WMATA CRCS Redundant Antenna System General Overview Handbook For GPD Telecom Inc. AWL Works Order Q119862 AWL Product Part Nos.
Table of Contents 1. Introduction .................................................................................................................................... 5 1.1. Scope and Purpose of Document................................................................................................... 5 1.2. Limitation of Liability Notice ............................................................................................................ 5 2. Safety Considerations ...................................
4.6.2. 8 Ch. Squelch Gated BDA 60-228705 Specification ................................................................. 39 4.6.3. 8 Ch. Squelch Gated BDA 60-228705 System Diagram ........................................................... 41 4.6.3.1. 8 Ch. Squelch Gated BDA 60-228705 Alarm Wiring Diagram............................................... 42 4.6.4. 8 Ch. Squelch Gated BDA 60-228705 Front View .................................................................... 43 4.6.5. 8 Ch.
5.12.4.1. RF Failover Switch Unit 60-228905 Alarm Outputs............................................................... 84 5.12.5. RF Failover Switch Unit 60-228905 Front View .................................................................... 85 5.12.6. RF Failover Switch Unit 60-228905 Rear View ..................................................................... 86 5.13. Combiner Unit 60-228906 ............................................................................................................
1. Introduction 1.1. Scope and Purpose of Document This handbook is for use solely with the equipment identified by the Axell Wireless Limited (AWL) Part Number shown on the front page. It is not to be used with any other equipment unless specifically authorized by AWL. This is a controlled release document and, as such, becomes a part of the Axell Wireless Total Quality Management System. Alterations and modification may therefore only be performed by Axell Wireless.
2. Safety Considerations 2.1. Earthing of Equipment Equipment supplied from the mains must be connected to grounded outlets and earthed in conformity with appropriate local, national and international electricity supply and safety regulations. 2.2.
2.5. Chemical Hazard Beryllium Oxide, also known as Beryllium Monoxide, or Thermalox™, is sometimes used in devices within equipment produced by Axell Wireless Ltd. Beryllium oxide dust can be toxic if inhaled, leading to chronic respiratory problems. It is harmless if ingested or by contact. Products that contain beryllium are load terminations (dummy loads) and some power amplifiers. These products can be identified by a yellow and black “skull and crossbones” danger symbol (shown above).
3. 60-228801 - WMATA Jackson Graham Building CRAS System The WMATA Jackson Graham Building CRAS System consists of the following equipment: Part No. 60-228703 Part No. 60-091705 Dual Fiber Optic Unit Dual Redundant PSU The Jackson Graham Building CRAS System provides the Primary Downlink to and receives the Primary Uplink signal from the Gallery Place Station CRAS System.
3.2.
3.3. Dual Fiber Optic Unit 60-228703 Dual Fiber Optic Unit 60-228703 is built into a 2U, 19” rack-mount case. The Main Primary Downlink RF path from the BTS enters the Dual Fiber Optic Unit via the N type port labeled “TX 1” (annotated “A” in section 3.3.4.) and then passes through a 20dB Directional Coupler 90852420 which couples off a small portion of the signal and feeds it to the N type port labeled “MON -20dB TX 1” (annotated “B” in section 3.3.4.
3.3.1. Dual Fiber Optic Unit 60-228703 List of Major Sub-Components Component Part 20-001601 20-005401 20-005501 96-110013 96-200024 90-852420 94-100003 3.3.2. Part Description 12V Dual Relay Board Fiber Optic Transmitter Module Fiber Optic Receiver Module 3.15 A Fuse DC/DC Converter 20dB Directional Coupler Power Diode Qty Per Assembly 1 2 2 2 2 4 3 Dual Fiber Optic Unit 60-228703 Specification PARAMETER RF Downlink SPECIFICATION 489.5MHz to 491.0MHz 496.3MHz to 496.
3.3.3.
3.3.3.1. Dual Fiber Optic Unit 60-228703 Alarm Outputs 15 pin “D” panel plug “ALARM”, local alarm output to Krone terminal block on rack (annotated “EE” in section 3.3.3.
3.3.4. Dual Fiber Optic Unit 60-228703 Front View N C G TX B I A H MON -20dB TX 1 MON -20dB RX 1 TX 1 RX 1 MON -20dB TX 2 MON -20dB RX 2 TX 2 RX 2 Q O S R W CC BB 12V T3.15A 24V T3.
3.3.5. Dual Fiber Optic Unit 60-228703 Rear View A Axell Wireless Limited Technical Literature Document Number 60-228701HBK Earthing connection WMATA CRCS Redundant Antenna System General Overview Issue No.
3.3.6. Dual Fiber Optic Unit 60-228703 DC Inlet The Dual Fiber Optic Unit 60-228703 is a standard module used in three different locations: the Jackson Graham Building, the Carmen Turner Facility and the Gallery Place Station.
3.4. Dual Redundant PSU 60-091705 Dual Redundant PSU 60-091705 is built into a 4U, 19” rack-mount case. The PSU case houses two mains driven PSU modules whose outputs are parallel combined using high power, low volt-drop diodes. This means that if either supply fails the other will seamlessly take over all power provision until the fault is rectified. Both supplies’ outputs are monitored and an alarm will become active should either module fail. 3.4.1.
3.4.3. Dual Redundant PSU 60-091705 System Diagram Axell Wireless Limited Technical Literature Document Number 60-228701HBK WMATA CRCS Redundant Antenna System General Overview Issue No.
3.4.4. Dual Redundant PSU 60-091705 Front View POWER ALARM A A B 3.4.5.
4. 60-228701 - WMATA Carmen Turner Facility CRAS System The WMATA Carmen Turner Facility CRAS System consists of the following equipment mounted in a 41U, 19” equipment housing rack Part No. 96-300090 PSU Housing Shelf Contains Qty. 2, Part No. 96-300091 PSU Modules Part No. 60-228703 Dual Fiber Optic Unit Part No. 60-228702 Splitter/Combiner Unit Part No. 60-228706 Quadplexer (Base) Part No. 60-228706 Quadplexer (DAS) Part No. 60-228704 8 Ch. Squelch Gated BDA (Band 1) Part No. 60-228705 8 Ch.
