MACROTEL X1 MACROTEL X2 User Manual 1 or 2 Telephone Line Digital Telephone Hybrid (Rev. 3.
ENG 1 CONTENTS 1 INTRODUCTION ......................................................................................................................................................... 4 1.1 MAIN FEATURES ............................................................................................................................................... 4 1.2 USE OF THIS MANUAL.......................................................................................................................................
ENG 17.1 APPENDIX A – BALANCED AUDIO CONNECTION AND PINOUT ................................................................... 57 17.2 APPENDIX B – SERIAL CONNECTION E PINOUT........................................................................................... 57 17.3 APPENDIX C – USB A/B CONNECTION........................................................................................................... 58 17.4 APPENDIX D – GPIO PORT ....................................................................
ENG 1 INTRODUCTION MACROTEL X1 AND MACROTEL X2 – AVAILABLE VERSIONS CODE# ARTICLE A112080000 MACROTEL X1 A112090000 MACROTEL X2 DESCRIPTION Digital telephone hybrid, 1 PSTN/POTS line. DSP audio processing, input and XLR analog output. RX/TX level displayed on LCD display. Possibility of adding 1 optional GSM module. USB and Serial port. GPIN and GPOUT for Telco modules. 19'' 1u Rack. Incorporated universal power supply. Digital telephone hybrid, 2 PSTN/POTS lines.
ENG MACROTEL X1 – MACROTEL X2 – DEPLIANT AND BROCHURE 1.3 Macrotel X1 Macrotel X2 HIGHLIGHTS Digital Telephone hybrid based on DSP audio process 1 or 2 land/wireless lines managed via pots or GSM QuandBand Audio controls: AGC Stage, Attenuator, Echo canceller, 2Band Eq Integrated DTMF dialer via software with auto-answer and disconnection Separate send and receive over balanced XLR with Mic/Line software selection 2 Rs232 serial ports, 1 USB B-type, Gpio for Telco N-1 mixing console.
ENG MAIN DESCRIPTION Macrotel X1 and Macrotel X2 are the Axel Technology’s Telephone hybrid third generation for a supreme audio quality. Macrotel X1manages one line pots/pstnwhile Macrotel X2 can operate on two lines pots/pstn. Moreover, in every landline it’s available a switching “land to wireless mode” through one or two optional QuadBand GSM module to establish telephone connection where wired lines are not arranged.
ENG TECH SPECS MACROTEL X1 - MACROTEL X2 Macrotel X1 799 € General Features End User / Price List Lines 1 Pots/Pstn Line or 1 Gsm Line (by option) Phone Line Set Line GSM Line Line Mode Telephone Set mode 1x RJ11 6/4 1x RJ11 6/4 1x RJ10 Macrotel X2 1.085 € 2 Pots lines or 2 GSM lines(by option) or 1 Pots line + 1 GSM line (by option) 2x RJ11 6/4 2x RJ11 6/4 2x RJ10 Standard 2-Wire connection or GSM(by option) Worldwide mode, software setup Audio Features Audio process A.G.
ENG 1 SAFETY WARNINGS / ISTRUZIONI PER LA SICUREZZA SAFETY WARNINGS CONSIGNES DE SÉCURITÉ IMPORTANTES ISTRUZIONI IMPORTANTI PER LA SICUREZZA WICHTIGE SICHERHEITSHINWEISE INSTRUCCIONES IMPORTANTES DE SEGURIDAD (Rel. 2.0) 1.1 FOREWORD For your own safety and to avoid invalidation of the warranty all text marked with these Warning Symbols should be read carefully. Information in this manual is subject to change without notice and does not represent a commitment on the part of the vendor.
ENG 2 SAFETY WARNINGS The installation and servicing instructions in this manual are for use by qualified personnel only. - Read All Instructions. All safety and operating instructions must be read before operating the product. They also must be retained for future reference, as it contains a number of useful hints for determining the best combination of equipment settings for Yr particular application. - Heed All Warnings.
