AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 605 'LJLWDO 0XOWL &KDQQHO ,3 1(0$ %DQG 6HOHFWLYH 5HSHDWHU 352'8&7 '(6&5,37,21 $1' 86(5¶6 0$18$/ IRU $;(// ' 0%5 36 1)3$ 5(3($7(5 80&' 5HY D-MBR 3007-3008 PS NFPA
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL &RS\ULJKW $[HOO :LUHOHVV /WG $OO ULJKWV UHVHUYHG 1R SDUW RI WKLV GRFXPHQW PD\ EH FRSLHG GLVWULEXWHG WUDQVPLWWHG WUDQVFULEHG VWRUHG LQ D UHWULHYDO V\VWHP RU WUDQVODWHG LQWR DQ\ KXPDQ RU FRPSXWHU ODQJXDJH ZLWKRXW WKH SULRU ZULWWHQ SHUPLVVLRQ RI $[HOO :LUHOHVV /WG 7KH PDQXIDFWXUHU KDV PDGH HYHU\ HIIRUW WR HQVXUH WKDW WKH LQVWUXFWLRQV FRQWDLQHG LQ WKLV GRFXPHQW DUH DGHTXDWH DQG IUHH RI HUURUV DQG RPLVVLRQV 7KH PDQX
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL $ERXW 7KLV 0DQXDO 7KLV 3URGXFW 0DQXDO SURYLGHV WKH IROORZLQJ LQIRUPDWLRQ • 'HVFULSWLRQ RI WKH 5HSHDWHU • 3URFHGXUHV IRU VHWXS FRQILJXUDWLRQ DQG FKHFNLQJ WKH SURSHU RSHUDWLRQ RI WKH 5HSHDWHU • 0DLQWHQDQFH DQG WURXEOHVKRRWLQJ SURFHGXUHV )RU ZKRP LW LV ,QWHQGHG 7KLV 3URGXFW 0DQXDO LV LQWHQGHG IRU H[SHULHQFHG WHFKQLFLDQV DQG HQJLQHHUV ,W LV DVVXPHG WKDW WKH FXVWRPHUV LQVWDOOLQJ RSHUDWLQJ DQG PDLQWDLQLQJ $[H
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL &RPSOLDQFH ZLWK )&& Note the following: This repeater can be operated as Part 90 Class A repeater. )&& 3DUW :DUQLQJ 6WDWHPHQW WARNING: This is NOT a CONSUMER device. It is designed for installation by FCC LICENCEES and QUALIFIED INSTALLERS. You must have an FCC LICENCE or express consent of an FCC Licensee to operate this device. This is a Class B signal booster.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL )&& 5) ([SRVXUH /LPLWV 7KLV XQLW FRPSOLHV ZLWK )&& 5) H[SRVXUH OLPLWV IRU DQ XQFRQWUROOHG HQYLURQPHQW 7KLV HTXLSPHQW FDQ RQO\ EH LQVWDOOHG LQ LQ EXLOGLQJ DSSOLFDWLRQV GULYLQJ SDVVLYH RU DFWLYH '$6 V\VWHPV $OO DQWHQQDV PXVW EH RSHUDWHG DW D PLQLPXP GLVWDQFH RI FP EHWZHHQ WKH UDGLDWRU DQG DQ\ SHUVRQ¶V ERG\ $QWHQQD ,QVWDOODWLRQ ,QVWDOODWLRQ RI DQ DQWHQQD PXVW FRPSO\ ZLWK WKH )&& 5) H[SRVXUH UH
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL &RPSOLDQFH ZLWK )&& GHSOR\PHQW UXOH UHJDUGLQJ WKH UDGLDWLRQ RI QRLVH *RRG HQJLQHHULQJ SUDFWLFH PXVW EH XVHG LQ UHJDUG WR WKH VLJQDO ERRVWHU¶V QRLVH UDGLDWLRQ 7KXV WKH JDLQ RI WKH VLJQDO ERRVWHU VKRXOG EH VHW VR WKDW WKH (53 RI WKH RXWSXW QRLVH IURP WKH VLJQDO ERRVWHU VKRXOG QRW H[FHHG WKH OHYHO RI G%P LQ N+] PHDVXUHPHQW EDQGZLGWK ,Q WKH HYHQW WKDW WKH QRLVH OHYHO PHDVXUHG H[FHHGV WKH DIRUHPHQWLRQHG YDOXH WKH VLJQD
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 7KLV HTXLSPHQW FRPSOLHV ZLWK ,& 566 UDGLDWLRQ H[SRVXUH OLPLWV VHW IRUWK IRU DQ XQFRQWUROOHG HQYLURQPHQW 7KLV HTXLSPHQW VKRXOG EH LQVWDOOHG DQG RSHUDWHG ZLWK PLQLPXP GLVWDQFH RI FP EHWZHHQ WKH DQWHQQD DQG \RXU ERG\ &RQIRUPpPHQW j OD UpJOHPHQWDWLRQ G ,QGXVWULH &DQDGD OH SUpVHQW pPHWWHXU UDGLR SHXW IRQFWLRQQHU DYHF XQH DQWHQQH G XQ W\SH HW G XQ JDLQ PD[LPDO RX LQIpULHXU DSSURXYp SRXU O pPHWWHXU
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL *HQHUDO 6DIHW\ :DUQLQJV &RQFHUQLQJ 8VH RI 7KLV 6\VWHP $OZD\V REVHUYH VWDQGDUG VDIHW\ SUHFDXWLRQV GXULQJ LQVWDOODWLRQ RSHUDWLRQ DQG PDLQWHQDQFH RI WKLV SURGXFW &DXWLRQ ODEHOV 'DQJHU (OHFWULFDO 6KRFN &DXWLRQ 6DIHW\ WR SHUVRQQHO &DXWLRQ 6DIHW\ WR HTXLSPHQW 7KURXJKRXW WKLV PDQXDO WKHUH DUH &DXWLRQ ZDUQLQJV &DXWLRQ FDOOV DWWHQWLRQ WR D SURFHGXUH RU SUDFWLFH ZKLFK LI LJQRUHG PD\ UHVXOW L
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 7DEOH RI &RQWHQWV 1 Introduction .................................................................................................................................. 1 1.1 Main Features ........................................................................................................................ 2 1.2 Repeater Model .....................................................................................................