4.1. 60-228701 List of Major Sub-Components Component Part 60-228706 60-228704 60-228705 60-228702 60-228703 60-228706 96-300090 96-300091 97-500424 Component Part Description Quadplexer (Base) 8 Ch. Squelch Gated BDA (Band 1) 8 Ch.
60-228701 System Diagram Controller H56 PC Control System Monitoring Point Alarm 4.2. Controller H56 Alarm/Battery Alarm/Battery Axell Wireless Limited Technical Literature Document Number 60-228701HBK WMATA CRCS Redundant Antenna System General Overview Issue No.
4.3. 60-228701 Rack Elevations 4.3.1 Rack Front View A B C D E F G H I PSU Housing Shelf 96-300090 Dual Fiber Optic Unit 60-228703 Splitter/Combiner Unit 60-228702 Quadplexer (Base) 60-228706 Quadplexer (DAS) 60-228706 8 Ch. Squelch Gated BDA 60-228704 8 Ch. Squelch Gated BDA 60-228705 1U Blanking Panels 5U Blanking Panel Axell Wireless Limited Technical Literature Document Number 60-228701HBK WMATA CRCS Redundant Antenna System General Overview Issue No.
4.3.2. Rack Rear View L M P Q H N O A I B J K C D E F G A B C D E F G H I J K L M N O P Q Position of PSU Housing Shelf 96-300090 Dual Fiber Optic Unit 60-228703 Splitter/Combiner Unit 60-228702 Quadplexer (Base) 60-228706 Quadplexer (DAS) 60-228706 8 Ch. Squelch Gated BDA 60-228704 8 Ch.
4.3.3.
60-228701 Alarm Wiring Schematic 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Axell Wireless Limited Technical Literature Document Number 60-228701HBK 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 0 0 4.3.4. WMATA CRCS Redundant Antenna System General Overview Issue No.
4.4. Quadplexer (Base) 60-228706 Quadplexer (Base) 60-228706 is built into a 4U, 19” rack-mount case Downlink RF from the BTS enters the rack via the N type connector labeled “BASE PORT” on the rack lid (annotated “A” in section 4.3.3.) and the signal is fed to the N type port on the Quadplexer front panel labeled “BASE” (annotated “A” in section 4.4.4.).
4.4.1. Quadplexer (Base) 60-228706 Major Sub-Components Component Part 02-013401 02-016801 90-852330 4.4.2. Part Description Qty Per Assembly 2 2 1 Bandpass Filter Bandpass Filter 30dB Directional Coupler Quadplexer (Base) 60-228706 Specification PARAMETER Band 1 D/L (Base port to port A) Frequency Range Rejection Insertion Loss Band 1 U/L (port B to Base port) Frequency Range Rejection SPECIFICATION 489.5-491.0 MHz 492.5-494.0 MHz > 65 dB ≤ 3.0 dB 492.5-494.0 MHz 489.5-491.0 MHz > 40 dB 496.3-496.
4.4.3. Quadplexer (Base) 60-228706 System Diagram 02-016801 Port A, Band 1 D/L O/P to 8 Ch. Squelch Gated BDA 60-228704 489.5-491.0 MHz Monitor Port 30dB coupled from U/L O/P 02-016801 Port B, Band 1 U/L I/P from 8 Ch. Squelch Gated BDA 60-228704 492.5-494.0 MHz D/L I/P from BTS U/L O/P to BTS 90-852330 30 dB 02-013401 Port C, Band 2 D/L O/P to 8 Ch. Squelch Gated BDA 60-228705 496.3-496.7 MHz 02-013401 Port D, Band 2 U/L I/P from 8 Ch. Squelch Gated BDA 60-228705 499.3-499.
4.4.4. A B C D E F Quadplexer (Base) 60-228706 Front View N type port “BASE”, Downlink input from and Uplink output to BTS N type port “A”, Band 1 Downlink output to 8 Ch. Squelch Gated BDA 60-228704 N type port “C”, Band 2 Downlink output to 8 Ch. Squelch Gated BDA 60-228705 N type port “B”, Band 1 Uplink input from 8 Ch. Squelch Gated BDA 60-228704 N type port “D”, Band 2 Uplink input from 8 Ch.
4.5. 8 Channel Squelch Gated BDA 60-228704 8 Ch. Squelch Gated BDA 60-228704 is built into an 8U, 19” rack-mount case 60-228704 utilizes Software Defined Radio (SDR) technology to digitally process the signal to define the required channel frequencies and bandwidth (eight channels in the Downlink path and eight in the Uplink path).
4.5.1. 8 Ch. Squelch Gated BDA 60-228704 List of Major Sub-Components Component Part 05-002603 12-026902 19-002202 90-852315 96-110015 E931030 H561003 J1161030 J1421001 R031002 4.5.2. Part Description 3dB Splitter/Combiner 25W Power Amplifier Interconnection Assembly 15dB Directional Coupler 15A Fuse UHF SDR Module (489.25MHz to 494.25MHz) Control Module External Alarm and Battery Module DC/DC Converter Reference Generator Qty Per Assembly 1 2 1 1 1 1 1 1 1 1 8 Ch.
(1) (2) Downlink Channels Channel Number 14 13 2 12 1 11 10 9 Channel Frequency 489.5125 MHz 489.5375 MHz 490.7875 MHz 490.8375 MHz 490.8625 MHz 490.8875 MHz 490.9125 MHz 490.9625 MHz Channel Bandwidth 12.5 kHz 12.5 kHz 25.0 kHz 12.5 kHz 12.5 kHz 12.5 kHz 12.5 kHz 25.0 kHz Channel Number 14 13 2 12 1 11 10 9 Channel Frequency 492.5125 MHz 492.5375 MHz 493.7875 MHz 493.8375 MHz 493.8625 MHz 493.8875 MHz 493.9125 MHz 493.9625 MHz Channel Bandwidth 12.5 kHz 12.5 kHz 25.0 kHz 12.5 kHz 12.5 kHz 12.
