About this Document This manual is intended for administrators and users of the AXIS P5414–E PTZ Dome Network Camera, and is applicable to firmware 5.55 and later. It includes instructions for using and managing the product on your network. Previous experience of networking will be of use when using this product. Some knowledge of UNIX or Linux-based systems may also be beneficial, for developing shell scripts and applications. Later versions of this document will be posted to the Axis website, as required.
Europe This symbol means that the product shall not be disposed of together with household or commercial waste. Directive 2012/19/EU on waste electrical and electronic equipment (WEEE) is applicable in the European Union member states. To prevent potential harm to human health and the environment, the product must be disposed of in an approved and environmentally safe recycling process.
AXIS P5414–E PTZ Dome Network Camera Table of Contents Hardware Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connectors and Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessing the Product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Access from a Browser . . . . .
AXIS P5414–E PTZ Dome Network Camera Table of Contents Upgrading the Firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Symptoms, Possible Causes and Remedial Actions . . . . . . . . . . . . . . . . . . . . . Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Performance Considerations . . . . . . . . .
AXIS P5414–E PTZ Dome Network Camera Hardware Overview Hardware Overview 1 1 2 3 4 5 6 7 8 2 3 4 5 6 Control button Status LED indicator SD memory card slot Audio connector I/O connector Power connector Network connector (PoE+) Part number (P/N) & Serial number (S/N) Connectors and Buttons For technical specifications, see page 59. Network Connector RJ45 Ethernet connector. Supports Power over Ethernet Plus (PoE+).
AXIS P5414–E PTZ Dome Network Camera Hardware Overview I/O Connector Use in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications. In addition to an auxiliary power and a GND pin, the I/O terminal connector provides the interface to: • Digital output – For connecting external devices such as relays and LEDs. Connected devices can be activated by the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule.
AXIS P5414–E PTZ Dome Network Camera Accessing the Product Accessing the Product To install the Axis product, refer to the Installation Guide supplied with the product. The product can be used with most operating systems and browsers. The recommended browsers are Internet Explorer with Windows, Safari with Macintosh and Firefox with other operating systems. See Technical Specifications, on page 59. To view streaming video in Internet Explorer, allow installation of AXIS Media Control (AMC) when prompted.
AXIS P5414–E PTZ Dome Network Camera Accessing the Product Access from the Internet Once connected, the Axis product is accessible on your local network (LAN). To access the product from the Internet you must configure your network router to allow incoming data traffic to the product. To do this, enable the NAT-traversal feature, which will attempt to automatically configure the router to allow access to the product. This is enabled from Setup > System Options > Network > TCP/IP Advanced.
AXIS P5414–E PTZ Dome Network Camera Accessing the Product Click the Active/Inactive buttons to manually activate and inactive the product’s output port. For information about how to enable and configure output buttons, see page 25. The Manual Trigger button is used to trigger an action rule from the Live View page. For information about how to configure and enable the button, see Manual Trigger, on page 10. Click Snapshot to save a snapshot of the video image.
AXIS P5414–E PTZ Dome Network Camera Accessing the Product Click the View Full Screen button and the video image will fill the entire screen. Press ESC (Escape) on the computer keyboard to cancel full screen view. The Record button is used to record the current video stream. The location where the recording is saved can be specified in the AMC Control Panel. Enable this button from Live View Config > Viewer Settings.
AXIS P5414–E PTZ Dome Network Camera Accessing the Product Pan and Tilt bars – Use the arrows to pan and tilt the camera view, or click on a position on the bar to steer the camera view to that position. Zoom bar – Use the arrows to zoom in and out, or click on a position on the bar to zoom to that position. Focus bar – Use the arrows to focus the camera, or click on a position on the bar to set the focus position. Using the focus bar will disable the product’s autofocus.
