User`s guide
4: Setup and Conguration • 24
©2014 Axia Audio - Rev.1.3.8
This will commit Bank 1 to Bank 0 and Bank 1 would 
be available for a new upload.
Factory Reset (rackmount + Desktop)
Rackmounts and Desktop models provide an option 
to reset back to factory default. This is done by remov-
ing  power  from  the  unit.  Locate  the  ID  button  on  the 
back panel. Press and hold the button while power is ap-
plied to the unit. Keep pressing the button for about 10 
seconds. OLED models will provide a reset count down 
time on the display. Filmcap  models will ash the  but-
tons several times and then stop.
Display Tests (rackmount + Desktop)
The intercom stations have a test mode that tests the 
displays, buttons and provides an option to adjust the 
brightness. With power applied, press  and hold the  ID 
button for 10 seconds.
When in  test  mode, the four status  LEDs  (NET, 
SYNC, Livewire, Master) will scroll in sequence. OLED 
displays  will  show  TEST.  Pressing  a  button  will  illu-
minate the LED associated with the button. Pressing a 
button on lmcap models will engage the LED for the 
button. Each additional press will change the color of 
the  light (Green, Red, Yellow, none). Rotatingte  encod-
ers on OLED models will display numerical values on 
the OLED. For lmcap models, the buttons should be il-
luminated and rotating the knob will change the bright-
ness of the buttons.
Exit test mode is done so by pressing the ID button 
once on the rear panel.
Console modules can be tested by accessing the un-
derside of the module and rotating a 16 position switch 
to the F position. 