Axell Wireless Limited Technical Literature Document Number 60-228701HBK © AWL 2009 Date: 19/11/2009 Aerial House Asheridge Road Chesham Buckinghamshire HP5 2QD United Kingdom Telephone: +44 (0) 1494 777000 Facsimile: +44 (0) 1494 777002 E-Mail: info@axellwireless.com www.axellwireless.com Port B, Band 1 U/L O/P to Quadplexer (BASE) 60-228706 Port A, Band 1 D/L I/P from Quadplexer (BASE) 60-228706 0V 1 +6.
4.5.3.1 8 Ch. Squelch Gated BDA 60-228704 Alarm Wiring Diagram 1 9 Axell Wireless Limited Technical Literature Document Number 60-228701HBK WMATA CRCS Redundant Antenna System General Overview Issue No.
4.5.4. 8 Ch.
4.5.5. 8 Ch. Squelch Gated BDA 60-228704 Rear View 60-228704 A A Axell Wireless Limited Technical Literature Document Number 60-228701HBK Earthing connection WMATA CRCS Redundant Antenna System General Overview Issue No.
4.6. 8 Ch. Squelch Gated BDA 60-228705 8 Ch. Squelch Gated BDA 60-228705 is built into an 8U, 19” rack-mount case. 60-228705 utilizes Software Defined Radio technology to digitally process the signal to define the required channel frequencies and bandwidth (eight channels in the Downlink path and eight in the Uplink path).
4.6.1 8 Ch. Squelch Gated BDA 60-228705 List of Major Sub Components Component Part 05-002603 12-026902 19-002202 90-852315 96-110015 E941030 H561003 J1161030 J1421001 R031002 4.6.2. Part Description 3dB Splitter/Combiner 25W Power Amplifier Interconnection Assembly 15dB Directional Coupler 15A Fuse UHF SDR Module (495.5 - 500.5MHz) Control Module External Alarm and Battery Module DC/DC Converter Reference Generator Qty Per Assembly 1 2 1 1 1 1 1 1 1 1 8 Ch.
(1) (2) Downlink Channels Channel Number 8 3 7 Paging 4 6 15 5 Channel Frequency 496.3375 MHz 496.4375 MHz 496.4875 MHz 496.5125 MHz 496.5375 MHz 496.5626 MHz 496.5875 MHz 496.6125 MHz Channel Bandwidth 25.0 kHz 25.0 kHz 12.5 kHz 12.5 kHz 12.5 kHz 12.5 kHz 12.5 kHz 12.5 kHz Channel Number 8 3 7 Paging 4 6 15 5 Channel Frequency 499.3375 MHz 499.4375 MHz 499.4875 MHz 499.5125 MHz 499.5375 MHz 499.5626 MHz 499.5875 MHz 499.6125 MHz Channel Bandwidth 25.0 kHz 25.0 kHz 12.5 kHz 12.5 kHz 12.5 kHz 12.
Axell Wireless Limited Technical Literature Document Number 60-228701HBK © AWL 2009 Date: 19/11/2009 Aerial House Asheridge Road Chesham Buckinghamshire HP5 2QD United Kingdom Telephone: +44 (0) 1494 777000 Facsimile: +44 (0) 1494 777002 E-Mail: info@axellwireless.com www.axellwireless.com Port B, Band 2 U/L O/P to Quadplexer (BASE) 60-228706 Port A, Band 2 D/L I/P from Quadplexer (BASE) 60-228706 0V +6.
Axell Wireless Limited Technical Literature Document Number 60-228701HBK © AWL 2009 Date: 30/11/2009 Aerial House Asheridge Road Chesham Buckinghamshire HP5 2QD United Kingdom Telephone: +44 (0) 1494 777000 Facsimile: +44 (0) 1494 777002 E-Mail: info@axellwireless.com www.axellwireless.com 9 way “D” plug, alarm output on 8 Ch. Squelch Gated BDA 60-228705 GND Blue 8 Ch.
4.6.4. B 8 Ch.
4.6.5. 8 Ch. Squelch Gated BDA 60-228705 Rear View 60-228705 A A Axell Wireless Limited Technical Literature Document Number 60-228701HBK Earthing connection WMATA CRCS Redundant Antenna System General Overview Issue No.
4.7. Splitter/Combiner Unit 60-228702 Splitter/Combiner Unit 60-228702 is built into a 2U, 19” rack-mount case. Band 1 Downlink RF from 8 Ch. Squelch Gated BDA 60-228704 enters the Splitter/Combiner Unit via the N type port labeled “A” (annotated “A” in section 4.7.4.) and passes into the Downlink 3dB Splitter/Combiner 05-002603. Band 2 Downlink RF from 8 Ch. Squelch Gated BDA 60-228705 enters the Splitter/Combiner Unit via the N type port labeled “B” (annotated “B” in section 4.7.4.
4.7.3. Splitter/Combiner Unit 60-228702 System Diagram Port A, Band 1 D/L I/P from 8 Ch. Squelch Gated BDA 60-228704 10-000901 Port TX, D/L O/P to Dual Fibre Optic Unit 60-228703 05-002603 0-15 dB Port A, Band 2 D/L I/P from 8 Ch. Squelch Gated BDA 60-228705 Port C, Band 1 U/L O/P to 8 Ch. Squelch Gated BDA 60-228704 10-000701 Port RX, U/L I/P from Dual Fibre Optic Unit 60-228703 05-002603 Port D, Band 2 U/L O/P to 8 Ch.
4.7.4. A B C D E F 4.7.5. Splitter/Combiner Unit 60-228702 Front View N type port “A”, D/L I/P from 8 Ch. Squelch Gated BDA 60-228704 N type port “B”, D/L I/P from 8 Ch. Squelch Gated BDA 60-228705 N type port “TX” D/L O/P to Dual Fiber Optic Unit 60-228703 N type port “RX” U/L I/P from Dual Fiber Optic Unit 60-228703 N type port “C”, U/L O/P to 8 Ch. Squelch Gated BDA 60-228704 N type port “D”, U/L O/P to 8 Ch.