AXIS P5414–E PTZ Dome Network Camera Media Streams Media Streams The Axis product provides several audio and video stream formats. Your requirements and the properties of your network will determine the type you use. The Live View page in the product provides access to H.264 and Motion JPEG video streams, audio streams and to the list of available stream profiles. Other applications and clients can access video and audio streams directly, without going via the Live View page. How to Stream H.
AXIS P5414–E PTZ Dome Network Camera Media Streams The AMC Control Panel can be used to configure various video and audio settings. Please see the AXIS Media Control User’s Manual for more information. The AMC Control Panel is automatically installed on first use, after which it can be configured. Open the AMC Control Panel from: • Windows Control Panel (from the Start menu) • Alternatively, right-click the video image in Internet Explorer and click Settings.
AXIS P5414–E PTZ Dome Network Camera Media Streams Note • = IP addess • The Axis product supports QuickTime 6.5.1 and later. • QuickTime adds latency to the video stream. • It may be possible to use other players to view the H.264 stream using the paths above, although Axis does not guarantee this.
AXIS P5414–E PTZ Dome Network Camera Setting Up the Product Setting Up the Product The Axis product can be configured by users with administrator or operator rights. To open the product’s Setup pages, click Setup in the top right-hand corner of the Live View page. • Administrators have unrestricted access to all settings. • Operators have access to all settings except System Options See also the online help .
AXIS P5414–E PTZ Dome Network Camera Video and Audio Video and Audio The video and audio settings can be used to optimize video and audio quality. You can configure the following: • Video stream settings. See page 17. • Stream profiles. See page 18. • Camera settings. See page 18. • Overlay image. See page 20. • Privacy mask. See page 22. • Audio settings. See page 22. • Audio clips. See page 23.
AXIS P5414–E PTZ Dome Network Camera Video and Audio • Rotate image. If required, the image can be rotated. • Maximum frame rate. To avoid bandwidth problems, the frame rate allowed to each viewer can be Limited to a fixed amount. Alternatively, the frame rate can be set as Unlimited, which means the Axis product always delivers the highest frame rate possible under the current conditions. • Overlay settings. See Overlay, on page 20. Click Save to apply the new settings. H.264 H.
AXIS P5414–E PTZ Dome Network Camera Video and Audio Image Appearance Increasing the Color level increases the color saturation. The value 100 gives maximum color saturation. The value 0 gives a black and white image. The image Brightness can be adjusted in the range 0–100, where a higher value produces a brighter image. Increasing the Sharpness can increase bandwidth usage. A sharper image might increase image noise especially in low light conditions.
AXIS P5414–E PTZ Dome Network Camera Video and Audio Gain, measured in decibel (dB), is the amount of amplification applied to the image. A high gain may provide a better image in low light situations but will increase the amount of image noise. Set Gain to • Auto to set the gain automatically. If required, use Max gain to limit the applied gain. • Fixed to use a fixed gain.
AXIS P5414–E PTZ Dome Network Camera Video and Audio Overlay Image An overlay image is a static image superimposed over the video stream. The image, for example company logo, is used to provide extra information or to mask a part of the image. Since it is static, the position and size of an overlay image will remain the same regardless of resolution and Pan/Tilt/Zoom movements. To set up a dynamic mask, which will always mask the specified part of monitored area, see Privacy Mask.
AXIS P5414–E PTZ Dome Network Camera Video and Audio Privacy Mask A privacy mask is an area of solid color that prohibits users from viewing parts of the monitored area. Privacy masks cannot be bypassed via the VAPIX® Application Programming Interface (API). The Privacy Mask List, Video & Audio > Privacy Mask, shows all the masks that are currently configured in the Axis product and indicates if they are enabled.
AXIS P5414–E PTZ Dome Network Camera Video and Audio • Yellow — the signal is becoming distorted. • Red — the signal is distorted. Use the Encoding option to select digital audio encoding format. • AAC requires a license for both encoding and decoding. AAC is the least complicated and most widely used codec. If achieving the best possible audio quality is a priority, AAC is the recommended codec to use. An AAC license is included in the Axis product.