AXELL D-MBR 3007-3008-PS NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 4 Initial Setup and Commissioning ............................................................................................. 26 4.1 Open a Session to the Repeater .......................................................................................... 26 4.1.1 Connect the Repeater to the Computer .................................................................. 26 4.1.2 Configure the Computer Network Parameters ...............
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 1 Introduction ' 0%5 36 1)3$ 'LJLWDO 0XOWL %DQG 5HSHDWHU IRU 3XEOLF 6DIHW\ LV D KLJK SRZHU GLJLWDO PXOWL FKDQQHO VLJQDO ERRVWHU '&6% ,W IHDWXUHV DQ DUUD\ RI XS WR '63 EDVHG VRIWZDUH FRQWUROOHG YDULDEOH EDQGZLGWK ILOWHUV WKDW DUH XVHU SURJUDPPDEOH DFURVV WKH DQG 0+] EDQGV ' 0%5 36 1)3$ VXSSRUWV DOO SXEOLF VDIHW\ WHFKQRORJLHV )RU HDFK ILOWHU WKH XVHU FDQ VSHFLI\ W
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 1.1 Main Features • &ODVV $ RU % VLJQDO ERRVWHU EDVHG RQ ILOWHU VHWWLQJ IRU 605 DQG SXEOLF VDIHW\ QHWZRUNV • 6XSSRUWV $3&2 SKDVH DQG IRU SXEOLF VDIHW\ QHWZRUNV • 1)3$ &KDSWHU DQG ,)& &RPSOLDQW • 6XSSRUW RI 0+] ' EORFN IRU /7( QHWZRUN • 605 0+] DQG 0+] EDQGV LQ D VLQJOH HQFORVXUH • 5) *DLQ 8S WR G% *DLQ • 6$/& 6PDUW $/& PHFKDQLVP WR SURWHFW WKH GLJLWDO VLJQDO ERRVWHU
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 1.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 1.4 6PDUW $/& )XQFWLRQ 7KH 5HSHDWHU¶V SRZHU DPSOLILHU LQFOXGHV SRZHU PRQLWRULQJ FLUFXLWV ZLWK $XWRPDWLF /HYHO &RQWURO $/& WKDW SUHYHQWV H[FHVVLYH RXWSXW SRZHU ZKLOH PDLQWDLQLQJ WKH SRZHU DPSOLILHU OLQHDULW\ 7KH 6PDUW $XWRPDWLF /HYHO &RQWURO 6PDUW $/& LV DQ LQQRYDWLYH DOJRULWKP IRU DXWRPDWLF 5HSHDWHU JDLQ DGMXVWPHQW &RPELQHG ZLWK DGYDQFHG FRQWURO DOJRULWKPV 6 $/& LV FDSDEOH RI OHDUQLQJ WKH WUDIILF ORDG FKDUDFWHULV
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 1.6 1DYLJDWLQJ WKH :HE *8, $SSOLFDWLRQ 7KLV VHFWLRQ GHVFULEHV KRZ WR QDYLJDWH WKH :HE 0DQDJHPHQW DSSOLFDWLRQ 7KH :HE $FFHVV LQWHUIDFH SURYLGHV WKH IROORZLQJ JURXSV RI RSWLRQV • 7RSRORJ\ 7UHH ± SURYLGHV DFFHVV WR XQLW OHYHO DQG EDQG OHYHO RSWLRQV • 7DEV ± %DQG DQG XQLW &08 OHYHO RSWLRQV FRUUHVSRQGLQJ WR WKH VHOHFWHG WUHH LWHP • 2SHUDWLRQ EXWWRQV ± FRQWURO DQG PDQDJHPHQW RSWLRQV 7KH RSHUDWLRQ EXWWRQV DW WKH WRS DUH FRPPRQ WR
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 1.6.2 Operation Buttons 7KH IROORZLQJ 2SHUDWLRQ EXWWRQV DUH DYDLODEOH ,WHP 'HVFULSWLRQ 9DOXHV 6HQG &OLFN WR VDYH FKDQJHV ± EHIRUH H[LWLQJ WKH VFUHHQ RWKHUZLVH FKDQJHV ZLOO QRW EH VDYHG 5HIUHVK &OLFN WR UHIUHVK WKH FXUUHQW VFUHHQ DQG XSGDWH WKH GLVSOD\HG GDWD &08 5HVHW &OLFN WR UHVHW WKH :HE $FFHVV DSSOLFDWLRQ 8VH LQ FDVH RI IDLOXUH RU GLVSOD\ SUREOHPV 'DWH DQG 7LPH 8VHG WR VHW WKH 5HSHDWHU FORFN $