4.8. Dual Fiber Optic Unit 60-228703 Dual Fiber Optic Unit 60-228703 is built into a 2U, 19” rack-mount case. Downlink RF from Splitter/Combiner Unit 60-228702 enters the Dual Fiber Optic Unit via the N type port labeled “TX 1” (annotated “A” in section 4.8.4.) and passes through a 20dB Directional Coupler 90-852420 which couples off a small portion of the signal and feeds it to the N type port labeled “MON -20dB TX 1” (annotated “B” in section 4.8.4.
4.8.1. Dual Fiber Optic Unit 60-228703 List of Major Sub-Components Component Part 20-001601 20-005401 20-005501 96-110013 96-200024 90-852420 94-100003 4.8.2. Part Description 12V Dual Relay Board Fiber Optic Transmitter Module Fiber Optic Receiver Module 3.15 A Fuse DC/DC Converter 20dB Directional Coupler Power Diode Qty Per Assembly 1 2 2 2 2 4 3 Dual Fiber Optic Unit 60-228703 Specification PARAMETER RF Downlink SPECIFICATION 489.5MHz to 491.0MHz 496.3MHz to 496.
4.8.3.
4.8.3.1. Dual Fiber Optic Unit 60-228703 Alarm Outputs 15 pin “D” panel plug “ALARM”, local alarm output to Krone terminal block on rack (annotated “EE” in section 3.8.4.
4.8.4. Dual Fiber Optic Unit 60-228703 Front View N C G TX B MON -20dB TX 1 MON -20dB RX 1 MON -20dB TX 2 MON -20dB RX 2 I A TX 1 H Q O S R W CC BB 12V T3.15A 24V T3.
4.8.5. Dual Fiber Optic Unit 60-228703 Rear View A Axell Wireless Limited Technical Literature Document Number 60-228701HBK Earthing connection WMATA CRCS Redundant Antenna System General Overview Issue No.
4.9. Quadplexer (DAS) 60-228706 Quadplexer (DAS) 60-228706 is built into a 4U, 19” rack-mount case Band 1 Downlink RF from the 8 Ch. Squelch Gated BDA 60-228704 enters the shelf via the N type port labeled “A” (annotated “A” in section 4.9.4.) and passes through a Bandpass Filter 02-016801 which is tuned to pass the Band 1 Downlink passband of 489.5MHz to 491.0MHz and to reject out-of-band signals and noise.
4.9.1. Quadplexer (DAS) 60-228706 List of Major Sub-Components Component Part 02-013401 02-016801 90-852330 4.9.2. Part Description Qty Per Assembly 2 2 1 Bandpass Filter Bandpass Filter 30dB Directional Coupler Quadplexer (DAS) 60-228706 Specification PARAMETER Band 1 D/L (port A to DAS port) Frequency Range Rejection Insertion Loss Port A to Monitoring port Band 1 U/L (DAS port to port B) Frequency Range SPECIFICATION 489.5-491.0 MHz 492.5-494.0 MHz > 65 dB ≤ 3.0 dB 33dB ±1 dB 492.5-494.0 MHz 489.
4.9.3. Quadplexer (DAS) 60-228706 System Diagram Port A, Band 1 D/L I/P from 8 Ch. Squelch Gated BDA 60-228704 02-016801 489.5-491.0 MHz Monitor Port 30dB coupled from D/L O/P 02-016801 Port B, Band 1 U/L O/P to 8 Ch. Squelch Gated BDA 60-228704 492.5-494.0 MHz 90-852330 30 dB D/L O/P to DAS U/L I/P from DAS 02-013401 Port C, Band 2 D/L I/P from 8 Ch. Squelch Gated BDA 60-228705 496.3-496.7 MHz 02-013401 Port D, Band 2 U/L O/P to 8 Ch. Squelch Gated BDA 60-228705 499.3-499.
4.9.4. A B C D E F Quadplexer (DAS) 60-228706 Front View N type port “A”, Band 1 Downlink input from 8 Ch. Squelch Gated BDA 60-228704 N type port “C”, Band 2 Downlink input from 8 Ch. Squelch Gated BDA 60-228705 N type port “DAS”, Downlink output to and Uplink input from the DAS N type port “MONITORING”, 30dB test/monitor port coupled from the Downlink O/P path N type port “B”, Band 1 Uplink output to 8 Ch. Squelch Gated BDA 60-228704 N type port “D”, Band 2 Uplink output to 8 Ch.
4.10. PSU Housing Shelf 96-300090 This is a 1U, 19” Rack Mount shelf housing two, 960W, fan cooled, AC mains driven PSU modules (96300091) the outputs of which are combined to provide a 24V DC supply to the other chassis in the system. The DC leads connected to the output terminals (annotated “B” and “C” in section 4.10.2.) are terminated with right-angle XLR female connectors which mate with corresponding panel mounting male XLR connectors on the front panels of those units which require a DC input. 4.
4.10.2. PSU Module Chassis 96-300090 Rear View A B C D E 4.10.3. AC inputs 24V DC terminal (connects to rack 24V busbar) 0V DC terminal (connects to rack 0V busbar) Alarm output to Krone terminal block on rack Earthing connector PSU Module Chassis 96-300090 Alarm Wiring 25 pin “D” panel socket, local alarm/control output to Krone terminal block on rack (annotated “D” in section 4.10.2.
4.10.4. DC Connector Details 4.10.4.1. DC Inlet Free Socket These are the free sockets that are connected to the rack busbars A B C D E 5.10.4.2.
5. 60-228901 - WMATA Gallery Place Station CRAS System The WMATA Gallery Place Station CRAS System consists of the following equipment mounted in two 41U, 19” equipment housing racks, each rack is loaded with equipment on both the front and rear aspects. Rack 1 (part No, 60-228902) Front: Part No. 96-300090 PSU Housing Shelf Contains Qty. 2, Part No. 96-300091 PSU Modules Part No. 60-228703 Dual Fiber Optic Unit Part No. 60-228905 RF Failover Switch Unit Part No. 60-228907 Combiner Unit Part No.
The Gallery Place Station CRAS System receives a Primary optical Downlink from the Jackson Graham Building CRAS System and a Redundant optical Downlink from the Carmen Turner Facility CRAS System, both optical Downlink feeds enter the Gallery Place Station CRAS System and are demodulated to RF.
