D1 AND PHONEX D2 The PhoneX can be connected to other devices such as Mixers or digital consoles in different ways. PhoneX features two possible types of connections, the Single Mode or the Conference Mode. Both are detailed below. The following connections are available in Single Mode: a. b. c. d. Analog connection in Single Mode with one telephone line. (PhoneX D1) Analog connection in Single Mode with two telephone lines.
PHONEX CONNECTIONS 15.8 ANALOG CONNECTION IN SINGLE MODE WITH TWO TELEPHONE LINES (PHONEX D2) In this mode the PhoneX device is connected to the console using an analog audio line. An audio signal from the Telco output of the mixer (N-1) for the first and second telephone lines is sent to the Send Hybrid 1 and Send Hybrid 2 of PhoneX. The output is sent via Receive Hybrid 1 and Receive Hybrid 2 to the Telco module relating to Hybrid 1 and Hybrid 2 on the mixer.
PHONEX CONNECTIONS 15.9 DIGITAL CONNECTION IN SINGLE MODE WITH ONE TELEPHONE LINE (PHONEX D1) In this mode the PhoneX device is connected to the console using a digital audio line. An audio signal from the Telco output of the mixer (N-1) for the first telephone line is sent to the Send Hybrid 1 of PhoneX. The conncetion must be done between the Telco Module and input 1C. The output is sent via Receive Hybrid 1 to the Telco module relating to Hybrid 1 on the mixer.
PHONEX CONNECTIONS 15.10 DIGITAL CONNECTION IN SINGLE MODE WITH TWO TELEPHONE LINES (PHONEX D2) In this mode the PhoneX device is connected to the console using a digital audio line. An audio signal from the Telco output of the mixer (N-1) for the first and second telephone lines is sent to the Send Digital of PhoneX. The output is sent via Receive Digital to the Telco module relating to the Telephone Hybrid.
PHONEX CONNECTIONS 15.11 ANALOG CONNECTION, IN CONFERENCE MODE, WITH TWO TELEPHONE LINES AND THREE PHONEX. This mode exploits the maximum modularity of the PhoneX device. All the hybrids are connected to each other in “cascade” and all the PhoneX devices can be controlled from the console simply using one single Telcon N-1 channel. The Conference mode on the Analog Output of each hybrid must be enabled to operate in this mode.
PHONEX CONNECTIONS 15.12 CONNECTION TO A NON-BROADCAST MIXING CONSOLE -1 This way of connecting the Macrotel or Phonex telephone hybrid, allows the user to connect a “not broadcast” mixing console. In the example above this console not having all the functionality of a console "Broadcast" feature offers a service to connect directly to the telephone hybrid mixer.
PHONEX CONNECTIONS 15.13 CONNECTION TO A NON-BROADCAST MIXING CONSOLE -2 This way of connecting the Macrotel or Phonex, allows users to connect a mixing console that is not “broadcast”. In the example above it is possible to understand that the console in use is completely devoid of the functionality of TELCO, Mix-Minus or N-1. At this point the service of Telco must be created, and executed with what it has available, namely the AUX bus.
PHONEX CONNECTIONS 15.14 CONNECTION TO A DIGITAL LINE OR VOIP -1 It is not technically possible to directly connect a VoIP hybrid phone directly. You must insert between VoIP and Telephone Hybrid a A.T.A device 15.14.1 What is a A.T.
PHONEX CONNECTIONS 15.15 CONNECTION TO A DIGITAL LINE OR VOIP -2 In the event you need to connect a digital line to a hybrid phone, you must enter an ATA which means Analog telephone adapter, or an adapter between a digital line PSTN analog. Each manufacturer has its general, although some still exist generics on the market. Contact your phone service provider for the installation of the same. In the above example an adapter to ONE SINGLE LINE.
PHONEX CONNECTIONS 15.16 CONNECTION TO A DIGITAL LINE OR VOIP -3 In the event you need to connect a digital line to a hybrid phone, you must enter an ATA which means Analog telephone adapter, or an adapter between a digital line PSTN analog. Each manufacturer has its general, although some still exist generics on the market. Contact your phone service provider for the installation of the same. In the above example an adapter for multiple output lines.
