Datasheet
1
06-2015, Rev. 0515
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
AXICOM
Signal
Signal Relays
n
Telecom/signal relay (dry circuit, test access, ringing)
n
Slim line 14x9mm (.551x.354”)
n
Switching current 2A
n
2 form C bifurcated contacts (2 CO)
n
High sensitivity results in low nominal power consumption, 80mW
for high sensitive, 140mW for sensitive version
n
High mechanical shock resistance, up to 1500g survival
Typical applications
Communications equipment linecard application (ringing and test access),
PABX, voice over IP, office equipment, measurement and control equipment,
automotive equipment as CAN bus, keyless entry, speaker switch, medical
equipment, consumer electronics, set top boxes, HiFi.
Approvals
UL 508 File No. E 111441
Technical data of approved types on request
Contact Data
Contact arrangement 2 form C (CO)
Max. switching voltage 220VDC, 250VAC
Rated current 2A
Limiting continuous current, 85°C 2A
Switching Power 60W, 62.5VA
Contact material AgNi, gold-covered
Contact style bifurcated contact
Minimum switching voltage 100μV
Thermoelectrical potential <10µV
Initial contact resistance <50mΩ at 10mA
Frequency of operation, without load 50 operations/s
Operate time typ. 2ms, max. 4ms
Set/reset time typ. 2ms, max. 4ms
Release time
without diode in parallel typ. 2ms, max. 4ms
with diode in parallel typ. 4ms, max. 6ms
Bounce time typ. 1ms, max. 3ms
Electrical endurance
at 12V / 10mA typ. 5x10
7
operations
at 6V / 100mA typ. 1x10
7
operations
at 60V / 500mA typ. 5x10
5
operations
at 30V / 1000mA typ. 1x10
6
operations
at 30V / 2000mA typ. 2x10
5
operations
UL contact rating 50VDC / 2A - 100W
50VAC / 2A - 100W
30VDC / 2A - 60W
Mechanical endurance typ. 100x10
6
operations
Coil Data
Magnetic system polarized
Coil voltage range 2 to 24VDC
Max. coil temperature 125°C
Thermal resistance < 125K/W
Coil versions, monostable
Coil Rated Operate Limiting Release Coil Rated coil
code voltage voltage Voltage voltage resistance power
VDC VDC VDC VDC Ω±10% mW
Standard version, monostable
06 3 2.10 6.60 0.30 64 140
04 4.5 3.15 9.90 0.45 145 140
0 9 5 3.50 11.00 0.50 178 140
05 6 4.20 13.20 0.60 257 140
10 9 6.30 19.80 0.90 574 140
02 12 8.40 26.40 1.20 1028 140
12 24 16.80 44.30 2.40 2880 200
13 48 33.60 72.30 4.80 7680 300
High sensitive version, monostable
High sensitive version, monostable
21 3 2.25 8.70 0.30 113 80
22 4.5 3.38 13.10 0.45 253 80
23 5 3.75 14.60 0.50 313 80
24 6 4.50 17.50 0.60 450 80
25 9 6.75 24.20 0.90 1013 80
26 12 9.00 35.00 1.20 1800 80
27 24 18.00 52.80 2.40 4114 140
28 48 36.00 77.60 4.80 8882 260
All figures are given for coil without pre-energization, at ambient temperature +23°C.
FP2 Relay
DC current [A]
DC voltage [VDC]
Max. DC load breaking capacity
Z
108-98005 Rev. E
All specifications subject to change. Consult Tyco Electronics for latest specifications. 5 of 11
Telecom-, Signal and RF Relays
FP2 Relay
Coil Operating Range
U
nom
= Nominal coil voltage
U
max
= Upper limit of the operative range of
the coil voltage (limiting voltage)
U
op. min.
= Lower limit of the operative range of
the coil voltage (reliable operate voltage)
For latching relays U
set min.
resp. U
reset min.
U
rel. min.
= Lower limit of the operative range of
the coil voltage (reliable release voltage)
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
2.6
2.8
3
3.2
3.4
-60 -50 -40 -30 -20 -10 0102030405060708090100 110120
0.0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
-60-50 -40-30 -20-10 0102030405060708090100 110 120
Umax. at 0 A
Umax. at 2 x 2 A
Umax. at 2 x 1 A
U
nom.
nominal coil voltage
Uop. min.
Urel. min.
Ambient Temperature [°C]
Coil Voltage [U/U
nom]
Umax. at 0 A
Umax. at 2 x 2 A
Umax. at 2 x 1 A
Uop. min.
Urel. min.
Ambient Temperature [°C]
Coil Voltage [U/U
nom
]
Unom. nominal coil voltage
0
0.2
0.4
0.6
0.8
1
1.2
1.4
1.6
1.8
2
2.2
2.4
2.6
2.8
3
3.2
3.4
3.6
3.8
4
4.2
4.4
4.6
-60-50 -40-30 -20-10 0102030405060708090100 110 120 130 140
Uset min.
Ambient Temperature [°C]
Coil Voltage [U/Unom]
Unom. nominal coil voltage
80 mW
140 mW
200 mW
260 mW
300 mW
Umax. - 5 % coil duty at 2 x 2 A
Umax. - 5 % coil duty at 0 A
U
max. - 5 % coil duty at 2 x 1 A
U
max.
- 100 % coil duty at 0 A
200 mW Latching
100 mW Latching