FRONT ELEVATION (DOOR REMOVED) SCALE 1:4 2U BLANK Axell Wireless Limited Technical Literature Document Number 60-228701HBK 1U BLANK PL 28/08/09 AS STATED 1U BLANK 60-228904 4U 16 CHANNEL U/L GATING UNIT 60-228904 4U 16 CHANNEL U/L GATING UNIT 1U BLANK 60-228904 4U 16 CHANNEL U/L GATING UNIT 1U BLANK 60-228904 4U 16 CHANNEL U/L GATING UNIT 60-228904 4U 16 CHANNEL U/L GATING UNIT REAR ELEVATION (DOOR REMOVED) SCALE 1:4 A 1U BLANK 1U BLANK A 60-228904 4U 16 CHANNEL U/L GATING UNIT 1U BLANK
Axell Wireless Limited Technical Literature Document Number 60-228701HBK FRONT ELEVATION (DOOR REMOVED) SCALE 1:4 1U BLANK 60-228904 4U 16 CHANNEL U/L GATING UNIT 1U BLANK 60-228904 4U 16 CHANNEL U/L GATING UNIT 1U BLANK 60-228904 4U 16 CHANNEL U/L GATING UNIT 1U BLANK 60-228904 4U 16 CHANNEL U/L GATING UNIT 1U BLANK 60-228904 4U 16 CHANNEL U/L GATING UNIT 1U BLANK 60-228904 4U 16 CHANNEL U/L GATING UNIT 1U BLANK 60-228904 4U 16 CHANNEL U/L GATING UNIT 60-228906 2U COMBINER UNIT 96-300090 +
5.4. Rack 1 Front View A B C D E F G H I PSU Housing Shelf 96-300090 + Qty. 2, Part No. 96-300091 PSU Modules Dual Fiber Optic Unit 60-228703 RF Failover Switch Unit 60-228905 Combiner Unit 60-228907 16 Ch. DSP U/L Squelch Gate No. 22 16 Ch. DSP U/L Squelch Gate No. 23 16 Ch. DSP U/L Squelch Gate No. 24 16 Ch. DSP U/L Squelch Gate No. 25 16 Ch. DSP U/L Squelch Gate No.
5.5. Rack 1 Rear View A B C D E F G H I J Combiner Unit 60-228909 16 Ch. DSP U/L Squelch Gate No. 15 16 Ch. DSP U/L Squelch Gate No. 16 16 Ch. DSP U/L Squelch Gate No. 17 16 Ch. DSP U/L Squelch Gate No. 18 16 Ch. DSP U/L Squelch Gate No. 19 16 Ch. DSP U/L Squelch Gate No. 20 16 Ch. DSP U/L Squelch Gate No. 21 AC Circuit Breaker Krone terminal blocks for alarm outputs Axell Wireless Limited Technical Literature Document Number 60-228701HBK WMATA CRCS Redundant Antenna System General Overview Issue No.
5.6. Rack 1 elevations showing RF connections Uplink input from Rack 2 (Front) Sum of 16 Ch. DSP U/L Squelch Gates 1 - 7 Uplink input from Rack 2 (Rear) Sum of 16 Ch.
5.7. Rack 2 Front View A B C D E F G H I PSU Housing Shelf 96-300090 + Qty. 2, Part No. 96-300091 PSU Modules Combiner Unit 60-228906 16 Ch. DSP U/L Squelch Gate No. 1 16 Ch. DSP U/L Squelch Gate No. 2 16 Ch. DSP U/L Squelch Gate No. 3 16 Ch. DSP U/L Squelch Gate No. 4 16 Ch. DSP U/L Squelch Gate No. 5 16 Ch. DSP U/L Squelch Gate No. 6 16 Ch. DSP U/L Squelch Gate No. 7 Axell Wireless Limited Technical Literature Document Number 60-228701HBK WMATA CRCS Redundant Antenna System General Overview Issue No.
5.8. Rack 2 Rear View A B C D E F G H I J Combiner Unit 60-228908 16 Ch. DSP U/L Squelch Gate No. 8 16 Ch. DSP U/L Squelch Gate No. 9 16 Ch. DSP U/L Squelch Gate No. 10 16 Ch. DSP U/L Squelch Gate No. 11 16 Ch. DSP U/L Squelch Gate No. 12 16 Ch. DSP U/L Squelch Gate No. 13 16 Ch. DSP U/L Squelch Gate No. 14 AC Circuit Breaker Krone terminal blocks for alarm outputs Axell Wireless Limited Technical Literature Document Number 60-228701HBK WMATA CRCS Redundant Antenna System General Overview Issue No.
5.9. Rack 2 elevations showing RF connections Uplink output from Rack 2 (Front) Sum of 16 Ch. DSP U/L Squelch Gates 1 - 7 Uplink output from Rack 2 (Rear) Sum of 16 Ch. DSP U/L Squelch Gates 8 - 14 Alarm output Krone terminal blocks PSU Shelf 96-300090 + 2 x 96-300091 AC Circuit breaker Sum of 8-14 Sum of 1-7 06-001901 06-001901 U/L Inputs from CRCS donor unit Seg. 8-14 U/L Inputs from CRCS donor unit Seg. 1-7 7 U/L Combiner Unit (1-7) 60-228906 7 U/L Combiner Unit (8-14) 60-228908 16 Ch.
Axell Wireless Limited Technical Literature Document Number 60-228701HBK Pins 1 to 10 © AWL 2009 Date: 04/12/2009 15 Aerial House Asheridge Road Chesham Buckinghamshire HP5 2QD United Kingdom Telephone: +44 (0) 1494 777000 Facsimile: +44 (0) 1494 777002 E-Mail: info@axellwireless.com www.axellwireless.com 15 way “D” plug, alarm output from Dual Fibre Optic Unit 60-228703 1 Pins 1 to 8 9 RF Failover Switch Unit 60-228905 9 way “D” plug, alarm output from 1 60-228904 No. 24 60-228904 No.