AXIS P5414–E PTZ Dome Network Camera Live View Config Live View Config You can customize the Live View page and alter it to suit your requirements. It is possible to define the following features of the Live View page. • Stream Profile. See page 18. • Default Viewer for Browser. See page 24. • Viewer Settings. See page 25. • Action Buttons. These are the buttons described in Controls on the Live View Page, on page 9 . • User Defined Links. See page 25. • Output Buttons. See page 25.
AXIS P5414–E PTZ Dome Network Camera Live View Config Browser Viewer Description Windows Internet Explorer AMC Recommended viewer in Internet Explorer (H.264/Motion JPEG). QuickTime H.264. Java applet A slower imaging alternative to AMC (Motion JPEG). Requires one of the following installed on the client: • JVM (J2SE) 1.4.2 or higher. • JRE (J2SE) 5.0 or higher. Still image Displays still images only. Click the Refresh button in your browser to view a new image.
AXIS P5414–E PTZ Dome Network Camera Live View Config - Pulse activates the output for a defined period of time. The pulse time can be set from 1/100 second to 60 seconds. - Active/Inactive displays two buttons, one or each action. To configure the active and inactive states, go to System Options > Ports & Devices > I/O Ports and set the port’s Normal state. For more information about I/O ports, see I/O Ports, on page 51.
AXIS P5414–E PTZ Dome Network Camera PTZ (Pan Tilt Zoom) PTZ (Pan Tilt Zoom) Preset Positions A preset position is a predefined view that can be used to quickly steer the camera to a specific location. Preset positions can be accessed in several ways: • By selecting the preset from the Preset positions drop-down list in the Live View Page. • When setting up action rules. See page 35. • When setting up Guard Tour. See page 28. • When setting up the Gatekeeper. See page 28 To add a preset position: 1.
AXIS P5414–E PTZ Dome Network Camera PTZ (Pan Tilt Zoom) Gatekeeper The Advanced Gatekeeper monitors an area such as an entrance gate. When motion is detected in the monitored area, the Gatekeeper will steer the camera to a selected preset position. Using a zoomed-in preset position can make it possible to, for example, read a license plate or identify a person. When motion is no longer detected, the camera returns to its Home position after a defined time.
AXIS P5414–E PTZ Dome Network Camera PTZ (Pan Tilt Zoom) Click Get to set the coordinates. Proceed to where the upper right point of zone should be located and click Get. Give the zone a descriptive name and click OK. To include the name of the OSDI zone in the overlay text, go to Video & Audio < Video Stream < Overlay Settings. Check the Include text box and enter the modifier #L in the field. For more information about modifiers, see File Naming & Date/Time Formats in the online help .
AXIS P5414–E PTZ Dome Network Camera PTZ (Pan Tilt Zoom) Note • The administrator can enable and disable PTZ controls for selected users. • To identify different users in the viewer group, cookies must be enabled on the client.
AXIS P5414–E PTZ Dome Network Camera Detectors Detectors Motion Detection Motion detection is used to generate an alarm whenever movement starts or stops in the camera view. Motion detection is configured by defining up to 10 Include and Exclude windows: • Include windows — define areas where motion should be detected • Exclude windows — define areas within an Include window that should be ignored (areas outside Include windows are automatically ignored).
AXIS P5414–E PTZ Dome Network Camera Detectors Motion Detection Parameters The parameters controlling motion detection are described in the table below: Parameter Object Size History Sensitivity Description Object size relative to window size. Object memory length. Difference in luminance between background and object. High level (100%) Only very large objects trigger motion detection.
AXIS P5414–E PTZ Dome Network Camera Applications Applications Third party applications can be uploaded to and installed on the Axis product. Applications add functionality to the product, for example video analytics and intelligent video capabilities such as recognition, tracking, detection and counting. For information about available applications, downloads, trials and licenses, go to www.axis.com/applications Note • It is recommended to run one application at a time.
