Technical data

Chapter 3: Remote Operation
3-6 2400 Series Operation Manual, 33237 Revision A, May 2004
3.2.6 Trigger Subsystem
SYSTem:COMMuni-
cate:SERial:SBITS bits
Set RS-232 interface stop bits. Bits = 1, 2
SYSTem:COMMuni-
cate:SERial:SBITS?
Query RS-232 interface stop bits
SYSTem:ERRor[:NEXT]?
Following SCPI error numbers are supported:
-100 COMMAND_ERROR
-113 UNDEFINED_HEADER
-200 EXECUTION_ERROR
-222 DATA_OUT_OF_RANGE
-224 Illegal parameter value
-291 OUT_OF_MEMORY
-350 Error queue overflow.
-400 QUERY_ERROR
Additional error messages are also supported. See Appendix B “2400
Error Messages” on page 1 for a summary of available error messages
SYSTem:LANGuage NATive
Switch from the SCPI command set to the Native command set
SYSTem:LANGuage:NATive <native
cmd>
Issues a Native syntax command for immediate execution from within
SCPI without leaving the SCPI syntax
SYSTem:PRESet
The same as *RST
SYSTem:VERSion?
The response shall have the form 1999.0
Command Description
TRIGger[:IMMediate]
Initiates an immediate sweep cycle in List mode. If Repeat Type is not
set to continuous (single step or single sweep) then the sweep returns
to IDLE when complete
(Same as a *TRG, this is a single instrument trigger, as opposed to a
GroupExecuteTrigger )
TRIGger:SOURce BUS|EXTernal
Selects the trigger source for List mode. The sources are:
BUS: sets to GPIB/GET
EXT: sets to BNC (Trigger commands do not function when in EXT)
TRIGger:SOURce?.
Queries the trigger source for List mode
Command Description