Axell Wireless Limited Technical Literature Document Number 60-228701HBK © AWL 2009 Date: 04/12/2009 60-228904 No. 7 Aerial House Asheridge Road Chesham Buckinghamshire HP5 2QD United Kingdom Telephone: +44 (0) 1494 777000 Facsimile: +44 (0) 1494 777002 E-Mail: info@axellwireless.com www.axellwireless.com 60-228904 No. 1 60-228904 Nos. 2 to 6 60-228904 No. 9 60-228904 No. 10 60-228904 No. 14 -ve busbar Krone Terminal Block B 60-228904 Nos. 11 to 13 WMATA Gallery Place Station Rack 2, Part No.
5.11 Dual Fiber Optic Unit 60-228703 (Gallery Place Station) Dual Fiber Optic Unit 60-228703 is built into a 2U, 19” rack-mount case. The Primary Downlink optical signal from the Jackson Graham Building CRAS System enters the Dual Fiber Optic Unit via the SC/APC optical port 1 “RX” (annotated “A” in section 5.11.4.
5.11.1. Dual Fiber Optic Unit 60-228703 List of Major Sub-Components Component Part 20-001601 20-005401 20-005501 96-110013 96-200024 90-852420 94-100003 5.11.2. Part Description 12V Dual Relay Board Fiber Optic Transmitter Module Fiber Optic Receiver Module 3.15 A Fuse DC/DC Converter 20dB Directional Coupler Power Diode Qty Per Assembly 1 2 2 2 2 4 3 Dual Fiber Optic Unit 60-228703 Specification PARAMETER RF Downlink SPECIFICATION 489.5MHz to 491.0MHz 496.3MHz to 496.
5.11.3.
5.11.3.1. Dual Fiber Optic Unit 60-228703 Alarm Outputs 15 pin “D” panel plug “ALARM”, local alarm output to Krone terminal block “A” on rack (see section 5.5.
5.11.4. Dual Fiber Optic Unit 60-228703 Front View N F A TX E C D B MON -20dB TX 1 MON -20dB RX 1 TX 1 RX 1 MON -20dB TX 2 MON -20dB RX 2 TX 2 RX 2 Q O S R W CC BB 12V T3.15A 24V T3.
5.11.5. Dual Fiber Optic Unit 60-228703 Rear View A Axell Wireless Limited Technical Literature Document Number 60-228701HBK Earthing connection WMATA CRCS Redundant Antenna System General Overview Issue No.
5.12. RF Failover Switch Unit 60-228905 RF Failover Switch Unit 60-228905 is built into a 2U, 19” rack-mount case and receives both Primary (Jackson Graham Building) and Redundant (Carmen Turner Facility) Downlink signals from the Dual Fiber Optic Unit 60-228703; the RF level of the Primary Downlink is monitored by a power detector and if the signal falls below a preset threshold the unit automatically switches from the Primary to the standby Redundant path; the Uplink paths are switched at the same time.
The Automatic changeover of the transfer relay function can be overridden by selecting the Manual position of the switch labeled “AUTO / MANUAL” (annotated “S” in section 5.12.5.), the GREEN LED labeled “AUTO” (annotated “DD” in section 5.12.5.) is illuminated when in the Auto mode, the YELLOW LED labeled “MANUAL” (annotated “EE” in section 5.12.5.) will illuminate when the Manual mode is selected. In the Manual mode, the switch labeled “RX 1 / RX 2” (annotated “T” in section 5.12.5.
5.12.2.
Axell Wireless Limited Technical Literature Document Number 60-228701HBK © AWL 2009 Date: 01/12/2009 Aerial House Asheridge Road Chesham Buckinghamshire HP5 2QD United Kingdom Telephone: +44 (0) 1494 777000 Facsimile: +44 (0) 1494 777002 E-Mail: info@axellwireless.com www.axellwireless.
9 Rx2 is Active 0V +12 V 20-001601 0V +12 V NC NO COM NC NO COM 0V Path 2 Mon (Redundant D/L) 1 +12V 0V 0V 0V Auto / Manual 0V +12V +12V NC NO COM NC NO COM +24 V +24 V Manual On 20-001601 0V 20-001601 RF Failover Switch Unit 60-228905 Alarm Wiring Diagram NC NO COM NC NO COM Rx1 is Active +12V NC NO COM NC NO COM NC 0V Aerial House Asheridge Road Chesham Buckinghamshire HP5 2QD United Kingdom Telephone: +44 (0) 1494 777000 Facsimile: +44 (0) 1494 777002 E-Mail: info@axellw
5.12.4.1. RF Failover Switch Unit 60-228905 Alarm Outputs Front panel 9 pin “D” panel plug “ALARM”, local alarm output to Krone terminal block “A” on rack (see section 5.5.) Dry Contact Outputs (Closed = Normal / Open = Alarm) Summary output PSU modules Pins 1 & 2 Uplink path relay Pins 3, 4 & 5 Downlink path relay Pins 6, 7 & 8 Axell Wireless Limited Technical Literature Document Number 60-228701HBK Pin 6 Pin 1 Pin 9 Pin 5 WMATA CRCS Redundant Antenna System General Overview Issue No.
5.12.5.
5.12.6. RF Failover Switch Unit 60-228905 Rear View A Axell Wireless Limited Technical Literature Document Number 60-228701HBK Earthing connection WMATA CRCS Redundant Antenna System General Overview Issue No.
5.13. Combiner Unit 60-228906 Combiner Unit 60-228906 is built onto a 2U, 19” rack mount front panel and combines the Uplink output paths from the seven, 16 Ch. DSP U/L Squelch Gates 60-228904 mounted in the front of Rack 2 and passes the combined Uplink signal to Combiner Unit 60-228907 mounted in the front of Rack 1. 5.13.1.
5.13.2. Combiner Unit 60-228906 System Diagram Patch-panel U/L O/P to 16 Ch. DSP U/L Squelch Gate 1 U/L O/P to 16 Ch. DSP U/L Squelch Gate 2 U/L O/P to 16 Ch. DSP U/L Squelch Gate 3 U/L inputs from CRCS Donor Unit for 16 Ch. DSP U/L Squelch Gates 1-7 (connections on rear of front panel) U/L O/P to 16 Ch. DSP U/L Squelch Gate 4 U/L O/P to 16 Ch. DSP U/L Squelch Gate 5 U/L O/P to 16 Ch. DSP U/L Squelch Gate 6 U/L O/P to 16 Ch. DSP U/L Squelch Gate 7 93-930008 U/L I/P from 16 Ch.