ENG 3 CONSIGNES DE SÉCURITÉ IMPORTANTES - Lire ces consignes - Conserver ces consignes - Observer tous les avertissements - Suivre toutes les consignes - Ne pas utiliser cet appareil à proximité de l’eau - Ne pas obstruer les ouvertures de ventilation. Installer en respectant les consignes du fabricant - Ne pas installer à proximité d'une source de chaleur telle qu'un radiateur, une bouche de chaleur, un poêle ou d'autres appareils (dont les amplificateurs) produisant de la chaleur.
ENG 4 ISTRUZIONI IMPORTANTI PER LA SICUREZZA - Leggere le presenti istruzioni - Conservare queste istruzioni - Osservare tutte le avvertenze - Seguire scrupolosamente tutte le istruzioni - Non usare questo apparecchio in prossimità di acqua - Non ostruire alcuna apertura per il raffreddamento.
ENG 5 WICHTIGE SICHERHEITSHINWEISE - Diese Hinweise LESEN - Diese Hinweise AUFHEBEN - Alle Warnhinweise BEACHTEN - Alle Anweisungen BEFOLGEN - Dieses Gerät NICHT in der Nähe von Wasser verwenden - KEINE Lüftungsöffnungen verdecken. Gemäß den Anweisungen des Herstellers einbauen - Nicht in der Nähe von Wärmequellen, wie Heizkörpern, Raumheizungen, Herden oder anderen Geräten (einschließlich Verstärkern) installieren, die Wärme erzeugen - Die Schutzfunktion des Schukosteckers NICHT umgehen.
ENG Inpoliger Netzschalter. In Notfälle oder für Wartungsarbeiten Netzkabel trennen.
ENG 6 INSTRUCCIONES IMPORTANTES DE SEGURIDAD - LEA estas instrucciones - CONSERVE estas instrucciones - PRESTE ATENCION a todas las advertencias. - SIGA todas las instrucciones - NO utilice este aparato cerca del agua - NO obstruya ninguna de las aberturas de ventilación.
ENG El interruptor de alimentación es unipolar. En el caso de peligro, desconecte el cable de alimentación.
UNPACKING AND INSPECTION 7 UNPACKING AND INSPECTION Your equipment was packed carefully at the factory in a container designed to protect the unit during shipment. Nevertheless, we recommend making a careful inspection of the shipping carton and the contents for any signs of physical damage. Damage & Claims If damage is evident, do not discard the container or packing material. Contact your carrier immediately to file a claim for damages.
FIRST INSTALLATION RECOMMENDATIONS 8 FIRST INSTALLATION RECOMMENDATIONS 8.1 POWER SUPPLY CABLE A power supply cable of approx. 2 mt length is supplied with the device, which has a moulded IEC plug attached – this is a legal requirement. The type of plug for the power supply depends on the country in which it is delivered.
FIRST INSTALLATION RECOMMENDATIONS BEFORE REPLACING THE POWER FUSE, MAKE SURE YOU HAVE THE RIGHT TYPE OF FUSE FOR THE VOLTAGE TO BE PROTECTED. USING WRONG FUSE TYPE WILL RESULT IN INSUFFICIENT PROTECTION. Make sure that the power is switched off and the power cable is disconnected from the equipment. a. Open the upper iron cover using a screwdriver. b. Replace the fuse located at the internal position – Power supply Type-1 c.
FIRST INSTALLATION RECOMMENDATIONS Basic damage prevention consists of minimizing generation, discharging any accumulated static charge on your body and preventing that discharge from being sent to or through any electronic component. Uninsulated dangerous voltage are inside the enclosure, voltage that may be sufficient to constitute a risk of shock. Always disconnect to AC Mains before removing the top cover 8.
FIRST INSTALLATION RECOMMENDATIONS 8.5 VENTILATION The equipment will operate as a free-standing unit without requiring any special cooling arrangement. However, slots and openings in the product are provided for ventilation. They ensure reliable operation of the product, keeping it from overheating. These openings must not be blocked nor covered during operation. YOU MUST LEAVE AT A MINIMUM ONE RACK UNIT OF EMPTY SPACE ABOVE THE EQUIPMENT TO ENHANCE VENTILATION AND TO GET A LONGER EQUIPMENT LIFE.
