INSTALLATION GUIDE AXIS Electrical Safety Kit A 120 V AC ENGLISH AXIS Electrical Safety Kit B 230 V AC FRANÇAIS DEUTSCH ITALIANO ESPAÑOL
Electrical Safety: Low Voltage Directive (LVD) Europe This equipment complies with the Low Voltage Directive 2006/95/EC. Safety For safety information regarding the components of this kit, see Technical Specifications, on page 15. Equipment Modifications This equipment must be installed and used in strict accordance with the instructions given in the user documentation. This equipment contains no user-serviceable components.
Safeguards Please read through this Installation Guide carefully before installing the Axis product. Keep the Installation Guide for further reference. • • • • • • • • This Axis product shall be used in compliance with local laws and regulations. The Axis product should be installed by a trained professional. Observe relevant national and local regulations for the installation.
AXIS Electrical Safety Kit A/B Page 5 AXIS Electrical Safety Kit A/B Installation Guide This Installation Guide provides instructions for installing AXIS Electrical Safety Kit A 120 V AC and AXIS Electrical Safety Kit B 230 V AC in AXIS T98A-VE Surveillance Cabinet Series. Installation steps 1. 2. 3. 4. Check the package contents against the list below. Hardware overview on page 6. Connection diagram on page 7. Install the devices on page 9. • Install the door switch on page 12.
Page 6 AXIS Electrical Safety Kit A/B Hardware Overview 1 2 3 4 5 6 7 1 2 3 4 5 6 7 MCB fuse 4 A (Circuit breaker) Surge protector 4 A Terminal block – feed-through (blue) Terminal block – ground (green/yellow) Terminal block – ground (green/yellow) Door switch Door switch cable In this document PE, Protective Earth, and Ground are referred to as ground.
AXIS Electrical Safety Kit A/B Page 7 Connection Diagram DOOR SWITCH CIRCUIT BREAKER/ FUSE 4 A 5 1 L1 N N1 INCOMING MAINS VOLTAGE L 2 N SURGE PROTECTOR 230 V AC or 120 V AC 3 TO POWER SUPPLIES PE EXTERNAL PROTECTIVE BONDING WIRE 1 2 3 4 5 MCB fuse 4 A (circuit breaker) L Incoming mains voltage N Surge protector PE To power supplies Door switch • 4 PE1 TT - TNS - TNC - IT Line Neutral Protective earth (ground) Ground If an external protective bonding wire is used it is recommended to h
Page 8 • • AXIS Electrical Safety Kit A/B Check the surge protector after lightning strikes and replace if required. See Replace the Surge Protector, on page 14. An additional fuse may be required in regions with severe lightning strikes. To prevent unwanted triggering of the fuse, a higher rated fuse may replace the 4 A MCB fuse, following local regulations. In this case, put the 4 A MCB fuse after the surge protector.
AXIS Electrical Safety Kit A/B Page 9 Install the Devices • • • 1. 2. 3. 4. Keep the wires short but do not stretch them. Short wires give better surge protection than long wires. • The ground wire should be as short as possible and have as large cross section as possible. Attach the ground wire to a suitable grounding point, for example an earth stake. Snap on the fuse, surge protector and terminal blocks on the DIN rail. See Hardware Overview, on page 6 and the examples on page 10.
Page 10 AXIS Electrical Safety Kit A/B Example: AXIS Electrical Safety Kit A 120 V AC 1 2 3 4 5 L PE 1 0 4A N 6 1 2 3 4 5 6 7 8 9 L N 7 8 9 Circuit breaker Surge protector Terminal block – feed-through (blue) Terminal block – ground (green/yellow) Terminal block – ground (green/yellow) Line connection Neutral connection Ground connection External ground connection
AXIS Electrical Safety Kit A/B Page 11 Example: AXIS Electrical Safety Kit B 230 V AC 1 2 3 4 5 L N PE 6 1 2 3 4 5 6 7 8 9 L N 7 8 9 Circuit breaker Surge protector Terminal block – feed-through (blue) Terminal block – ground (green/yellow) Terminal block – ground (green/yellow) Line connection Neutral connection Ground connection External ground connection ENGLISH 1 0 4A
Install the Door Switch The door switch included with the electrical safety kit can be connected to the I/O port on a camera or an I/O device. See the camera’s Installation Guide and User Manual for information about connecting and configuring the camera’s I/O port. 1. Connect either of the connectors on the door switch cable to the common terminal on the door switch.
AXIS Electrical Safety Kit A/B 4. 5. 6. Page 13 If connecting to the I/O port on a camera, route the door switch cable through a cable gasket and attach the cable gasket to one of the cable holes in the cabinet door. Secure the cable to the door using the supplied cable clip. Connect the door switch cable to the I/O port on the camera or the I/O device. 7. Close the cabinet and make sure the switch is activated when the door is closed and released when the door is opened.
Page 14 AXIS Electrical Safety Kit A/B Replace the Surge Protector The surge protector gets worn out by surges. The window on the surge protector shows the status of the device. 1. When the entire window is red, pull out the module and replace it.
AXIS Electrical Safety Kit A/B Page 15 Technical Specifications General Item Specifications General Environment In a casing for indoor or outdoor use Pollution Degree 2 Approvals EN61058 UL1054 Operating conditions -40 ºC to +85 ºC (-40 ºF to 185 ºF) Humidity 15 – 100% RH Approvals UL1059 CSA C22.2 No.
Page 16 AXIS Electrical Safety Kit A/B AXIS Electrical Safety Kit A 120 V AC Function/group Item Specifications Circuit breaker/fuse Rated current 4A at 30°C (86°F) Operating voltage Max 277 V AC Rated frequencey 50/60 Hz Rated short10 kA circuit capacity Surge protective device Tripping curve K Approvals IEC/EN 60947-2 UL 489 CSA 22.2 No.
AXIS Electrical Safety Kit A/B Page 17 AXIS Electrical Safety Kit B 230 V AC Item Specifications Circuit breaker/fuse Rated current 4A at 30°C (86°F) Operating voltage Max 253 V AC Rated frequencey 50/60 Hz Rated short6 kA circuit capacity Surge protective device Tripping curve C Approvals IEC/EN 60898-1 IEC/EN 60947-2 UL 1077 CSA 22.2 No.
Page 18 AXIS Electrical Safety Kit A/B Warranty For information about Axis’ product warranty and thereto related information, see www.axis.
Installation Guide AXIS Electrical Safety Kit A/B © Axis Communications AB, 2012 Ver.2.10 Printed: October 2012 Part No.