User`s manual
6-32
IM 701610-01E
6.13 Setting the Window Trigger (ENHANCED)
<For a description of this function, see page 1-10>
Relevant Keys
ACTION DELAY
X - Y
MENU MENU
PHASE
SEARCH
HORIZONTAL
VERTICAL
TRIGGER
TRIG D
HELP
ESC
SELECTRESET
SIMPLE
MODE POSITION
MATH
MISCFILE
CLEAR
TRACE
HISTORY
MEASURE
SETUP
PRESET
DISPLAY
CURSOR
CH
1
CH
2
CH
3
CH
4
POWER
COPY
IMAGE SAVE
SHIFT
ZOOM
GO/NO-GO
ENHANCED
ACQSTART/STOP
SNAP
SHOT
VDIV TIME DIV
Operating Procedure
Setting the Trigger Type
1. Press ENHANCED.
2. Pressing the Type soft key displays the trigger type menu.
3. Press the OR or Width soft key.
Setting the Window Trigger
4. Press the Window soft key to select ON.
Set the status and trigger conditions of each channel according to the procedures
given in section 6.11, “Setting the Width (Pulse<T, Pulse>T, T1<PLS<T2,
T1<PLS<T2, Time Out)” or 6.12, “Setting the OR Trigger (ENHANCED).”