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 1.6.4 CMU Pane and Tabs &08 7RSRORJ\ 7UHH PHQX LWHPV ,WHP 'HVFULSWLRQ 9DOXHV $[HOO &08 $ODUPV 6KRZV DQ\ JHQHUDWHG H[WHUQDO DODUPV $[HOO &08 ,QIR 6KRZV 5HSHDWHU OHYHO LQIRUPDWLRQ VXFK DV 6: DQG +: YHUVLRQV DQG LGHQWLILFDWLRQ QXPEHU ,Q DGGLWLRQ HQDEOHV VHWWLQJ PLQLPXP DODUP OHYHOV 6HH VHFWLRQ &RPPXQLFDWLRQ &RQILJXUDWLRQ 8VHG WR VHW FRPPXQLFDWLRQ SDUDPHWHUV 6HH VHFWLRQ $ODUPV /RJ /RJ RI SDVW DQG FXU
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 2 Antenna Installation Requirements 7KLV FKDSWHU SURYLGHV LQIRUPDWLRQ RQ WKH VSHFLILFDWLRQV RI WKH GRQRU DQG VHUYLFH DQWHQQDV VXLWDEOH IRU RSHUDWLRQ ZLWK WKLV UHSHDWHU RQ WKH LQVWDOODWLRQ UHTXLUHPHQWV RI WKH DQWHQQDV DQG RQ WKH 5HSHDWHU LQVWDOODWLRQ VLWH DQG FDEOH UHTXLUHPHQWV $77(17,21 7KH %65 PRGHOV GHVFULEHG LQ WKLV PDQXDO KDYH EHHQ DSSURYHG E\ ,QGXVWU\ &DQDGD WR RSHUDWH ZLWK WKH DQWHQQD W\SHV OLVWHG EHORZ ZLWK
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 2.2 Service Antenna Requirements The Service antenna type depends on whether the Repeater is installed indoors or outdoors. WARNINGS!!! • 7KH LQVWDOOHU LV KHOG DFFRXQWDEOH IRU LPSOHPHQWLQJ WKH UXOHV UHTXLUHG IRU GHSOR\PHQW • *RRG HQJLQHHULQJ SUDFWLFH PXVW EH XVHG WR DYRLG LQWHUIHUHQFH • 2XWSXW SRZHU VKRXOG EH UHGXFHG WR VROYH DQ\ ,0' LQWHUIHUHQFH LVVXHV 2.2.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 2.2.2.2 Installation Criteria Installation requirements: • $Q LQGRRU DQWHQQD VKRXOG EH LQVWDOOHG DW D FRQYHQLHQW ORFDWLRQ ,W VKRXOG EH IUHH RI PHWDOOLF REVWUXFWLRQ • ,QVWDOO WKH 6HUYLFH $QWHQQD DW WKH GHVLJQDWHG KHLJKW DQG WXQH LW URXJKO\ WRZDUG WKH 6HUYLFH FRYHUDJH DUHD • ,QVWDOODWLRQ RI WKLV DQWHQQD PXVW SURYLGH D PLQLPXP VHSDUDWLRQ GLVWDQFH RI FP IURP DQ\ SHUVRQQHO ZLWKLQ WKH DUHD 2.2.
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 2.2.3.2 Vertical Separation Configuration 7KH 9HUWLFDO 6HSDUDWLRQ FRQILJXUDWLRQ LV UHFRPPHQGHG LQ FDVHV ZKHUH WKH %76 LV UHODWLYHO\ IDU DQG WKH VHUYLFH FRYHUDJH DUHD LV UHODWLYHO\ VPDOO ,Q 9HUWLFDO 6HSDUDWLRQ FRQILJXUDWLRQ WKH 'RQRU DQWHQQD FDQ EH LQVWDOOHG HLWKHU DERYH RU EHORZ WKH 6HUYLFH DQWHQQD RQ D &20021 WRZHU ,W LV UHTXLUHG WR VHW WKH GLVWDQFH EHWZHHQ WKHP WR DFKLHYH PD[LPXP LVRODWLRQ 7KH ILJXUHV EHORZ LOOXVWUDWH WKH LQVWD
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 2.2.3.3 Horizontal Separation Configuration ,Q WKH +RUL]RQWDO 6HSDUDWLRQ FRQILJXUDWLRQ WKH 'RQRU DQG 6HUYLFH DQWHQQDV DUH LQVWDOOHG RQ WZR VHSDUDWH WRZHUV DW DSSUR[LPDWHO\ WKH VDPH KHLJKW 7KH WRZHUV FDQ EH HLWKHU RQ WKH VDPH VLGH RI WKH EXLOGLQJ RU RQ GLIIHUHQW VLGHV RI WKH EXLOGLQJ DV VKRZQ EHORZ 12 Figure 2-3. Donor and Service Antennas Figure 2-4.