MACROTEL X1 MACROTEL X2 GENERAL DESCRIPTION 9 MACROTEL X1 MACROTEL X2 GENERAL DESCRIPTION 9.1 N° MACROTEL X1 FRONT PANEL CONTROL NAME FUNCTION 1 LCD DISPLAY Two line LCD Display that shows the status and operating mode of Macrotel X-D1. The technical parameters of each menu are displayed. 2 JOG-SHUTTLE Knob (or JogShuttle) to access the various navigation menus and make changes. Press the JogShuttle to confirm selection. 3 “ESC” KEY 4 “HOOK” KEY Call hook key on the PSTN/POTS line.
MACROTEL X1 MACROTEL X2 GENERAL DESCRIPTION 9.2 N° MACROTEL X1 REAR PANEL FUNCTION CONTROL NAME 1 CLOSING COVER 2 “USB” PORT 3 SERIAL -1 RS232 SERIAL PORT 1 Closing cover. This port is used to remotely control the device using a standard PC. Before connecting this port, it is necessary to connect the device control software contained in the box. Macrotel X1 features 1 serial port to control the device via remote control software.
MACROTEL X1 MACROTEL X2 GENERAL DESCRIPTION As regards the Opto Interface port pinout see the Appendix at the end of this manual. For the operation of each GPI and GPO see the specific section in the next pages of this manual. 5 ANALOG OUTPUT Electronically balanced analog audio output of the hybrid, on Balanced XLR connector, Mono type. The two XLR connectors have the same output signal. 6 ANALOG INPUT Input of telephone hybrid, with electronically balanced XLR connection.
MACROTEL X1 MACROTEL X2 GENERAL DESCRIPTION 9.3 N° MACROTEL X2 FRONT PANEL CONTROL NAME FUNCTION 1 LCD DISPLAY Two line LCD Display that shows the status and operating mode of Macrotel X2. The technical parameters of each menu are displayed. 2 JOG-SHUTTLE Knob (or JogShuttle) to access the various navigation menus and make changes. Press the JogShuttle to confirm selection.
MACROTEL X1 MACROTEL X2 GENERAL DESCRIPTION 9.4 MACROTEL X2 REAR PANEL N° 1 CLOSING COVER 2 “USB” PORT 3 SERIAL 1 – RS232 SERIAL PORT 1 + SERIAL 2 – RS232 SERIAL PORT 2 4 FUNCTION CONTROL NAME “GPIO” PORT Closing cover. This port is used to remotely control the device using a standard PC. Before connecting this port, it is necessary to connect the device control software contained in the box. Macrotel X2 features 2 serial ports to control the device via remote control software.
MACROTEL X1 MACROTEL X2 GENERAL DESCRIPTION As regards the Opto Interface port pinout see the Appendix at the end of this manual. For the operation of each GPI and GPO see the specific section in the next pages of this manual. 5 ANALOG OUTPUT Electronically balanced analog audio output of the hybrid, on Balanced XLR connector, Mono type.
MACROTEL X1 MACROTEL X2 GENERAL DESCRIPTION 8 POWER SUPPLY UNIT The power supply unit features a switch to switch on the device and a power socket. To change the fuse see the relevant chapter; the fuse is inside the device near the switching power supply. The fuse is of the slow blow type, 230 Vac and 2.
INSTALLATION AND USE OF THE CONTROL SOFTWARE 10 INSTALLATION AND USE OF THE CONTROL SOFTWARE The installation procedure of the Macrotel X1 and Macrotel X2 control software is described below. The program runs on all Windows platforms, including Windows Xp sp3, Windows Vista and Windows 7 32-bit and Windows 7 64-bit and Windows 8 Pro 64bit. The control software must be installed before connecting the devices to the USB port.
