Hardware overview
I/O connector
Note
For technical specications, see page 50.
I/O terminal connector - Use in applications for e.g. m otion detection, event triggering, time lapse recording and alarm notications.
In addition to an auxiliary power and a GND pin, the I/O terminal connector provides the interface to:
Digital output For connecting external devices such as relays and LEDs. Connected devices can be activated by the
VAPIX® Application Programming Interface, output buttons on the Live View page or by an A ction Rule. The o utput will
show as active (shown under System Options > Ports & Devices) if the alarm dev ice is activated.
Digital input An alarm input for connecting devices that can toggle between an open and closed circuit, for example:
PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and the input
becomes active (shown under System Options > Ports & Devices).
Function Pin Notes
Specications
GND
1
Ground
3.3 V DC Power
2
Can be used to power au xiliary equipment.
Note: This pin can only be used as power out.
Max load = 50 mA
Digital Input
3
Connect to GND to activate, or leave oating (unconnected)
to deactivate.
0to+40VDC
Digital O utput
4
Internal connection to ground when activated, oating
(unconnected) when deactivated. If used with an external
relay, a diode must b e connected in parallel with the lo ad, for
protection against v oltage transients.
Max load =100 mA
Max voltage = +40 V DC