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 3 Installing the Repeater 3.1 Repeater Pre-Installation Requirements 3.1.1 Safety Guidelines %HIRUH LQVWDOOLQJ WKH 5HSHDWHU UHYLHZ WKH IROORZLQJ VDIHW\ LQIRUPDWLRQ • )ROORZ DOO ORFDO VDIHW\ UHJXODWLRQV ZKHQ LQVWDOOLQJ WKH 5HSHDWHU • 2QO\ TXDOLILHG SHUVRQQHO DUH DXWKRUL]HG WR LQVWDOO DQG PDLQWDLQ WKH 5HSHDWHU • *URXQG WKH 5HSHDWHU ZLWK WKH JURXQGLQJ EROW ORFDWHG RQ WKH H[WHUQDO ORZHU VLGH RI WKH 5HSHDWHU • 'R QRW XVH WK
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL • 9HULI\ WKDW WKHUH LV D PLQLPXP RI D FP ´ UDGLXV RI VSDFH DURXQG WKH 5HSHDWHU DQG PHWHU LQ GHSWK IW LQ RUGHU WR DOORZ WKH XQLW GRRU WR VZLQJ FRPSOHWHO\ RSHQ HQDEOLQJ HDV\ DFFHVV WR WKH 5HSHDWHU IRU PDLQWHQDQFH DQG RQ VLWH LQVSHFWLRQ • )ROORZ (OHFWUR 6WDWLF 'LVFKDUJH (6' SUHFDXWLRQV • ,QVWDOO WKH 5HSHDWHU FORVH WR WKH VHUYLFH DUHD WR PRQLWRU WKH RXWSXW SRZHU DQG QRLVH ILJXUH • 9HULI\ WKDW DPELHQW WH
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 3.3 8QSDFNLQJ 8SRQ UHFHLYLQJ WKH ' 0%5 XQLW SHUIRUP WKH IROORZLQJ • ([DPLQH WKH VKLSSLQJ FRQWDLQHU IRU GDPDJH EHIRUH XQSDFNLQJ WKH XQLW • 3HUIRUP D YLVXDO LQVSHFWLRQ WR UHYHDO DQ\ SK\VLFDO GDPDJH WR WKH HTXLSPHQW • 9HULI\ WKDW DOO RI WKH HTXLSPHQW OLVWHG EHORZ LV LQFOXGHG VHH DOVR WKH IROORZLQJ SDJH 2WKHUZLVH FRQWDFW $[HOO :LUHOHVV ' 0%5 36 1)3$ (WKHUQHW FDEOH &' ZLWK GRFXPHQWDWLRQV 0RXQWLQJ %UDFNHW Z
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 3.4 0RXQWLQJ WKH ' 0%5 3.4.1 Pre-Mounting Procedure &KRRVH WKH ORFDWLRQ RI WKH 5HSHDWHU RQ WKH ZDOO DFFRUGLQJ WR WKH IROORZLQJ FULWHULD • 7KH ORFDWLRQ VKRXOG EH DW QRUPDO H\H OHYHO KHLJKW DERYH JURXQG • %H VXUH WR DOORZ HDV\ DFFHVV WR WKH 5HSHDWHU IRU PDLQWHQDQFH DQG RQ VLWH LQVSHFWLRQ 3ODFH WKH 0RXQWLQJ %UDFNHW DJDLQVW WKH ZDOO DQG PDUN WKH IRXU KROHV WR EH GULOOHG DW WKH H[WUHPH IRXU FRUQHUV RI WKH EUDFNHW
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 3.4.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 3.4.4 Mounting the Repeater 3LFN XS WKH 5HSHDWHU DQG DOLJQ WKH 5HSHDWHUV¶ IRXU LQVWDOODWLRQ KROHV ZLWK WKH 0RXQWLQJ %UDFNHWV¶ SLQV 6OLGH WKH EUDFNHWV SLQV WKURXJK WKH 5HSHDWHU KROHV XQWLO WKH XSSHU VLGH LV ORFNHG ZLWK WKH LQVWDOODWLRQ KHDG QXWV DW WKH WRS RI WKH EUDFNHW 6HH )LJXUH 5HOHDVH WKH IRXU FDSWLYH VFUHZV ORFNLQJ WKH 5HSHDWHU FRYHU NOTE: The NFPA unit is colored RED. Figure 3-4.