INSTALLATION AND USE OF THE CONTROL SOFTWARE 5. Select a destination folder or leave folder unchanged, click NEXT and then INSTALL 6. The software will start installing the program on the PC; during the installation a request for confirmation to install the USB drivers for the connection to the Macrotel X1 – X2 device will appear. 7. At the end of the installation this page will appear; click Finish and two new icons will be created on the desktop: a. b. 8. Axel Telephone Hybrid Remoter v2.
USE OF THE HYBRID ADDRESS MANAGER SOFTWARE 11 USE OF THE HYBRID ADDRESS MANAGER SOFTWARE The Hybrid Address Manager software is used to assign to Macrotel X1 and Macrotel X2 a Target ID, to lock the front panel and set a Target Name. This can be achieved using either the PC’s Serial port or the USB port. The following screen will appear when you open the program: The Hybrid Address Manager is still disconnected from the Macrotel device. Click CONNECT to establish a connection between the PC and Macrotel.
USE OF THE SOFTWARE HYBRID REMOTER 12 USE OF THE SOFTWARE HYBRID REMOTER Start page of the control software of Macrotel X1 and Macrotel X2 12.1 ACCESS VIA USB AND SERIAL CONNECTION To operate on the Macrotel, after having allocated the TCP/IP port values using the Hybrid Address Manager it is necessary to use the Axel Telephone Hybrid Remoter program by clicking the special icon. The window below shows the connection between Macrotel and the PC via the Virtual USB serial port.
MACROTEL CONTROL VIA SOFTWARE 13 MACROTEL CONTROL VIA SOFTWARE Axel Telephone Hybrid Remoter is a program to manage Macrotel X1 and Macrotel X2 both locally (via serial or USB connection) and remotely via TCP/IP connection. As regards the monitoring functions, the front panel also shows the Send and Receive levels and primary functions such as line hook, ducking, attenuation and hold.
DETAIL OF HYBRID REMOTER FOR MACROTEL X1 14 DETAIL OF HYBRID REMOTER FOR MACROTEL X1 14.1 DESCRIPTION OF MACROTEL X1 CONTROL SOFTWARE The Macrotel control software (Hybrid Remoter) is basically divided into 4 parts: 1. 2. 3. 4. Hybrid section Levels section GPI / GPO status section Setup & Disconnect section 14.2 HYBRID SECTION The “Hybrid Section” features a series of operating and monitoring controls relating to the telephone hybrid connected to a PSTN/POTS line.
DETAIL OF HYBRID REMOTER FOR MACROTEL X1 ATTEN: when ATTEN is pressed, a dB reduction equal to the “Attenuation” value set in the control software is applied to the Receive signal. HOLD: when HOLD is pressed via software the Receive (Rx) volume is taken to –infinity without closing the call. DIAL: when DIAL is pressed the DTMF dialler opens. Dial the number using the numerical keyboard of your PC and then click ON HOOK. In this way the DTMF dials the number to be called on the telephone line.
DETAIL OF HYBRID REMOTER FOR MACROTEL X1 14.4 GPI / GPO STATUS SECTION The GPI / GPO Status section shows the status of the General Purpose Input and Output status. The 15 pin HD female SubD port on the back of the device is used to connect the device; see the technical appendix for the connections and the pinout. 14.4.
DETAIL OF HYBRID REMOTER FOR MACROTEL X1 14.5.1 Hybrid 1 Section (featured on Macrotel X1 and Macrotel X2) In this section all the parameters relating to the Hybrid-1 (Hybrid 1) of Macrotel X1 and Macrotel X2 can be set. INPUT SOURCE: This is the input of the Hybrid 1, i.e. what is sent (SEND) to the telephone interlocutor. The options available are: Analog, Microphone and Tone Generator. ANALOG SENSITIVITY: this is the sensitivity of the balanced analog input. Range of allowed values: from -12.
DETAIL OF HYBRID REMOTER FOR MACROTEL X1 Echo Tail: this is the value in ms of the Echo which is eliminated by the DSP of Macrotel X1 and Macrotel X2. It is combined with the Echo Cancelling control that adjusts the echo cancelling speed on the telephone line. This parameter acts on an automatic variation filter to cancel the echo. The operating parameters self-adapt to the status of the line, of the input and output levels.
