Function/group
Item
Specications
Operating
conditions
0 ºC to 40 ºC (32 ºF to 104 ºF)
Humidity 20–80% RH (non-condensing)
Approvals EN 301489-1, EN 301489-17
EN 55022 Class B, EN 61000-3-2, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2,
EN 55024
EN 62311:2008, EN 300 328
FCC Part 1 5 Subpart B and C Class B, VCCI Class B, C-tick AS/NZS CISPR 22,
ICES-003 Class B, KCC Class B
EN 60950-1
SRRC, ANATEL, TELEC, RSS-210, AS/NZS 4771
EN/IEC 62741 (risk group 1)
Power sup ply: EN 60950-1, cCSAus
Dimensions
(HxWxD)
34 mm x 59 mm x 95 mm (1.3” x 2.3” x 3.7”)
Weight
Camera: 0.118 kg (0.26 l b.)
Included
accessories
Power supply, stand and clamp, extension for stand 100 mm (4.0”), Q uick Guide,
Installation and Management Software CD, Windows decoder 1-user license
Video
management
software
AXIS Camera Companion ( s o ftw are included on CD) Basic surveillance for small
businesses, where video is recorded to edge storage
AXIS Camera Station ( s old separately) Full y featured surveillance for medium-sized
installations, where video i s recorde d on a syste m serve r For more information and
software applications from partners, see www.axis.com/products/video/software/
Optional
accessories
PoE Active Splitter
Installation Displa y
Network I/O Audio Module
Connectors
I/O terminal connector
4–pin terminal block for:
Digital Input
Digital Output
Auxiliary power and ground (GND)
1 2 3 4
Function Pin Notes
Specications
GND
1
Ground
3.3 V DC Power
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Max load = 50 mA
Digital Input
3
Connect to GND to activate, or leave oating (unconnected)
to deactivate.
0to+40VDC
Digita
lOutput
4
Internal connection to ground when activated, oating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection against voltage trans ients .
Max load =100 mA
Max voltage = +40 V DC