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL ,QVHUW WKH FODPSV LQFOXGLQJ WKH VFUHZV LQ WR WKH XSSHU RULILFHV OHDGLQJ LQVLGH WKH 5HSHDWHU Figure 3-6.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 3.5 *URXQGLQJ NOTE: Refer to section 3.1.5 for the grounding requirements. WARNINGS!!! Do not use the grounding bolt to connect external devices. To ground repeater &RQQHFW PDLQ JURXQG WR 5HSHDWHU JURXQGLQJ OXJ DW WKH VLGH RI WKH UHSHDWHU NOTE: The NFPA unit is colored RED. Grounding lug Figure 3-8. Grounding Lug Location 3.
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL To measure the isolation, proceed as follows: ,QMHFW D NQRZQ VLJQDO IURP D VLJQDO JHQHUDWRU LQWR RQH DQWHQQD SUHIHUDEO\ WKH 'RQRU DQWHQQD 0HDVXUH WKH FRXSOHG RXWSXW IURP WKH 6HUYLFH DQWHQQD XVLQJ WKH 6SHFWUXP DQDO\]HU DQG /1$ LI DSSOLFDEOH 3HUIRUP WKLV SURFHGXUH DFURVV WKH IUHTXHQF\ UDQJH RI ERWK WKH 8SOLQN DQG 'RZQOLQN EDQGV 5HJLVWHU WKH ORZHU UHVXOW IRU V\VWHP RSHUDWLRQ 3.6.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 3.8 3RZHULQJ 8S WKH ' 0%5 NOTE: The Repeater is connected to power via the assembled AC/DC power supply. WARNING! This equipment can either be installed indoors or outdoors. When installing outdoors - Wet conditions increase the potential for electric shock when installing or using electrically powered equipment.
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 3.8.2 D-MBR-PS NFPA Power Connection NOTE: D-MBR 3007-3008-PS NFPA Repeaters may be (if required) connected to the power source via a UPS. /RFDWH WKH $& SRZHU RXWOHW ZLWK DW OHDVW D $ VORZ EORZ IXVH &RQQHFW D 9$& SRZHU VRXUFH WR WKH 836 DQG WKH 836 WR WKH $& '& FRQYHUWHU SRZHU FDEOH
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 3.9.1 Alarm Connector Pinout (DFK DODUP VWDWXV LV UHFRJQL]HG E\ D VHSDUDWH ZLUH SDLU ZKHUH WKH FRORUHG ZLUHV DUH LQWHUQDOO\ FRQQHFWHG ZLWK D . RKP UHVLVWRU VHUYHV DV D SXOO XS UHVLVWRU WR 9 7KH IROORZLQJ ILJXUH VKRZV WKH $ODUP FRQQHFWRU SLQRXW Figure 3-11. Alarm Connector Pinout 3LQ 1R 6LJQDO 1DPH :LUH &RORU ([WHUQDO $ODUP %ODFN ([WHUQDO $ODUP 'U\ &RQWDFW 96:5 $ODUP 1RUPD
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 3.9.3 Summary Alarms Trigger Criteria 7KH 6XPPDU\ DODUP SLQV DQG LV WULJJHUHG XQGHU RQH RU PRUH RI WKH IROORZLQJ • 3$ &XUUHQW IURP )) • 7HPSHUDWXUH +LJK • %XLOW LQ 7HVW 7KH VXPPDU\ DODUP SLQV UHVSRQG DV IROORZV 67$786 ([WHUQDO $ODUP RQ 86(5 FRQQHFWRU 5(68/7 3RZHU 2)) &RQWDFWV 23(1 $/$50 3RZHU 21 &RQWDFWV &/26( 12 $/$50 6XPPDU\ $/$50 $FWLYH &RQWDFWV 23(1 $/$50 3.9.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 4 Initial Setup and Commissioning 7KLV VHFWLRQ GHVFULEHV WKH VHWXS SURFHGXUHV IRU WKH ' 0%5 36 5HSHDWHU 7KH LQLWLDO VHWXS SURFHGXUH LV SHUIRUPHG WKURXJK D :HE FRQQHFWLRQ IURP D FRPSXWHU RQ WKH VDPH VXEQHW XVLQJ D FURVV RYHU (WKHUQHW FDEOH VXSSOLHG The setup procedure consists of the following steps: 2SHQ D ORFDO :HE VHVVLRQ WR WKH 5HSHDWHU WKLV UHTXLUHV FRQILJXULQJ WKH FRPPXQLFDWLRQ SDUDPHWHUV RI WKH FRPSXWHU XVHG