Danger Combiner Unit 60-228906 Front and Rear Views A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Beryllium oxide 5.13.3. Patch-panel for U/L I/Ps from CRCS donor unit and O/Ps to 16 Ch. DSP U/L Squelch Gates 1 to 7 Uplink input for 16 Ch. DSP U/L Squelch Gate No. 1 from CRCS donor unit Uplink input for 16 Ch. DSP U/L Squelch Gate No. 2 from CRCS donor unit Uplink input for 16 Ch. DSP U/L Squelch Gate No. 3 from CRCS donor unit Uplink input for 16 Ch. DSP U/L Squelch Gate No.
5.14. Combiner Unit 60-228908 Combiner Unit 60-228908 is built onto a 2U, 19” rack mount front panel and combines the Uplink output paths from the seven, 16 Ch. DSP U/L Squelch Gates 60-228904 mounted in the rear of Rack 2 and passes the combined Uplink signal to Combiner Unit 60-228907 mounted in the front of Rack 1. 5.14.1.
5.14.2. Combiner Unit 60-228908 System Diagram Patch-panel U/L O/P to 16 Ch. DSP U/L Squelch Gate 8 U/L O/P to 16 Ch. DSP U/L Squelch Gate 9 U/L O/P to 16 Ch. DSP U/L Squelch Gate 10 U/L inputs from CRCS Donor Unit for 16 Ch. DSP U/L Squelch Gates 8-14 (connections on rear of front panel) U/L O/P to 16 Ch. DSP U/L Squelch Gate 11 U/L O/P to 16 Ch. DSP U/L Squelch Gate 12 U/L O/P to 16 Ch. DSP U/L Squelch Gate 13 U/L O/P to 16 Ch. DSP U/L Squelch Gate 14 93-930008 U/L I/P from 16 Ch.
Danger Combiner Unit 60-228908 Front and Rear Views A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Beryllium oxide 5.14.3. Patch-panel for U/L I/Ps from CRCS donor unit and O/Ps to 16 Ch. DSP U/L Squelch Gates 8 to 14 Uplink input for 16 Ch. DSP U/L Squelch Gate No. 8 from CRCS donor unit Uplink input for 16 Ch. DSP U/L Squelch Gate No. 9 from CRCS donor unit Uplink input for 16 Ch. DSP U/L Squelch Gate No. 10 from CRCS donor unit Uplink input for 16 Ch. DSP U/L Squelch Gate No.
5.15. Combiner Unit 60-228909 Combiner Unit 60-228909 is built onto a 2U, 19” rack mount front panel and combines the Uplink output paths from the seven, 16 Ch. DSP U/L Squelch Gates 60-228904 mounted in the rear of Rack 1 and passes the combined Uplink signal to Combiner Unit 60-228907 mounted in the front of Rack 1. 5.15.1.
5.15.2. Combiner Unit 60-228909 System Diagram Patch-panel U/L O/P to 16 Ch. DSP U/L Squelch Gate 8 U/L O/P to 16 Ch. DSP U/L Squelch Gate 9 U/L O/P to 16 Ch. DSP U/L Squelch Gate 10 U/L inputs from CRCS Donor Unit for 16 Ch. DSP U/L Squelch Gates 8-14 (connections on rear of front panel) U/L O/P to 16 Ch. DSP U/L Squelch Gate 11 U/L O/P to 16 Ch. DSP U/L Squelch Gate 12 U/L O/P to 16 Ch. DSP U/L Squelch Gate 13 U/L O/P to 16 Ch. DSP U/L Squelch Gate 14 93-930008 U/L I/P from 16 Ch.
Danger Combiner Unit 60-228909 Front and Rear Views A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Beryllium oxide 5.15.3. Patch-panel for U/L I/Ps from CRCS donor unit and O/Ps to 16 Ch. DSP U/L Squelch Gates 15 to 21 Uplink input for 16 Ch. DSP U/L Squelch Gate No. 15 from CRCS donor unit Uplink input for 16 Ch. DSP U/L Squelch Gate No. 16 from CRCS donor unit Uplink input for 16 Ch. DSP U/L Squelch Gate No. 17 from CRCS donor unit Uplink input for 16 Ch. DSP U/L Squelch Gate No.
5.16. Combiner Unit 60-228907 Combiner Unit 60-228907 is built onto a 2U, 19” rack mount front panel and combines the Uplink output paths from Combiner units 60-228906. 60-228908 & 60-228909 with the Uplink paths from the five, 16 Ch. DSP U/L Squelch Gates 60-228904 mounted in the front of Rack 1 and passes the combined Uplink signal to RF Failover Switch Unit 60-228905. 5.16.1.
5.16.2. Combiner Unit 60-228907 System Diagram Patch-panel U/L O/P to 16 Ch. DSP U/L Squelch Gate 22 U/L O/P to 16 Ch. DSP U/L Squelch Gate 23 U/L inputs from CRCS Donor Unit for 16 Ch. DSP U/L Squelch Gates 22-26 (connections on rear of front panel) U/L O/P to 16 Ch. DSP U/L Squelch Gate 24 U/L O/P to 16 Ch. DSP U/L Squelch Gate 25 U/L O/P to 16 Ch. DSP U/L Squelch Gate 26 3 x 93-930008 RG223 jump lead, connectors on front panel U/L I/P from 16 Ch. DSP U/L Squelch Gate 26 U/L I/P from 16 Ch.
Danger Combiner Unit 60-228907 Front and Rear Views A B C D E F G H I J K L M N O P Q R S T U V W X Y Z Beryllium oxide 5.16.3. Patch-panel for U/L I/Ps from CRCS donor unit and O/Ps to 16 Ch. DSP U/L Squelch Gates 22 to 26 Uplink input for 16 Ch. DSP U/L Squelch Gate No. 22 from CRCS donor unit Uplink input for 16 Ch. DSP U/L Squelch Gate No. 23 from CRCS donor unit Uplink input for 16 Ch. DSP U/L Squelch Gate No. 24 from CRCS donor unit Uplink input for 16 Ch. DSP U/L Squelch Gate No.