DETAIL OF HYBRID REMOTER FOR MACROTEL X1 14.5.2 Hybrid 2 Section (featured only on Macrotel X2) In this section all the parameters relating to the Hybrid-2 (Hybrid 2) of Macrotel X2 can be set. INPUT SOURCE: This is the input of the Hybrid 1, i.e. what is sent (SEND) to the telephone interlocutor. The options available are: Analog, Microphone and Tone Generator. ANALOG SENSITIVITY: this is the sensitivity of the balanced analog input. Range of allowed values: from -12.0 dBu to a maximum of +12.
DETAIL OF HYBRID REMOTER FOR MACROTEL X1 Echo Tail: this is the value in ms of the Echo which is eliminated by the DSP of Macrotel X1 and Macrotel X2. It is combined with the Echo Cancelling control that adjusts the echo cancelling speed on the telephone line. This parameter acts on an automatic variation filter to cancel the echo. The operating parameters self-adapt to the status of the line, of the input and output levels.
DETAIL OF HYBRID REMOTER FOR MACROTEL X1 14.5.3 Macrotel X1 Output Section The Output section of the Macrotel X1 control software shows the Analogic Output control, i.e. the nominal output level. Range of allowed values: from -10.0 dBu to a maximum of +14.0 dBu in 0.1 dBu/steps. 14.5.4 Macrotel X2 Output Section The Output section of the Macrotel X2 control software shows the Analogic Output control, i.e. the nominal output level. Range of allowed values: from -10.0 dBu to a maximum of +14.0 dBu in 0.
DETAIL OF HYBRID REMOTER FOR MACROTEL X1 14.5.5 Macrotel X1 and Macrotel X2 Program Settings section The Program Settings section shows all the functions of the Hybrid Remoter Control Software and of the Macrotel X1 and Macrotel X2 devices. Visualisation & Program Features: The “Show peak meter” checkbox offers the possibility to see the peak meter on the levels section of the two Hybrids.
DETAIL OF PHONEX REMOTER FOR MACROTEL X2 15 DETAIL OF PHONEX REMOTER FOR MACROTEL X2 15.1 DESCRIPTION OF MACROTEL X2 CONTROL SOFTWARE The Macrotel X2 control software (Hybrid Remoter) is basically divided into 5 parts: 1. 2. 3. 4. 5. Hybrid 1 section Hybrid 2 section Levels section GPI / GPO status section Setup & Disconnect section 15.2 HYBRID 1 SECTION The “Hybrid 1 Section” features a series of operating and monitoring controls relating to the telephone hybrid 1 connected to a PSTN/POTS line.
DETAIL OF PHONEX REMOTER FOR MACROTEL X2 ATTEN: when ATTEN is pressed, a dB reduction equal to the “Attenuation” value set in the control software is applied to the Receive signal. The ATTEN control becomes YELLOW. HOLD: when HOLD is pressed via software the Receive (Rx) volume is taken to –infinity without closing the call. The HOLD control becomes RED. DIAL: when DIAL is pressed the DTMF dialler opens. Dial the number using the numerical keyboard of your PC and then click ON HOOK.
DETAIL OF PHONEX REMOTER FOR MACROTEL X2 15.4 GPI / GPO STATUS SECTION The GPI / GPO Status section shows the status of the General Purpose Input and Output status. The 15 pin HD female SubD port on the back of the device is used to connect the device; see the technical appendix for the connections and the pinout. 15.4.
MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE 16 MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE 16.1 TELEPHONE HYBRID CONCEPT The hybrid phone is a device capable of interfacing with a telephone line of audio lines. In practice, the audio signals sent toward the hybrid are received from the phone, and vice versa. The telephone hybrid is widely used in radio and television, as it allows you to create simple audio connections with remote locations in a very low cost.
MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE 16.3 CONNECTION TO THE POTS / PSTN TELEPHONE LINE CHECK that this device is connected to POTS / PSTN lines (analog) DO NOT CONNECT this device to digital VoIP telephone lines DO NOT CONNECT this device to ADSL lines, even if fitted with filter. To avoid any type of hum at 50 Hz and to comply with EMC requirements, the device must be connected to earth by means of the earthing screw on the rear panel or via the power supply cable.
MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE The telephone line from the central office must be connected to the “LINE” connector; a normal telephone set can be connected in parallel to the phone line using the “SET” connector, for example to make calls. Please note that this socket is NOT always active; it depends on the status of the ‘Hook’ key of each Hybrid. When the Hook key is pressed the “SET” socket is not active. The SET socket has the same pinout as the “LINE” socket.
MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE 16.4 WIRELESS CONNECTION VIA GSM MODULE 1 AND GSM MODULE 2 Up to two GSM devices can be connected to Macrotel X1 and Macrotel X2 with mute exchange between the POTS/PSTN line and the GSM line. See the LINE TYPE section for the mute exchange of this line. The image below shows how to connect the GSM-1 AND GSM-2 modules. Cable A-1 is an Audio cable with an RJ10 on one end directly connected to the “GSM” port of LINE 1 of the Macrotel X1.
MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE 16.5 AUDIO CONNECTIONS TO AND FROM PHONEX Macrotel X1 and Macrotel X2 can be connected to other devices such as Mixers or digital consoles in different ways. Macrotel X2 features two possible types of connections, the Single Mode or the Conference Mode. Both are detailed below. The following connections are available in Single Mode: a. Analog connection in Single Mode with one telephone line (Macrotel X1). b.
MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE 16.7 ANALOG CONNECTION IN SINGLE MODE WITH TWO TELEPHONE LINES (MACROTEL X2). In this mode the Macrotel X2 device is connected to the console using an analog audio line. The first telephone hybrid is connected to the Telco N-1 SEND output of the Mixer. The audio signal is sent to the Analog Input 1 of Macrotel X2. The output of Macrotel X2 is sent to the Telco RECEIVE module related to Hybrid 1.
MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE 16.8 ANALOG CONNECTION, IN CONFERENCE MODE, WITH 2 TELEP. LINES AND 3 MACROTEL DEVICES. This mode exploits the maximum modularity of the Macrotel X2 device. All the hybrids are connected to each other in “cascade” and all the Macrotel X2 devices can be controlled from the console simply using one single Telco N-1 channel. The Conference mode on the Analog Output of each Hybrid must be enabled to operate in this mode.
MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE 16.9 CONNECTION TO A NON-BROADCAST MIXING CONSOLE -1 This way of connecting the Macrotel or Phonex telephone hybrid, allows the user to connect a “not broadcast” mixing console. In the example above this console not having all the functionality of a console "Broadcast" feature offers a service to connect directly to the telephone hybrid mixer.
MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE 16.10 CONNECTION TO A NON-BROADCAST MIXING CONSOLE -2 This way of connecting the Macrotel or Phonex, allows users to connect a mixing console that is not “broadcast”. In the example above it is possible to understand that the console in use is completely devoid of the functionality of TELCO, Mix-Minus or N-1. At this point the service of Telco must be created, and executed with what it has available, namely the AUX bus.
MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE 16.11 CONNECTION TO A DIGITAL LINE OR VOIP -1 It is not technically possible to directly connect a VoIP hybrid phone directly. You must insert between VoIP and Telephone Hybrid a A.T.A device 16.11.1 What is a A.T.
MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE 16.12 CONNECTION TO A DIGITAL LINE OR VOIP -2 In the event you need to connect a digital line to a hybrid phone, you must enter an ATA which means Analog telephone adapter, or an adapter between a digital line PSTN analog. Each manufacturer has its general, although some still exist generics on the market. Contact your phone service provider for the installation of the same. In the above example an adapter to ONE SINGLE LINE.
MACROTEL X1 - MACROTEL X2 CONNECTION PROCEDURE 16.13 CONNECTION TO A DIGITAL LINE OR VOIP -3 In the event you need to connect a digital line to a hybrid phone, you must enter an ATA which means Analog telephone adapter, or an adapter between a digital line PSTN analog. Each manufacturer has its general, although some still exist generics on the market. Contact your phone service provider for the installation of the same. In the above example an adapter for multiple output lines.