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL To configure the computer’s network parameters: &OLFN WKH 6WDUW PHQX DQG FKRRVH &RQWURO 3DQHO ,Q WKH &RQWURO 3DQHO FOLFN 1HWZRUN DQG ,QWHUQHW &RQQHFWLRQV &OLFN 1HWZRUN DQG 6KDULQJ &HQWHU DQG WKHQ FOLFN /RFDO $UHD &RQQHFWLRQ 7KH /RFDO $UHD &RQQHFWLRQV 6WDWXV GLDORJ DSSHDUV ZLWK WKH *HQHUDO WDE GLVSOD\HG E\ GHIDXOW &OLFN WKH 3URSHUWLHV EXWWRQ LQ WKH GLVSOD\HG /RFDO $UHD &RQQHFWLRQ 6WDWXV GLDORJ ,Q WKH ,WHP
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL $VVLJQ \RXU FRPSXWHU DQ ,3 DGGUHVV LQ WKH VDPH VXEQHW LQ RUGHU WR FRPPXQLFDWH ZLWK WKH XQLW • ,Q WKH ,3 DGGUHVV DUHD • (QWHU WKH ,3 DGGUHVV [ ZKHUH µ[¶ FDQ EH DQ\ QXPEHU EHWZHHQ DQG LQFOXVLYH )RU H[DPSOH • 'HILQH WKH VXEQHW PDVN DV VKRZQ o 28 &OLFN 2. 7KH FRPSXWHU FRPPXQLFDWLRQ SDUDPHWHUV DUH QRZ GHILQHG DQG \RX FDQ RSHQ D VHVVLRQ WR WKH 5HSHDWHU UMCD000
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 4.1.3 Login to the Repeater NOTE: The Repeater is factory assigned the address 192.168.1.253. You will login for the first time using this address and make the necessary modifications according to information provided by your network administrator.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 4.2 &RQILJXULQJ 5) 3DUDPHWHUV DQG &KDQQHOV 7KH JDLQ UDQJH LV XS WR G% IRU DOO EDQGV DQG LV VHW E\ GHIDXOW WR LWV PD[LPXP YDOXH RI G% NOTE: The gain will then be modified automatically to its optimum value by the SALC mechanism. This mechanism performs gradual learning of traffic load characteristics and adjusts the Repeater RF Gain accordingly. (See section 1.4 for more information on the SALC mechanism).
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 6HW WKH 6\VWHP /HYHO SDUDPHWHUV • 5) 7UDQVPLVVLRQ (QDEOH ± GLVDEOHV DQG HQDEOHV XQLW 5) WUDQVPLVVLRQ 9HULI\ WKDW LW LV FKHFNHG 5) WUDQVPLVVLRQ 21 NOTE: RF transmission can be disabled by the system if the Shut Down mechanism is enabled and the criteria activated the mechanism is fulfilled. • 6KXW 'RZQ 0HFKDQLVP ± ZKHQ HQDEOHG WKH V\VWHP DXWRPDWLFDOO\ GLVDEOHV 5) WUDQVPLVVLRQ LI DQ H[FHVVLYHO\ KLJK LQSXW SRZHU IURP WKH %
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 'HILQH WKH 'RZQOLQN &KDQQHOV • 6HW WKH 6WDUW DQG 6WRS '/ )UHTXHQF\ 0+] 7KH 8SOLQN 6WDUW DQG 6WRS IUHTXHQFLHV ZLOO EH DXWRPDWLFDOO\ DOORFDWHG • 6XE EDQG UHVROXWLRQV UDQJLQJ EHWZHHQ .+] DQG 0+] FDQ EH DOORFDWHG WR D QDUURZEDQG RU ZLGHEDQG ILOWHU ,Q WKLV FDVH \RX ZLOO EH SURPSWHG WR VHOHFW WKH ILOWHU W\SH • o 6HOHFW WKH ILOWHU W\SH DQG FOLFN 6HOHFW DQG 5HWXUQ o &OLFN 6HQG DW WKH WRS RI WKH VFUHHQ 6
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL $IWHU WKH FKDQQHOV KDYH EHHQ FRQILJXUHG DQG WKH UHTXLUHG FRYHUDJH LV DWWDLQHG IRU WKH ORFDWLRQ YHULI\ WKDW QR $ODUPV DUH JHQHUDWHG • &OLFN WKH $ODUPV WDE • 9HULI\ WKDW DOO WKH LQGLFDWRUV DUH *5((1 LQ WKH $ODUPV WDE Figure 4-4. Alarms Dialog © Axell Wireless Ltd UMCD00013 Rev 2.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 4.3 6HWWLQJ 'DWH DQG 7LPH ,W LV LPSRUWDQW WR VHW WKH FRUUHFW GDWH DQG WLPH RQ WKH XQLW VLQFH WKLV SURYLGHV WKH WLPHVWDPS IRU HDFK ORJJHG HYHQW DQG DODUP To set the Repeaters date and time &OLFN RQ &08 LQ WKH WUHH SDQH &OLFN RQ 'DWH 7LPH LQ WKH PHQX EDU Click here 7KH IROORZLQJ GLDORJ DSSHDUV Figure 4-5.
