User's Manual
AXIS M1043–W Network Camera
Hardware overview
Caution
Due to local regulations or the environmental and electrical conditions in which the product is to be use d, a shielded
network cable (STP) may be appropriate or req uired. Any network cables that are routed in outdoor environments or similar
shall be shielded (STP) and intended for their specific use. Make sure that the network switch is properly grounded. See
Electromagnetic Compatibility (EMC)
for regulatory requirements.
Control button - The control button is used for:
• ConnectingtoanAXISVideoHostingSystemservice.See
page 39
. To connect, press and hold the button for about
1 second until the Status LED flashes green.
• ConnectingtoAXISInternetDynamicDNSService. See
page 39
. To connect, press and hold the button for
about 3 seconds.
• Resetting the product to factory default settings. See
page 49
.
WLAN pairing b utton - For connecting to an a ccess point through push button configuration (PBC).
Power connector - Mini DC connector
I/O connector
Note
For technical specifications, see
page 55
.
I/O terminal connector - Use in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications.
In addition to an auxiliary pow e r and a GND pin, the I/O terminal connector provides the interface to:
• Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by
the VAPIX® Application Programming Interface, output buttons on the L
ive View pa g e or by an Action Rule. The
output will show as active (shown under System Options > Ports & Devices) if the alarm device is activated.
• Digital input — An alarm input for connecting device s that can toggle between an open and closed circuit, for
example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and
the input becomes active (shown under System Options > Port
s&Devices).
Function Pin Notes
Specifications
GND
1
Ground
3.3 V DC Power
2
Can be used to power aux iliary equipment.
Note: This pin can only be used as power out.
Max load = 50 mA
Digital Input
3
Connect to GND to activate, or leave floating (unconnected)
to deactivate.
0to+40VDC
Digital Output
4
Internal connection to ground when activated, floating
(unconnected) w
hendeactivated.Ifusedwithaninductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection against voltage transients.
Max load =100 mA
Max voltage = +40
VDC
6