TECHNICAL APPENDIX 17 TECHNICAL APPENDIX This section provides all the technical explanations, and the connection pin outs to and from the Macrotel X1 and Macrotel X2 device. Always refer to this technical appendix for connections and connection procedures. In case of differences between the documentation below and the hardware device please contact Axel Technology at the numbers and e-mail addresses shown at the end of this manual. Our technical and assistance department will be pleased to help you! 17.
TECHNICAL APPENDIX 17.
TECHNICAL APPENDIX 17.4 APPENDIX D – GPIO PORT The SubD connector 15pole HD GPIO place on the rear of Macrotel, provides 4 inputs General Purpose and 4 outputs General Purpose binary. The inputs are polarized on Opto coupler while the outputs are open collector. They can be used to send commands to Macrotel and perform certain functions. The inputs are constituted by photocouplers polarized on each input and is always inserted, inside, a protection resistor 150 ohms in series.
TECHNICAL APPENDIX 17.4.2 Connection to GPIn and GPOut via external activation (TTL) As shown in the diagram below, taking the voltage externally apparatus it is possible to polarize a photo coupler and implement one of the 4 GP Input available. Note: in this case the masses of the TTL signals generators are common.
TECHNICAL APPENDIX 17.4.3 Connection to GPIn and GPOut via external activation -2 (TTL) As shown in the diagram below, taking the voltage externally apparatus it is possible to polarize a photo coupler and implement one of the 4 GP Input available. Note: in this case the masses of the TTL signals generators are common.
TECHNICAL APPENDIX 17.4.4 Operative Example For the function of each GPO see the Program Settings section, from where various functions can be assigned to the GPOs.
APPENDIX E –FIRMWARE UPDATE PROCEDURE 18 APPENDIX E –FIRMWARE UPDATE PROCEDURE The most recent firmware version is installed by the manufacturer on the Telephone Hybrids Macrotel X1 and Macrotel X2 before they are delivered. Once purchased, the firmware can be updated with the latest version available. The Firmware Upgrade can be carried using the Windows operating system. The suitable operating systems are: Windows Xp Sp3, Windows Vista and Windows 7 Ultimate 32/64 Bit. Check that Microsoft .
APPENDIX E –FIRMWARE UPDATE PROCEDURE f. The following page will appear: g. h. i. j. Select the PC serial port on the screen Switch off the Macrotel X1 or Macrotel X2 device Switch on the Macrotel X1 or Macrotel X2 device and within 3 seconds from when it switches on click CONNECT Once the software is connected to the Macrotel X1 and Macrotel X2 devices the following page will appear: At the same time the front display of the device remains completely blank, without showing anything. k.
TECHNICAL SPECIFICATION MACROTEL X1 – MACROTEL X2 19 TECHNICAL SPECIFICATION MACROTEL X1 – MACROTEL X2 GENERAL VALUE Dimension AC Rate Type of power supply Processing architecture 434x351x44mm (1 rack unit) 230Vac / 110Vac 50 Hz / 60 Hz 30VA Switching power supply Fully digital, based on DSP 24bit/100Mhz.
WEEE Directive – Informativa RAEE 20 WEEE Directive – Informativa RAEE In line with EU Directive 2002/96/EC for waste electrical and electronic equipment (WEEE), this electrical product must not be disposed of as unsorted municipal waste. Please dispose of this product by returning it to the point of sale or to your local municipal collection point for recycling.
GUARANTEE 21 GUARANTEE The product is covered by a one year guarantee ex-works by the manufacturer. Do not open the device. The guarantee shall not be valid if the guarantee seals are broken. The manufacturer shall not be liable for damages of any type deriving from or in relation to the incorrect use of the product.
FINAL NOTES AND AXEL TECHNOLOGY CONTACT DETAILS 23 FINAL NOTES AND AXEL TECHNOLOGY CONTACT DETAILS ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________