AXICOM Telecom-, Signal and RF Relays Cradle Relay S V23054 / V23062 108-98014 • Nov. 07 • Rev.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Hand solder and plug-in relay, for DC operation, non-polarized, non-latching ROHS compliant (Directive 2002/95/EC) as per product date code 0501. Features • Stronger magnet system and thus wider voltage range than cradle relay N • highly reliable • Contacts for signal loads and currents up to 5 A • AC and DC, latching and non-latching, coils operating voltage 6 V ...
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Dimensions Type V23062-Axxx Size I Dimensions in mm Type V23062-Bxxx Size II Hand solder terminals, silver-plated Also for plug-in connection and screw fixing With earth terminal hermeticaly sealed with metal enclosure For sockets and hold-down springs see data sheet Accessories All specifications subject to change. Consult Tyco Electronics for latest specifications.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Coil Data and operating range Nominal voltage from 6 Vdc to 220 Vdc Typical nominal power consumption, at 20 °C Class of the operative range acc to EN 61810-1 / IEC 61810-1 and VDE 0435 Part 201 Operating voltage (according to the coil type) 1W 2 max.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Coil Data (values at 23 °C) Nominal voltage Unom Vdc Operate/set voltage range Ordering Information Coil power Coil Resistance Ω / ± 15 % Relay code Tyco part number Minimum voltage Umin Maximum voltage Umax Vdc Vdc mW 190 18 21.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Coil Data (values at 23 °C) Nominal voltage Unom Operate/set voltage range Ordering Information Coil power Coil Resistance Ω / ± 15 % Relay code Tyco part number Minimum voltage Umin Maximum voltage Umax Vdc Vdc mW V23054-DXXXX standard, size II 125 59 12 4.7 12.5 5.4 16 7 16 7 20 10.5 20 10.5 20 10.5 220 79 125 59 24 10.5 32 14.5 32 14.5 60 29 60 29 24 10.5 24 10.5 24 13 24 13 32 14.5 32 17.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Coil Data (values at 23 °C) Nominal voltage Unom Operate/set voltage range Ordering Information Coil power Coil Resistance Ω / ± 15 % Relay code Tyco part number Minimum voltage Umin Maximum voltage Umax Vdc Vdc mW V23054-EXXXX standard, size III 8.4 4.4 12 5.8 12 8.8 12.5 6.9 12.5 10 16 8.7 16 13 20 10.5 20 15.5 20 15.5 110 53.5 125 73 60 36 24 13 24 13 24 13 24 20 24 20 32 17.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Instructions for Impulse Operation The maximum voltage stated in the table (page 6) can be increased for impulse operation as follows: UII Impuls = UII tamb = q = UII tamb . q Maximum continuous voltage at ambient temperature t amb Factor The impulse voltage must not exceed 80% of the test voltage (winding/frame or winding/winding) or not to exceed the max. voltage as listed in the table (page 6) by no more than 2.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Contact Data B104/B110/ B112/B133 Ordering code block 3 B604/B610/ C104/C110/ C404/C410 B612/B633 C112/C133 C412/C433 max. 6 changeover contacts or 6 make contacts Number of contacts and Type Contact assembly single contacts silver, gold F gold-flashed 150 Vdc 36 Vdc Contact material Max. switching voltage Max. switching current Max.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 Insulation Ordering code block 3 Test voltage (1 min) winding / frame contact / contact contact / frame B1xx B6xx C1xx C4xx 500 Vacrms 500 Vacrms 500 Vacrms F1xx 500 Vacrms 1000 Vacrms 1000 Vacrms General Data Ordering code block 3 Operate time at Unom and 20 °C, typical Reset time typical B1xx B6xx C1xx 16 ms 2 ms Maximum switching rate without load 50 operations/s Ambient temperature range acc.
AXICOM Telecom-, Signal and RF Relays 108-98014 Rev. C Cradle Relay S V23054/V23062 IM Relays D2n Relays 4th generation slim line – low profile polarized 2 c/o telecom signal relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 1.5 ... 24 V, coil power consumption of 50 ... 200 mW, latching relays with 1 coil 100 mW.
Tyco Electronics Logistics AG Werk Axicom Au Seestrasse 295 CH-8804 Au-Wädenswil / Switzerland Phone +41 44 782 91 11 Fax +41 44 782 90 00 E-mail: axicom@tycoelectronics.com Tyco Electronics Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38573 Fax +49 30 386 38575 E-mail: axicom@tycoelectronics.com Tyco Electronics EC Trutnov s.r.o. Komenského 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.