User Manual
Table Of Contents
- 1. INTRODUCTION
- 1.1 Scope and Purpose of document
- 1.2 Limitation of Liability Notice
- 2. SAFETY CONSIDERATIONS
- 3. MASTER SITE RACKS (50-078001)
- 3.1 Master Site Description
- 3.P Master Site Rack Photos
- 3.2 Master Site Electrical Specification
- 3.3 Master Site Mechanical Specifications
- 3.4 Master Site Parts List (50-078001)
- 3.5 Channel Frequency Listing
- 3.6 Master Site Drawings
- 3.7 800MHz Air I/F + BSCE Uplink Shelf (50-078002)
- 3.8 800MHz 8Ch. Channel Module Sub-Rack (50-078003)
- 3.9 800MHz 40Watt Power Amplifier/Driver Shelf (50-078004)
- 3.10 VHF Simplex Shelf (50-078010/1)
- 3.11 VHF Simplex Shelf (50-078010/2)
- 3.12 VHF Duplex Shelves (50-078011/1-4)
- 3.13 VHF Air Interface Shelf (50-078012)
- 3.14 VHF Combiner Shelf (50-078013)
- 3.15 VHF PSU Shelf (50-078014)
- 3.16 VHF/800MHz Tx Multi-coupler (50-078015)
- 4. BAND SELECTIVE BI-DIRECTIONAL LINE AMPLIFIER
- 5. MASTER SITE UPGRADE
- 5.1 Master Site Upgrade Rack Assembly (50-078021)
- 5.1.1 Master Site Upgrade Rack Description
- 5.1.2 Master Site Upgrade Rack Electrical Specification
- 5.1.3 Master Site Upgrade Rack Mechanical Specification
- 5.1.6 Master Site Upgrade Rack Assembly (50-078021) Parts List
- 5.1.6a Upgrade Channel Module Shelf/Sub-Rack 50-078023 Parts List
- 5.1.7 Master Site Upgrade System Diagram, Drg. # 50-078081
- 5.2 Upgrade Channel Frequencies
- 5.3 Master Site HPA Interface Shelf (50-078005)
- 5.4 High Power Amplifier Shelf (50-146703)
- 5.1 Master Site Upgrade Rack Assembly (50-078021)
- 6. INSTALLATION
- 7. MAINTENANCE
- APPENDIX A
- APPENDIX B Initial Equipment Set-up Calculations
- APPENDIX C - BATTERY BACKUP
- C.1 GENERAL DESCRIPTION
- C.2. BATTERY BACKUP PHOTOGRAPHS
- C.3. SPECIFICATION
- C.4. GENERAL DRAWINGS
- C.5. BBU ALARMS & MONITORING SYSTEM
- C.6. INSTALLATION
- _
- C.7. MAINTENANCE
Mission Valley Radio Repeater Equipment + UpgradeUser/Maintenance Handbook
APPENDIX C Battery Backup
Handbook No. 50-078021HBKM Page 78 of 85
C.3. SPECIFICATION
C.3.1 Technical Specification
PARAMETER SPECIFICATION
Input Voltage:
Main SMPSU:-
90 Vac to 264 Vac Universal Input.
Battery Charger:-
93-132 Vac and 187-264 Vac
Switch selectable
Input Frequency: 47 to 63 H
Input Current: <2.0 A typical at 230 Vac (8.0A maximum
when charging batteries after extended
mains outage at 110 Vac)
Rating Of SMPSU: 27A at 30°C, 21A at 55°C.
Output (Load) Voltage: +12.5V DC
Output (Load) Current: 9A (typical)*
Battery Run Time: 8 hours (typical)*
Batteries: 4 x 12V, 40Amp/hour*
Low Voltage Cut-off Point: 10.5V
Standard Alarms:
1: Power supply alarms
2: Door open alarm
3: AC supply failure alarm
Optional Alarms Available:
4. Temperature alarm
* The load current will vary depending on the exact model of Cell Enhancer being driven
from the power supply. Although 9 Amps is a typical figure, models with higher power
amplifiers or more gain draw more current. This will be reflected in the battery run time.
C.3.2 Mechanical Specification
PARAMETER SPECIFICATION
Height:
620mm
Width:
420mm
Case size
Depth:
250mm
(excluding heatsinks, connectors, handles and feet)
Fixings:
4 holes on 470(w) x 500(h)mm
operational:
-30°C to +55°C
Temperature
Range:
storage:
-40°C to +70°C
Weight:
75kg (approximately)
RF Connectors:
N type female
Environmental Protection:
IP65 (with door closed and all ports terminated)
Case:
To RAL 7035
Heatsinks:
Matt black (where fitted)
Finish:
Handles:
Black Technopolymer
Supply Cable:
Unit supplied with suitable supply input leads with
connector and appropriate length of cable (where
appropriate)