AXIS P5414–E PTZ Dome Network Camera Applications If the Axis product is reset to factory default, installed applications and their settings are removed. For information about factory default, see Reset to Factory Default Settings.
AXIS P5414–E PTZ Dome Network Camera Events Events The Axis product can be configured to perform actions when different events occur, for example, start a recording when motion is detected. The set of conditions that defines how and when the action is triggered is called an Action Rule. Available Action Rule triggers and conditions include: • Applications — use installed applications to trigger the rule, see Applications, on page 33.
AXIS P5414–E PTZ Dome Network Camera Events - • • Recording — triggers the rule when the Axis product records to the storage device. The recording status trigger can be used to notify the operator, for example by flashing LED lights, if the product has started or stopped to record to the storage device. Note that, this trigger can be used only for edge storage recording status. System - System Ready — trigger the rule when the product has been started and all services are running.
AXIS P5414–E PTZ Dome Network Camera Events 6. Under Actions, select Record Video from the Type drop-down list. 7. Select a Stream profile and configure the Duration settings as described below. 8. Select Network Share from the Storage drop-down list. To add additional criteria, select the Additional conditions option and add additional triggers. To prevent an action from being triggered repeatedly, a Wait at least time can be set.
AXIS P5414–E PTZ Dome Network Camera Events 2. Enter a descriptive name. 3. Select a recipient Type. 4. Enter the information needed for the recipient type. 5. Click Test to test the connection to the recipient. 6. Click OK. Setting Up an Email Recipient Email recipients can be configured by selecting one of the listed email providers, or by specifying the SMTP server, port and authentication used by, for example, a corporate email server.
AXIS P5414–E PTZ Dome Network Camera Events 1. Go to Events > Recurrences and click Add. 2. Enter a descriptive name and recurrence pattern. 3. Click OK. To use the recurrence in an Action Rule, first select Time from the Trigger drop-down list in the Action Rule Setup page and then select the recurrence from the second drop-down list. To modify or remove recurrences, select the recurrence in the Recurrences List and click Modify or Remove.
AXIS P5414–E PTZ Dome Network Camera Recordings Recordings The Axis product can be configured to record video continuously or according to an action rule: • To start a continuous recording, see page 40. • To set up action rules, see page 36. • To access recordings, see Recording List, on page 40. • To configure camera controlled storage, see Storage, on page 50. Recording List Recorded videos are listed on the Recordings > List page.
AXIS P5414–E PTZ Dome Network Camera Languages Languages Multiple languages can be installed in the Axis product. All web pages including the online help will be displayed in the selected language. To switch languages, go to Setup > Languages and first upload the new language file. Browse and locate the file and click the Upload Language button. Select the new language from the list and click Save.
AXIS P5414–E PTZ Dome Network Camera System Options System Options Security Users User access control is enabled by default and can be configured under System Options > Security > Users. An administrator can set up other users by giving them user names and passwords. It is also possible to allow anonymous viewer login, which means that anybody may access the Live View page.
AXIS P5414–E PTZ Dome Network Camera System Options 2. Select an HTTPS certificate from the list of installed certificates. 3. Optionally, click Ciphers and select the encryption algorithms to use for SSL. 4. Set the HTTPS Connection Policy for the different user groups. 5. Click Save to enable the settings. To access the Axis product via the desired protocol, enter https:// or http:// in the address field in a browser. The HTTPS port can be changed on the System Options > Network > TCP/IP > Advanced page.
AXIS P5414–E PTZ Dome Network Camera System Options To install a self-signed certificate: 1. Go to System Options > Security > Certificates. 2. Click Create self-signed certificate and provide the requested information. To create and install a CA-signed certificate: 1. Create a self-signed certificate as described above. 2. Go to System Options > Security > Certificates. 3. Click Create certificate signing request and provide the requested information. 4.
