User`s manual
14-8
IM 701610-01E
14.4 Canceling the Offset Voltage
Relevant Keys
ACTION DELAY
X - Y
MENU MENU
PHASE
SEARCH
HORIZONTAL
VERTICAL
TRIGGER
TRIG D
HELP
ESC
SELECTRESET
SIMPLE
MODE POSITION
MATH
MISCFILE
CLEAR
TRACE
HISTORY
MEASURE
SETUP
PRESET
DISPLAY
CURSOR
CH
1
CH
2
CH
3
CH
4
POWER
COPY
IMAGE SAVE
SHIFT
ZOOM
GO/NO-GO
ENHANCED
ACQSTART/STOP
SNAP
SHOT
VDIV TIME DIV
Operating Procedure
1. Press MISC.
2. Pressing the System Cnfg soft key displays the system configuration menu.
3. Press the Offset Cancel soft key to select ON or OFF.
The default value is OFF.
Explanation
You can select whether or not the offset voltage that is specified for each channel is
reflected in the results of computations and automated measurement of waveform
parameters.
OFF: Does not reflect the offset voltages in the results of computations and automated
measurement of waveform parameters.
The vertical position of the display screen corresponds to the offset voltage.
ON: Reflect the offset voltages in the results of computations and automated
measurement of waveform parameters.
The waveform that has offset voltage (DC voltage) removed from the input signal
can be observed. In this case, the vertical position becomes 0 V.
Note
• Offset cancel applies to all channels.
• To set whether or not to cancel the offset for each channel, use linear scaling.