% Rejection = [(Feed TDS – Product TDS) / Feed TDS] x 100
Example:
98.5% = [(550-8.25)/550] x 100
NOTE: ALL TDS FIGURES MUST BE EXPRESSED IN THE SAME UNITS,
TYPICALLY PARTS PER MILLION (PPM) OR MILLIGRAMS PER LITER (MG/L).
CT-Series reverse osmosis systems are designed to reject up to 98.5% NaCl, unless
computer projections have been provided or stated otherwise.
The amount of permeate water recovered for use is expressed as a percentage. To
calculate % recovery, use the following formula:
% Recovery = (Product Water Flow Rate / Feed Water Flow Rate) x 100
Example:
40% = (2.78/7.0) x 100
NOTE: ALL FLOW RATES MUST BE EXPRESSED IN THE SAME UNITS,
TYPICALLY GALLONS PER MINUTE (GPM).
SYSTEM REQUIREMENTS & OPERATION GUIDELINES
PLUMBING
The membranes and high pressure pumps used on CT-Series systems require a
continuous flow of water with a minimum feed pressure of 35 psi, not to exceed 105°F.
FEED WATER CONNECTION
1. Locate the 1” FNPT Solenoid Valve feed water inlet.
(Figure 1A, Page 14)
2. Attach the inlet piping to the 1” FNPT Solenoid Valve feed water inlet.
3. Be certain that all of the components of the feed water are soluble at the
concentrations attained in the system.
NOTE: FEED LINE MUST BE MINIMUM 3/4” INCH.