INSTALLATION GUIDE ENGLISH AXIS Q87-E Power Supply 230 V AC AXIS Q87-E Power Supply 120 V AC
Electromagnetic Compatibility (EMC) This equipment has been designed and tested to fulfill applicable standards for: • Radio frequency emission when installed according to the instructions and used in its intended environment. • Immunity to electrical and electromagnetic phenomena when installed according to the instructions and used in its intended environment.
Safeguards Please read through this Installation Guide carefully before installing the product. Keep the Installation Guide for further reference. • • • • • • • • This Axis product shall be used in compliance with local laws and regulations. The Axis product should be installed by a trained professional. Please observe relevant national and local regulations for the installation.
AXIS Q87-E 230/120 V AC Installation Guide Page 5 AXIS Q87-E Power Supply 230 V AC & AXIS Q87-E Power Supply 120 V AC Installation Guide This Installation Guide provides instructions for connecting AXIS Q87-E Power Supply 230/120 V AC with AXIS Q87-E Dual PTZ Network Camera Series. 1. Check the package contents against the list below. 2. Hardware overview. See page 6. 3. Install the Power Supply. See page 7.
Page 6 AXIS Q87-E 230/120 V AC Installation Guide Hardware Overview 1 2 3 4 5 6 7 1 2 3 4 8 Power supply lid Power supply lid screw (4x) Cable gland (mains power) Cable gland (unit power) 5 6 7 8 Cable gland (illuminator cable) Power supply box Day/night sensor Connector board
AXIS Q87-E 230/120 V AC Installation Guide Page 7 Install the Power Supply The mains supply shall be disconnected during installation. The supplied power supply shall be used. Using any other power supply will void the warranty and could leave the unit at a risk. 1. Install the power supply in the desired location. Make sure that the screws and plugs are appropriate for the material (e.g. wood, metal, sheet rock, stone). 2. Unscrew the lid screws and open the power supply. 3.
Page 8 AXIS Q87-E 230/120 V AC Installation Guide 4. Connect the pan/tilt power supply to the pan/tilt connector (6) in the power supply. 5. If using the day/night sensor, connect the illuminator cable to the illuminator connector (J5) in the power supply. 6. If using the day/night sensor, adjust the potentiometer to increase or decrease the sensitivity of the day/night sensor. see Connection Diagram, on page 9. Connect the mains supply cable to the mains supply connector in the power supply.
AXIS Q87-E 230/120 V AC Installation Guide Page 9 Connection Diagram L 1 N INCOMING MAINS VOLTAGE L N 3 AXIS Q87-E POWER SUPPLY PE EXTERNAL PROTECTIVE GROUND WIRE 1 2 3 Incoming mains voltage External protective ground wire AXIS Q87-E Power Supply Cable Specification Notes: • To maintain the products IP rating, the external diameter of the cables must be 5 - 10 mm. • The Pan/tilt power supply cable can not be longer than 3 m (9 ft).
Day/Night Sensor The day/night sensor is configured in the factory for optimal performance in a range of conditions. However, settings can be adjusted to suit specific conditions on site. To adjust the sensitivity of the day/night sensor, turn the potentiometer until it reaches the desired threshold. Turn the potentiometer clockwise to increase the threshold and advance the switch to night mode. Turn the potentiometer counterclockwise to decrease the threshold and delay the switch to night mode.