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 4.4 &RQILJXULQJ WKH ([WHUQDO $ODUPV $Q\ FRQQHFWHG H[WHUQDO DODUPV VHFWLRQ PXVW EH HQDEOHG DQG FRQILJXUHG DFFRUGLQJ WR WKH LQVWUXFWLRQV SURYLGHG LQ WKLV VHFWLRQ To configure external alarms &OLFN RQ &08 LQ WKH WUHH SDQH DQG VHOHFW WKH ([WHUQDO $ODUPV WDE 7KH IROORZLQJ GLDORJ DSSHDUV External Alarms tab Click CMU Figure 4-6.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 4.5 6HWWLQJ WKH ,3 $GGUHVV 7KH 5HSHDWHU VXSSRUWV ERWK 6WDWLF DQG '+&3 DGGUHVVHV $ XQLTXH WHFKQRORJ\ HQDEOHV DSSO\LQJ ERWK W\SHV WR WKH VDPH (WKHUQHW SRUW %RWK DGGUHVVHV PD\ HQDEOH ORFDO DQG UHPRWH PDQDJHPHQW • /RFDO ,3 $GGUHVV ± 6WDWLF ,3 DVVLJQHG E\ WKH XVHU WR WKH V\VWHP 7KH GHIDXOW 6WDWLF ,3 DGGUHVV LV ,W LV KLJKO\ UHFRPPHQGHG WR SUHVHUYH WKLV VHWXS ,Q FDVH RI D FKDQJH PDNH VX
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 5 $GPLQLVWUDWLYH 2SHUDWLRQV 7KH IROORZLQJ DGPLQLVWUDWLYH RSHUDWLRQV DUH GHVFULEHG LQ WKLV VHFWLRQ • 8VHU 0DQDJHPHQW ± GHILQLQJ DQG FKDQJLQJ XVHUV DQG SDVVZRUGV • 9LHZLQJ WKH 5HSHDWHU LQIRUPDWLRQ VXFK DV VRIWZDUH DQG KDUGZDUH YHUVLRQV VHULDO QXPEHU • 6RIWZDUH XSJUDGH 5.1 8VHU 0DQDJHPHQW 7KLV VHFWLRQ GHVFULEHV KRZ WR SHUIRUP WKH XVHU PDQDJHPHQW RSHUDWLRQV %\ GHIDXOW WZR XVHUV EHORQJLQJ WR RQH RI WKUHH DXWKHQWLFDWLRQ
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 5.1.3 Adding Users NOTE: User name and password entries are case sensitive. To add a user )URP WKH 7UHH 3DQH VHOHFW 8VHUV 7KH OLVW RI XVHUV LV GLVSOD\HG LQ WKH 8VHU V 3DQH )URP WKH 8VHU V 3DQH FOLFN $GG 8VHU 7KH $GG 8VHU GLDORJ ER[ LV GLVSOD\HG Figure 5-2. Add User (QWHU WKH /RJLQ 1DPH ± QDPH XVHG E\ XVHU WR ORJLQ 7\SH WKH XVHU V )LUVW 1DPH DQG /DVW 1DPH ± XVHG WR LGHQWLI\ WKH XVHU 6HOHFW WKH 8V
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL &OLFN
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL Figure 5-5. Band Level Information 5.3 &RQILJXUDWLRQ )LOHV %DFNXS 5HVWRUH 7KH ' 0%5 36 :HE *8, PDQDJHPHQW DSSOLFDWLRQ HQDEOHV WKH EDFNXS DQG UHVWRUH RI WKH UHSHDWHU FRQILJXUDWLRQ ILOHV 7KH SURFHGXUHV DUH SHUIRUPHG YLD WKH %DFNXS 5HVWRUH WDE $ QXPEHU RI FRQILJXUDWLRQ ILOHV FDQ EH VWRUHG RQ WKH 5HSHDWHU IRU DFFHVV DW DQ\ WLPH
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 5.3.1 The Backup/Restore Tab To access Backup/Restore tab )URP WKH 7UHH 3DQH VHOHFW WKH UHOHYDQW EDQG DQG FOLFN WKH %DFNXS 5HVWRUH WDE 7KH IROORZLQJ VFUHHQ DSSHDUV 7KH VFUHHQ GLVSOD\V WKH FRQILJXUDWLRQ ILOHV FXUUHQWO\ DYDLODEOH RQ WKH 5HSHDWHU (DFK ILOH LV GLVSOD\HG DORQJ ZLWK WKH 5HSHDWHU VHULDO QXPEHU DQG LV QDPHG E\ GHIDXOW DFFRUGLQJ WR WKH GDWH RQ ZKLFK LW ZDV FUHDWHG D XVHU GHILQHG QDPH FDQ DOVR EH DVVLJQHG Cur
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 5.3.2 Backup of Repeater Configuration NOTE: The backed file will automatically be assigned a name according to the backup date and unit ID. The name cannot be modified while the backup file is saved onto the Repeater. However, before the backup procedure begins, the user may assign the file a recognizable name via the Remark field.
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 5.3.4 Uploading New Configuration File to Repeater To upload configuration file to Repeater &OLFN WKH 8SORDG EXWWRQ 6HOHFW WKH ILOH IURP WKH %URZVH GLDORJ DQG FOLFN 2SHQ 7KH ILOH DSSHDUV LQ WKH OLVW GLVSOD\HG LQ WKH %DFNXS 5HVWRUH WDEOH 5.3.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 5.4 CMU Software Upgrade 7KH SURFHGXUH GHVFULEHG LQ WKLV VHFWLRQ LV XVHG WR XSJUDGH WKH UHSHDWHU &08 NOTE: This procedure is performed for every new management version.
