User Manual
Table Of Contents
- 1. INTRODUCTION
- Scope and Purpose of Document
- Limitation of Liability Notice
- 2. SAFETY CONSIDERATIONS
- 3. EQUIPMENT OVERVIEW
- 4. SUB-UNIT MODULES
- 4.1 Bandpass Filter (02-010201)
- 4.2 Two-Way Splitter (07-002503)
- 4.3 0.25Watt 0- -30dB Switched Attenuator (10-000703)
- 4.4 11-007302 & 11-007402 Low Noise Amplifiers
- 4.4.1 Description
- 4.4.2 Technical Specification (11-007302)
- 4.4.3 Technical Specification (11-007402)
- 4.4.4 LNA ‘D’ Connector Pin-out details
- 4.4.5 Drg. # 11-007302, LNA Assembly With Alarm Relay
- 4.4.6 Drg. # 11-007370, LNA RF Circuit Diagram
- 4.4.7 Drg. # 11-007371, LNA DC Wiring Diagram
- 4.4.8 Drg. # 11-003971, LNA DC Circuit Diagram
- 4.4.9 Drg. # 11-007402, LNA Assembly With Alarm Relay
- 4.4.10 Drg. # 11-007470, LNA RF Circuit Diagram
- 4.5 12-021601 5Watt Medium Power Tetra Amplifier
- 4.6 12-022101 10Watt Power Tetra Amplifier
- 4.7 8A Mains Filter Assembly (13-003301)
- 4.8 Channel Control Module (17-002101)
- 4.9 Channel Selective Module (17-003007)
- 4.10 12V Single Relay Board (80-008901)
- 4.11 12V Switch-Mode PSU (96-300052)
- 5. INSTALLATION
- 6. FAULT FINDING & MAINTENANCE
- 6.1 General Fault Finding Procedures
- 6.2 Downlink
- 6.3 Uplink
- 6.4 Fault repair
- 6.5 Checking service
- 6.6 Service Support
- 6.7 Tools & Test Equipment
- 6.8 General Maintenance Procedures
- _
- 6.9 Module Removal (LNA’s, general procedure)
- 6.10 Module Replacement (general)
- 6.11 Power Amplifiers
- 6.12 Low Power Amplifier Replacement
- 6.13 Module Transportation
- APPENDIX A
- _
- APPENDIX B
Two Channel UHF Cell Enhancer
User Handbook
Handbook Number: 50-187601HBKM Page: 51 of 51
APPENDIX B
Initial Equipment Set-Up Calculations
General Information
Site Name: Client Name:
Date: AFL Equip. Model No.
Antenna Systems
Model Gain Azimuth Comments
A - Service Antenna
B – Donor Antenna
Type Loss Length Comments
C – Service Feeder
D – Donor Feeder
Initial Parameters
E – CE Output Power dBm
F – Antenna Isolation dB
G – Input signal level from donor BTS dBm
Operating Voltage V
Downlink Calculations
Parameter Comments Value
Input signal level (G) dBm
CE max. o/p power (E) dBm
Gain setting E - G dB
Isolation required (Gain + 10dB) dB
Service antenna gain (A) dB
Service antenna feeder loss (C) dB
Effective radiated power (ERP) E+A-C dBm
Attenuator setting CE gain-gain setting dB
If the input signal level in the uplink path is known and steady, use the following calculation table to
determine the gain setting. If the CE features Automatic Gain Control the attenuator should be set to
zero and if not, then the attenuation setting for both uplink and downlink should be similar.
Uplink Calculations
Parameter Comments Value
Input signal level dBm
CE max. o/p power (E) dBm
Gain setting dB
Required isolation dB
Donor antenna gain (B) dB
Donor antenna feeder loss (D) dB
Effective radiated power (ERP) E+B-D dBm
Attenuator setting (CE gain-gain setting) dB