TECHNICAL APPENDIX 16 TECHNICAL APPENDIX This section provides all the technical explanations, and the connection pinouts to and from the PhoneX device. Always refer to this technical appendix for connections and connection procedures. In case of differences between the documentation below and the hardware device please contact Axel Technology at the numbers and e-mail addresses shown at the end of this manual. Our technical and assistance department will be pleased to help you! 16.
TECHNICAL APPENDIX 16.3 APPENDIX C – ETHERNET / LAN CONNECTION 16.
TECHNICAL APPENDIX 16.5 APPENDIX E – GPIO PORT The SubD connector 15pole HD GPIO place on the rear of PhoneX, provides 4 inputs General Purpose and 4 outputs General Purpose binary. The inputs are polarized on Opto coupler while the outputs are open collector. They can be used to send commands at the equipment and perform certain functions. The inputs are constituted by photocouplers polarized on each input and is always inserted, inside, a protection resistor 150 ohms in series.
TECHNICAL APPENDIX 16.5.2 Connection to GPIn and GPOut via external activation (TTL) As shown in the diagram below, taking the voltage externally apparatus it is possible to polarize a photo coupler and implement one of the 4 GP Input available. Note: in this case the masses of the TTL signals generators are common.
TECHNICAL APPENDIX 16.5.3 Connection to GPIn and GPOut via external activation -2 (TTL) As shown in the diagram below, taking the voltage externally apparatus it is possible to polarize a photo coupler and implement one of the 4 GP Input available. Note: in this case the masses of the TTL signals generators are common.
TECHNICAL APPENDIX 16.5.
TECHNICAL APPENDIX For the function of each GPO see the Program Settings section, from where various functions can be assigned to the GPOs. For the purpose of each single GPO please refer to the Program Settings section in the Telephone Hybrid Remoter.
TECHNICAL APPENDIX 16.5.5 DTMF Remote commands Into the Program Settings section it is possible to find a special section designed for GPO and DTMF Decoder If the Checkbox DTMF Decoder is selected, PhoneX introduce a control and a DTMF decoder over the line numer ONE, into PhoneX D1 and over the line number ONE also in PhoneX D2 in the Receive side. In case a DTMF is recognized, an action is taken by the PhoneX, as a GPO closure.
APPENDIX F – PHONEX FIRMWARE UPDATE 17 APPENDIX F – PHONEX FIRMWARE UPDATE The most recent firmware version is installed by the manufacturer on PhoneX before it is delivered. Once purchase, the firmware can be updated with the latest version available. The Firmware Upgrade can be carried using the Windows operating system. The suitable operating systems are: Windows Xp Sp3, Windows Vista and Windows 7 Ultimate 32 Bit and 64bit. Check that Microsoft .
APPENDIX F – PHONEX FIRMWARE UPDATE f. g. h. i. Select the PC serial port on the screen Shut Down the PhoneX D1 o PhoneX D2 Starts PhoneX D1 or PhoneX D2 within 3 seconds and press the CONNECT button Once the software is correctly connected to the PhoneX D1 and PhoneX D2 a screen like the following one is showned, and at the same time the front PhoneX display show no things and stay completely empty. j. Once the PhoneX is connected press PROGRAM k.
TECHNICAL SPECIFICATION PHONEX D1 – PHONEX D2 18 TECHNICAL SPECIFICATION PHONEX D1 – PHONEX D2 GENERAL Dimension AC Rate Type of power supply Processing architecture Weight Operating Temperature Compliance ANALOG INPUT MODULE (send) A/D Conversion Connectors: AD Clipping Point Operative Nominal Level: Line Impedance Distortion: AD Dynamic Range: Input Modes: Microphone Impedance Microphone gain DIGITAL INPUT MODULE (send) Connectors: Format Sample rates Operative Nominal level: Dynamic Range: Distortion In
WEEE Directive – Informativa RAEE 19 WEEE Directive – Informativa RAEE In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE), this electrical product must not be disposed of as unsorted municipal waste. Please dispose of this product by returning it to the point of sale or to your local municipal collection point for recycling.
WARRANTY 20 WARRANTY Il produttore offre un anno di garanzia Franco Fabbrica. Non aprire l’apparato. L’eventuale rottura dei sigilli di garanzia determina la decadenza della stessa. Il produttore non risponde per danni di alcun genere derivanti, o in relazione, all’uso errato del prodotto.
FINAL NOTE AND AXELTECHNOLGY IN TOUCH 22 FINAL NOTE AND AXELTECHNOLGY IN TOUCH ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ____________________________________________