5.17. 16 Ch. DSP U/L Squelch Gate 60-228904 16 Ch. DSP U/L Squelch Gate 60-228904 is built onto a 4U, 19” rack-mount case. There are 26 DSP U/L Squelch Gate units in the Gallery Place System each one receives an Uplink input from the existing CRCS donor unit. The purpose of the Squelch gate is to selectively filter the required frequencies from the input broadband noise and intermodulation and to incorporate a digit squelch to the signal.
5.17.1. 16 Ch. DSP U/L Squelch Gate 60-228904 List of Major Sub-Components Component Part 05-002603 19-002202 96-110009 E921030 H561003 J1161030 J1421001 R031002 Part Description 3dB Splitter/Combiner Interconnection Assembly 6.3A Fuse UHF SDR Module (489.25-500.
5.17.2. 16 Ch. DSP U/L Squelch Gate 60-228904 Specification SPECIFICATION PARAMETER Uplink Frequency Range No. of Channels Maximum Gain Passband ripple ALC Setting All channels ON ALC Dynamic Range Switched attenuator In Band Spurious Noise (30kHz B/W) Squelch Level Squelch Level Squelch Level General Supply Voltage Current consumption Alarm output Summary volts free dry contact output (Closed = Normal / Open = Alarm) (1) 492.5MHz to 494.0MHz 499.3MHz to 499.7MHz 16 (1) +43 ±1dB ≤ ±1.5 dB -7.
5.17.3. 16 Ch. DSP U/L Squelch Gate 60-228904 System Diagram E921030 TETRA SDR MODULE 489,25 - 500,50 MHz 8 CHANNEL DSP 05-002603 UPLINK RF OUT 05-002603 UPLINK RF IN 8 CHANNEL DSP J142001 +15 VDC +12 VDC +6.45 VDC 19-002202 96-110001 6.3A FUSE Alarm PC Control System Monitoring Point Date: 10/12/2009 © AWL 2009 Aerial House Asheridge Road Chesham Buckinghamshire HP5 2QD United Kingdom Telephone: +44 (0) 1494 777000 Facsimile: +44 (0) 1494 777002 E-Mail: info@axellwireless.com www.axellwireless.
5.17.3.1. 16 Ch. DSP U/L Squelch Gate 60-228904 Alarm Output Axell Wireless Limited Technical Literature Document Number 60-228701HBK WMATA CRCS Redundant Antenna System General Overview Issue No.
5.17.4. 16 Ch. DSP U/L Squelch Gate 60-228904 Front View Status Modem Status Modem Power Login LMT Port A B C D E F G H I N type port “A”, Uplink input from Combiner Unit 60-228907 N type port “B”, Uplink output to Combiner Unit 60-228907 24V DC input from PSU module 96-300091 in PSU shelf 96-300090 6.
5.17.5. 16 Ch. DSP U/L Squelch Gate 60-228904 Rear View A Axell Wireless Limited Technical Literature Document Number 60-228701HBK Earthing connection WMATA CRCS Redundant Antenna System General Overview Issue No.
5.18. PSU Housing Shelf 96-300090 These are 1U high, 19” Rack Mount shelves each housing two, 960W, fan cooled, AC mains driven PSU modules (96-300091) the outputs of which are combined to provide a 24V DC supply to the other chassis in the system. The DC leads connected to the output terminals (annotated “B” and “C” in section 5.18.2.) are connected to two pairs of busbars, one on either side of each rack.
5.18.2. PSU Module Chassis 96-300090 Rear View A B C D E 5.18.3. AC inputs 24V DC terminal (connects to rack 24V busbar) 0V DC terminal (connects to rack 0V busbar) Alarm output to Krone terminal block on rack Earthing connector PSU Module Chassis 96-300090 Alarm Wiring 25 pin “D” panel socket, local alarm/control output to Krone terminal blocks on rack (see section 5.
5.18.4. DC Connector Details 5.18.4.1. DC Inlet Free Socket These are the free sockets that are connected to the rack busbars A B C D E 5.18.4.2.
Axell Wireless Limited Technical Literature Document Number 60-228701HBK WMATA CRCS Redundant Antenna System General Overview Issue No.
Appendix A A.1. Glossary of Terms used in this document Repeater or Cell Enhancer Band Selective Repeater Channel Selective Repeater AC AGC BDA BTS B/W C/NR CRCS CRAS DAS DC Downlink (D/L) DSP F/O GND ID I/P LCX LED LNA LPA Mobile(s) MOU MTBF N/A N/C (of Relays) N/O (of Relays) OFR OIP3 O/P P1dB PA RF RHNC RSA RX SDR S/N TX Uplink (U/L) VSWR Date Format A Radio Frequency (RF) amplifier which can simultaneously amplify and re-broadcast Mobile Station (MS) and Base Transceiver Station (BTS) signals.
A.2. Key to Drawing Symbols used in this document Axell Wireless Limited Technical Literature Document Number 60-228701HBK WMATA CRCS Redundant Antenna System General Overview Issue No.
A.3. EC Declaration of Conformity In accordance with BS EN ISO/IEC 17050-1&-2:2004 Axell Wireless Limited Aerial House Asheridge Road Chesham Buckinghamshire HP5 2QD United Kingdom Declares, under our sole responsibility that the following product: Product Part Nos.
A.4. Waste Electrical and Electronic Equipment (WEEE) Notice The Waste Electrical and Electronic Equipment (WEEE) Directive became law in most EU countries during 2005. The directive applies to the disposal of waste electrical and electronic equipment within the member states of the European Union.
A.5. Document Amendment Record Issue No. 1 Date 18/11/2009 Incorporated by AJS/GD 2 15/02/2010 AJS 3 28/05/2010 AJS Axell Wireless Limited Technical Literature Document Number 60-228701HBK Section Amended Reason for new issue Draft Customer changes CRCS & CRAS Reformat to US Letter size WMATA CRCS Redundant Antenna System General Overview Issue No.