User Manual
Table Of Contents
- 1. INTRODUCTION
- Scope and Purpose of Document
- Limitation of Liability Notice
- 2. SAFETY CONSIDERATIONS
- 3. EQUIPMENT OVERVIEW
- 4. SUB-UNIT MODULES
- 4.1 Bandpass Filter (02-010201)
- 4.2 Two-Way Splitter (07-002503)
- 4.3 0.25Watt 0- -30dB Switched Attenuator (10-000703)
- 4.4 11-007302 & 11-007402 Low Noise Amplifiers
- 4.4.1 Description
- 4.4.2 Technical Specification (11-007302)
- 4.4.3 Technical Specification (11-007402)
- 4.4.4 LNA ‘D’ Connector Pin-out details
- 4.4.5 Drg. # 11-007302, LNA Assembly With Alarm Relay
- 4.4.6 Drg. # 11-007370, LNA RF Circuit Diagram
- 4.4.7 Drg. # 11-007371, LNA DC Wiring Diagram
- 4.4.8 Drg. # 11-003971, LNA DC Circuit Diagram
- 4.4.9 Drg. # 11-007402, LNA Assembly With Alarm Relay
- 4.4.10 Drg. # 11-007470, LNA RF Circuit Diagram
- 4.5 12-021601 5Watt Medium Power Tetra Amplifier
- 4.6 12-022101 10Watt Power Tetra Amplifier
- 4.7 8A Mains Filter Assembly (13-003301)
- 4.8 Channel Control Module (17-002101)
- 4.9 Channel Selective Module (17-003007)
- 4.10 12V Single Relay Board (80-008901)
- 4.11 12V Switch-Mode PSU (96-300052)
- 5. INSTALLATION
- 6. FAULT FINDING & MAINTENANCE
- 6.1 General Fault Finding Procedures
- 6.2 Downlink
- 6.3 Uplink
- 6.4 Fault repair
- 6.5 Checking service
- 6.6 Service Support
- 6.7 Tools & Test Equipment
- 6.8 General Maintenance Procedures
- _
- 6.9 Module Removal (LNA’s, general procedure)
- 6.10 Module Replacement (general)
- 6.11 Power Amplifiers
- 6.12 Low Power Amplifier Replacement
- 6.13 Module Transportation
- APPENDIX A
- _
- APPENDIX B
Two Channel UHF Cell Enhancer
User Handbook
Handbook Number: 50-187601HBKM Page: 31 of 51
4.6 12-022101 10Watt Power Tetra Amplifier
4.6.1 Description
The power amplifier fitted to this unit is a multi-stage, solid state power amplifier. Class A circuitry is
employed throughout the device to ensure excellent linearity over a wide dynamic frequency range.
All the semi-conductor devices are very conservatively rated to ensure low device junction
temperatures and a long, trouble free working lifetime.
The power amplifier should require no maintenance over its operating life. Under no circumstances
should the cover be removed or the side adjustments disturbed unless it is certain that the amplifier
has failed; since it is critically aligned during manufacture and any re-alignment will require extensive
test equipment.
4.6.2 Technical Specification
PARAMETER SPECIFICATION
Frequency range: 380-470MHz (as required)
Bandwidth: 10-40MHz (typical, tuned to spec.)
Maximum RF output: >10Watts
Gain: >34dB
1dB compression point: +40.3dBm
3
rd
order intercept point: +54dBm
Return loss: >18dB
VSWR: better than 1.5:1
Connectors: SMA female
Supply: 4.3A @ 12V DC
Weight: 1kg (excluding heatsink)
Alarm: Load current alarm (relay contacts)
operational:
-10°C to +60°C Temperature
range:
storage:
-20°C to +70°C