AXIS P5414–E PTZ Dome Network Camera System Options Network Basic TCP/IP Settings The Axis product supports IP version 4 and IP version 6. Both versions can be enabled simultaneously, and at least one version must always be enabled. IPv4 Address Configuration By default, the Axis product is set to use IPv4 (IP version 4) and to obtain the IP address automatically via DHCP. The IPv4 settings are configured under System Options > Network > TCP/IP > Basic.
AXIS P5414–E PTZ Dome Network Camera System Options ping -l 408 -t Windows example (this may require that you run the command prompt as an administrator) arp -s 192.168.0.125 00-40-8c-18-10-00 ping -l 408 -t 192.168.0.125 4. Check that the network cable is connected and then restart the product by disconnecting and reconnecting power. 5. Close the command prompt when the product responds with Reply from 192.168.0.125:... or similar. 6.
AXIS P5414–E PTZ Dome Network Camera System Options Primary/Secondary DNS server - Enter the IP addresses of the primary and secondary DNS servers. The secondary DNS server is optional and will be used if the primary is unavailable. NTP Configuration NTP (Network Time Protocol) is used to synchronize the clock times of devices in a network. The NTP settings are configured under System Options > Network > TCP/IP > Advanced.
AXIS P5414–E PTZ Dome Network Camera System Options Enable/Disable - When enabled, the Axis product attempts to configure port mapping in a NAT router on your network, using UPnPTM. Note that UPnPTM must be enabled in the product (see System Options > Network > UPnP). Use manually selected NAT router - Select this option to manually select a NAT router and enter the IP address for the router in the field. If no router is specified, the product automatically searches for NAT routers on your network.
AXIS P5414–E PTZ Dome Network Camera System Options Enter the host names or IP addresses and port numbers for the primary and secondary mail servers in the fields provided. A From email address is also required. If the mail server requires authentication, check Use authentication to log in to this server and enter the necessary information. SNMP The Simple Network Management Protocol (SNMP) allows remote management of network devices.
AXIS P5414–E PTZ Dome Network Camera System Options Bonjour The Axis product includes support for Bonjour. Bonjour is enabled by default and the product is automatically detected by operating systems and clients that support this protocol. Bonjour can be disabled under System Options > Network > Bonjour. Storage SD Card The Axis product supports SD cards with up to 64 GB of storage. For best recording performance, use an SDHC or SDXC card with speed class 10.
AXIS P5414–E PTZ Dome Network Camera System Options To add a network share: 1. Go to System Options > Storage. 2. Click Network Share. 3. Enter the IP address, DNS or Bonjour name to the host server in the Host field. 4. Enter the name of the share in the Share field. Sub folders cannot be used. 5. If required, select The share requires login and enter the user name and password. 6. Click Connect.
AXIS P5414–E PTZ Dome Network Camera System Options For information about firmware upgrade, see Upgrading the Firmware, on page 55. Support Support Overview The System Options > Support > Support Overview page provides information on troubleshooting and contact information, should you require technical assistance. See also Troubleshooting, on page 55. System Overview To get an overview of the Axis product’s status and settings, go to System Options > Support > System Overview.
AXIS P5414–E PTZ Dome Network Camera System Options To open the Script Editor, go to System Options > Advanced > Scripting. If a script causes problems, reset the product to its factory default settings, see page 53. For more information, see www.axis.com/developer File Upload Files, for example web pages and images, can be uploaded to the Axis product and used as custom settings. To upload a file, go to System Options > Advanced > File Upload.
AXIS P5414–E PTZ Dome Network Camera Repainting the Camera Repainting the Camera The covers can be repainted to match the installation environment. The material used in the covers is ASA Geloy XTWM206. Use paint suitable for this material. 1. Remove the two top cover screws. 2. Use a thin palette knife to release the locking tabs while pulling the top cover straight upwards to remove the cover. 3. Remove the two bottom cover screws and remove the bottom cover. 4.
