Installation Guide

AXISD2110-VESecurityRadar
DigitalinputConnecttopin1toactivate,or
leaveoating(unconnected)todeactivate.
0tomax30VDC Congurable
(Inputor
Output)
3–
6
DigitaloutputInternallyconnectedtopin1(DC
ground)whenactive,andoating(unconnected)
wheninactive.Ifusedwithaninductiveload,e.g.,
arelay,connectadiodeinparallelwiththeload,
toprotectagainstvoltagetransients.
0tomax30VDC,
opendrain,100mA
Example
1
DCground
2
DCoutput12V,max50mA
3
I/Oconguredasinput
4
I/Oconguredasoutput
5
CongurableI/O
6
CongurableI/O
Powerconnector
2-pinterminalblockforDCpowerinput.UseaSafetyExtraLowVoltage(SELV)compliantlimited
powersource(LPS)witheitheraratedoutputpowerlimitedto100Woraratedoutputcurrent
limitedto5A.
18