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL &KRRVH WKH UHTXLUHG VRIWZDUH ILOH DQG FOLFN ,QVWDOO 7KH $FWLYLW\ /RJ ZLOO LQGLFDWH VWDWXV DQG XSJUDGH FRPSOHWLRQ © Axell Wireless Ltd UMCD00013 Rev 2.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 46 UMCD00013 Rev 2.
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL 6 0RQLWRULQJ DQG 7URXEOHVKRRWLQJ 7KH ' 0%5 36 1)3$ SURYLGHV WZR W\SHV RI LQGLFDWLRQV RI IDLOXUH • )URQW SDQHO /(' • $ODUPV VFUHHQ LQ :HE DFFHVV DSSOLFDWLRQ • $ODUPV /RJ ± XVHG WR YLHZ D UHFRUG RI SDVW JHQHUDWHG DODUPV 7KH IROORZLQJ VHFWLRQV SURYLGH D GHVFULSWLRQ RI WKH WURXEOHVKRRWLQJ SURFHGXUHV DFFRUGLQJ WR WKH $ODUPV DQG ORJ RSWLRQV 6.
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 6.2 *8, $ODUP 'HVFULSWLRQV 7KH $ODUPV WDE SURYLGHV WKH DODUPV JHQHUDWHG E\ WKH 5HSHDWHU HQDEOLQJ WKH XVHU WR PRQLWRU WKH V\VWHP RSHUDWLRQ To access the Alarms window )URP WKH 7UHH 3DQH VHOHFW WKH LWHP DQG FKRRVH WKH $ODUPV WDE 1RWH WKDW VRPH DODUPV DUH GHGLFDWHG IRU WKH 8/ DQG '/ DQG RWKHU DODUPV DUH FRPPRQ WR WKH 8/ DQG '/ NOTE: Use the Ack All button to simultaneously acknowledge all triggered alarm
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL $ODUP )DXOW DQG PRVW SUREDEOH FDXVH DQG 5HFRPPHQGDWLRQ 5HFRPPHQGHG DFWLRQ &KHFN WKH 5HSHDWHU FDVH IRU H[WHUQDO FDXVHV VXQ KRW HQYLURQPHQW DLU IORZ LV EORFNHG (OLPLQDWH WKH UHDVRQ IRU H[FHVVLYH KHDW 'RQRU 3RZHU 7RR /RZ 'HVFULSWLRQ 6LJQDO IURP WKH 'RQRU DQWHQQD '/ LV WRR ORZ UHODWLYHO\ WR WKH GHVLUHG RXWSXW VLJQDO FRQILJXUHG E\ WKH XVHU 5HFRPPHQGHG DFWLRQ • &KHFN WKH 'RQRU %DVH FRQQHFWLRQV DQG DQWHQQD SRVLWLRQ
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL 6.3 Alarms Log 7KH $ODUPV /RJV VFUHHQ OLVWV WKH DODUPV HYHQWV WKDW KDYH RFFXUUHG 7KH &08 PDLQWDLQV ORJ ILOHV OLVWLQJ HYHU\ DODUP WULJJHUHG DQG LQ WKH 5HSHDWHU 7KLV VFUHHQ SURYLGHV DQ DQDO\VLV WRRO WR JHW LQIRUPDWLRQ RI DQ\ HYHQW WKDW KDV RFFXUUHG LWV RULJLQDWRU ZKHQ LI WKH\ UHWXUQ DQG WKHLU W\SH NOTE: Set the clock in order to synchronize the events time of occurrence (see 4.3).
Axell D-MBR 3007-3008-PS-NFPA PRODUCT DESCRIPTION AND USER’S MANUAL $SSHQGL[ $ 6SHFLILFDWLRQV 7KLV DSSHQGL[ SURYLGHV WKH HOHFWULFDO PHFKDQLFDO DQG HQYLURQPHQWDO VSHFLILFDWLRQV RI WKH $[HOO ' 0%5 36 1)3$ (OHFWULFDO 'RZQOLQN 8SOLQN )UHTXHQF\ 5DQJH 605 0+] ' EORFN 605 0+] 605 0+] 0+] 0+] 0+] 0+] 0+] 0+] 3DVVEDQG 0D[ *DLQ G% 3DVVEDQG DWWHQXDWLRQ UDQJH G% # G% VWHSV G% # G% VWHSV 3
AXELL D-MBR 3007-3008-PS NFPA REPEATER PRODUCT DESCRIPTION AND USER’S MANUAL (*)Every filter above 10 MHz utilizes 2 FPGA resources 2UGHULQJ ,QIRUPDWLRQ 52 ,'(17,),&$7,21 '(6&5,37,21 3$57 ' 0%5 36 1)3$ $& ' 0%5 36 'LJLWDO 0XOWL &KDQQHO 6HOHFWLYH 6LJQDO '%0 ),/ 1)3$ %RRVWHU FKDQQHOV G%P FRPSRVLWH SHU EDQG G% JDLQ $& DQG 5(' '& SRZHULQJ ZLWK 1)3$ DQG ,)& FRPSOLDQW $ODUP 2XWSXWV DQG UHG SDLQWHG FDVH ' 0%5 36 1)3$ '& 'LJLWDO 0XOWL &KDQQHO 6