5.4.1.14. 12V Switch-Mode PSU (96-300052)
No routine maintenance of the PSU is required. If a fault is suspected, then the output voltage from
the power supply may be measured on its output terminals. This is typically set to 12.2V. The
adjustment potentiometer will be found close to the DC output terminals.
All the PSUs used in AFL Cell Enhancers are capable of operation from either 110 or 220V nominal
AC supplies. The line voltage is sensed automatically, so no adjustment or link setting is needed by
the operator.
96-300052 Specification
AC Input Supply
110 or 220V nominal
Voltage
85 - 265V AC
(absolute limits)
Frequency 47 to 63Hz
DC Output Supply
12V DC (nominal)
Voltage
10.5-13.8V (absolute limits)
Current 12.5A