User's Manual

AXIS P5532 PTZ Dome Network Camera
Events
Events
The Axis product can be congured to perform actions whe n d ifferent events occur, for example, star t a recording when motion is
detected. The set of conditions that denes how and when the action is triggered is called an Action Rule.
Available Action Rule triggers and conditions include:
Applications use installed applications to trigger the rule, see Applications, on page 30.
Detectors
- Audio Detection trigger the rule when audio is detected, see Audio detection, on page 29.
- Motion Detection trigger the rule when motion is detected, see Motion Detection, on page 28.
Hardware
- Fan trigger the rule i f the fan i s m alfunctioning. Thiscanforexamplebeusedtosendmaintenance
notications.
- Network trigger the rule if network connection is lost or restored. This can for example be used to start
recording to the SD card.
- Temperature trigger the rule if the tempera ture falls outside o r inside the operating range of the product. This
canforexamplebeusedtosendmaintenancenotications.
Input Signal
- Digital Input Port trigger the rule when an I/O port recei ves a signal from a connected device, s ee I/O
Ports, on page 44.
- Manual Trigger trigger the rule using the Manual Trigger button in the Live View page, see Controls on
the Live View page, on page 9 . This c an for ex ample be used to validate actions during product ins tallation
and conguration.
PTZ
- Moving trigger the rule when the camera view mov
es due to a PTZ operation. This c an for example be used
as an additional condition to pre vent an action rule triggered by motion detection to record video while the
camera view moves due to a PTZ operation.
- Preset Reached —triggertherulewhenthecamerastopsatapresetposition.Thiscanbeforexamplebeused
with the Send Images acti
on to upload images from the preset positio n.
Storage
- Available
trigger the rule when the storage device is unmounted or removed. This can for example be
used to send maintenance notications.
- Full trigge r the rule when the storag e device is full. Und er normal operation, the olde st recordings will be
overwritten to prevent the storage device from becoming full.
- Locked
—triggertheruleifthestoragedeviceislocked(writeprotected).
System
- System Initializing trigger the rule when the product is being started. This can for example be used to send a
notication when the pro duct restarts.
Time
- Recurrence trigger the rule periodically, see Recurrences, on page 34. This can for example be used to upload
an image every 5 minutes.
31