AXIS P5414–E PTZ Dome Network Camera Troubleshooting Troubleshooting Checking the Firmware Firmware is software that determines the functionality of network devices. One of your first actions when troubleshooting a problem should be to check the current firmware version. The latest version may contain a correction that fixes your particular problem. The current firmware version in the Axis product is displayed in the page Setup > Basic Setup and in Setup > About.
AXIS P5414–E PTZ Dome Network Camera Troubleshooting arp -s temp ping -l 408 In Windows, type the following from a command/DOS prompt (this may require that you run the command prompt as an administrator): arp -s ping -l 408 -t 2. If the product does not reply in 30 seconds, restart it and wait for a reply. Press CTRL+C to stop Ping. 3. Open a browser and type in the product’s IP address.
AXIS P5414–E PTZ Dome Network Camera Troubleshooting The IP address has been changed by DHCP IP addresses obtained from a DHCP server are dynamic and may change. If the IP address has been changed, use AXIS IP Utility or AXIS Camera Management to locate the product on the network. Identify the product using its model or serial number, or by the DNS name (if the name has been configured). If required, a static IP address can be assigned manually.
AXIS P5414–E PTZ Dome Network Camera Troubleshooting Lower frame rate than expected See Performance Considerations, on page 63. Reduce the number of applications running on the client computer. Limit the number of simultaneous viewers. Check with the network administrator that there is enough bandwidth available. Check in the AMC Control Panel (H.264 tag) that video processing is NOT set to Decode only key frames. Lower the image resolution.
AXIS P5414–E PTZ Dome Network Camera Technical Specifications Technical Specifications Function/group Item Specifications Camera Models AXIS P5414–E 50 Hz AXIS P5414–E 60 Hz Image sensor 1/2.9” progressive scan RGB CMOS Lens f=4.7 mm – 84.6 mm F1.6 — 2.8 Autofocus Automatic day and night functionality Horizontal angle of view: 59° — 4° Minimum illumination Color: 0.4 lux at 30 IRE F1.6 B/W: 0.04 lux at 30 IRE F1.6 Shutter time 1/28000 s to 2 s Pan/Tilt/Zoom Pan ±135°, 0.
AXIS P5414–E PTZ Dome Network Camera Technical Specifications Function/group Item Specifications Network Security Password protection, IP address filtering, HTTPS encryption*, IEEE 802.1X network access control*, digest authentication, user access log *This product includes software developed by the Open SSL Project for use in the Open SSL Toolkit (www.openssl.
AXIS P5414–E PTZ Dome Network Camera Technical Specifications Function/group Item Specifications General Casing IP66– and NEMA 4X–rated metal casing (aluminum), clear dome (PC), sunshield (ASA) memory 256MB RAM, 128 MB Flash Power Power over Ethernet Plus (PoE+) IEEE 802.
AXIS P5414–E PTZ Dome Network Camera Technical Specifications Configurable (Input or Output) 3–6 Digital input — Connect to GND to activate, or leave floating (unconnected) to deactivate. 0 to +30 V DC Digital output — Internal connection to ground when activated, floating (unconnected) when deactivated. If used with an inductive load, e.g. a relay, a diode must be connected in parallel with the load, for protection against voltage transients.
AXIS P5414–E PTZ Dome Network Camera Technical Specifications Function Pin Notes Microphone/Line in 1 Microphone or line in (mono) GND 2 Ground Line out 3 Line audio out GND 4 Ground SD Card Slot Supports SD cards with up to 64 GB of storage. For best recording performance, use an SDHC or SDXC card with speed class 10. Performance Considerations When settings up your system, it is important to consider how various settings and situations will affect performance.
User Manual AXIS P5414–E PTZ Dome Network Camera © Axis Communications AB, 2013 Ver. M2.2 Date: November 2013 Part No.