User`s manual

16
ENGF-107 REV. A 01/11 © 2011 AXEON Water Technologies
NUMBER IDENTIFICATION
1. Solenoid Valve – Turns On/Off Feed Water
2. 5 Micron Sediment – Removes particulates
3. 10 Micron Carbon Block - Removes Chlorine
4. 1 Micron Sediment – Removes particulates
5. Pressure Gauge - Measures feed pressure
6. Pressure Gauge - Measures pressure after filters
7. Pressure Gauge - Measures pump pressure
8. Pressure Gauge – Measures concentrate pressure
9. Computer Control - Controls RO system
10. Recycle Valve – Recycles concentrate back to feed (If Applicable)
11. Concentrate Valve – Controls flow of concentrate (waste) water to the drain
12. RO Pump & Motor - Pressurizes RO System
13. Throttle Valve – Controls flow of the pump
14. Flow Meter - Measures flow of permeate water
15. Flow Meter - Measures flow of concentrate (waste) water
16. Flow Meter - Measures flow of concentrate recycle water (If Applicable)
17. Pressure Switch – Turns the Pump off at 15 PSI feed pressure
18. Permeate check Valve- Protects membranes from back pressure
19. Pressure Vessels – Houses Membrane Elements
20. TDS Meter – Reads the quality of the permeate water